Type B Gasfitting (VIC) key terms
Type B Gasfitting (VIC) · Get comfortable with the vocabulary.
- Type B gas appliance
- Related: Type B gasfitter licence, Commissioning
Gas equipment with a gas consumption rate above the threshold set in Victorian gasfitting regulations, typically 10 megajoules per hour or more, requiring a licensed Type B gasfitter to install, commission or service it.
- Type B gasfitter licence
- Related: Type B gas appliance, Type A gasfitting work
A Victorian licence endorsement authorising the holder to carry out gasfitting work on Type B appliances, gained after a Type A qualification plus further training and assessment in commercial and industrial equipment.
- Type A gasfitting work
- Related: Type B gasfitter licence, Type B gas appliance
Gasfitting on appliances and installations within the lower consumption band, such as domestic cookers, space heaters and storage water heaters, which does not require the additional Type B endorsement.
- Gas installation
- Related: Consumer piping, Commissioning
The complete assembly of pipes, fittings, flues, ventilation and connected appliances supplied with gas from the outlet of the meter or supply point through to each appliance connection.
- Consumer piping
- Related: Gas installation, Pressure test
The pipework downstream of the gas supply point that delivers gas to appliances on the premises, sized and installed so that pressure loss and gas velocity remain within the limits set by the applicable standard.
- Commissioning
- Related: Combustion analysis, Purging, Type B gas appliance
The structured process of proving a newly installed or altered Type B appliance safe and correct, covering purging, ignition, combustion analysis, safety device testing, output verification and recording of results.
- Combustion analysis
- Related: Commissioning, Excess air, Carbon monoxide
Measurement of flue gas oxygen, carbon dioxide, carbon monoxide and temperature to calculate excess air and efficiency, confirming the burner is adjusted to burn cleanly and safely.
- Excess air
- Related: Combustion analysis, Stoichiometric air
The proportion of air supplied beyond that theoretically needed for complete combustion, expressed as a percentage; too little risks carbon monoxide, too much wastes heat up the flue.
- Stoichiometric air
- Related: Excess air, Combustion analysis
The exact quantity of air theoretically required to burn a given amount of gas completely, forming the reference point from which excess air and air-to-gas ratios are calculated.
- Carbon monoxide
- Related: Combustion analysis, Flue spillage
A toxic, odourless gas produced by incomplete combustion; Type B work requires checking flue gases for it and correcting causes such as poor air supply, blocked flues or incorrect gas pressure.
- Flue spillage
- Related: Draught diverter, Carbon monoxide
Combustion products escaping from a draught diverter or flue joint into the occupied space rather than travelling up the flue, typically caused by blocked flues, inadequate draught or depressurisation.
- Draught diverter
- Related: Flue spillage, Flue
A fitting at the appliance flue outlet that separates the combustion system from flue draught variations while allowing spilled products to escape into a ventilated space safely.
- Flue
- Related: Draught diverter, Flue spillage
The duct or passage that carries products of combustion from an appliance to outside air, required to be gas tight, correctly sized, supported and terminated clear of openings and combustible material.
- Gas pressure regulator
- Related: Operating pressure, Test point
A device that reduces and holds gas pressure at a steady value for an appliance or section of piping, protecting burner performance from variations in supply pressure or load.
- Operating pressure
- Related: Gas pressure regulator, Test point
The gas pressure measured at the appliance burner manifold or test point while the appliance runs at its rated input, used to verify correct adjustment and burner performance.
- Test point
- Related: Operating pressure, Pressure test
A capped or plugged tapping on pipework or an appliance where a manometer or gauge is connected to measure pressure during testing, adjustment or fault finding.
- Pressure test
- Related: Consumer piping, Test point
A strength or leak test of new or altered pipework using air, inert gas or gas at a specified pressure for a set period, with results recorded before the installation is commissioned.
- Purging
- Related: Commissioning, Gas installation
Displacing air or inert gas from pipework or an appliance with gas, or displacing gas with air before work, done to controlled procedures so flammable mixtures are not created or released unsafely.
- Safety shut-off valve
- Related: Flame safeguard, Interlock
An automatic valve that closes to cut gas supply when a monitored condition such as flame loss, pressure fault or temperature limit is detected, forming part of an appliance's protective interlock system.
- Flame safeguard
- Related: Safety shut-off valve, Interlock
A system that proves a flame is present and shuts off gas if it is not, using sensing such as flame rectification, thermocouples or ultraviolet detectors with defined response times.
- Interlock
- Related: Safety shut-off valve, Flame safeguard
A control arrangement that prevents or stops burner operation unless conditions such as air flow, ventilation, door position or exhaust operation are proven satisfactory.
- Forced draught burner
- Related: Interlock, Excess air
A burner using a fan to supply combustion air under pressure, requiring proven air flow before ignition and during operation, and typically found on larger commercial and industrial Type B appliances.
- Gas detection system
- Related: Interlock, Hazardous area
Fixed or portable equipment that senses flammable or toxic gas in a plant room or work area and can alarm or initiate shutdown, used to manage risk in Type B plant spaces.
- Hazardous area
- Related: Gas detection system, Ventilation
A zone classified according to the likelihood and duration of a flammable gas atmosphere, which dictates the electrical equipment and ignition sources permitted within it.
- Ventilation
- Related: Hazardous area, Flue spillage
Permanent openings or mechanical air supply and exhaust provided to a plant room or appliance space so combustion air is available and any leaked gas is dispersed safely.
- Gasfitting work
- Related: Type B gasfitter licence, Compliance certificate
Work on gas installations and appliances including installation, alteration, disconnection, servicing, testing and commissioning, which may only be done by or under the supervision of a licensed person.
- Licensing authority
- Related: Type B gasfitter licence, Disciplinary action
The Victorian body that issues gasfitting licences, registrations and endorsements, sets competency requirements and can impose conditions, suspend or cancel a licence.
- Registered gasfitter
- Related: Gasfitting work, Supervision
A person holding a provisional or registered status who may perform gasfitting work only under the supervision of a licensed gasfitter, pending completion of requirements for a full licence.
- Supervision
- Related: Registered gasfitter, Gasfitting work
The required oversight of unlicensed or less qualified workers by a licensed gasfitter who directs, checks and takes responsibility for the work, with the level of oversight depending on the worker's registration.
- Compliance certificate
- Related: Gasfitting work, Notifiable work
A document a licensed gasfitter must give the client and the relevant authority after completing gasfitting work, certifying the work complies with the regulations and applicable standards.
- Notifiable work
- Related: Compliance certificate, Licensing authority
Gasfitting work of a class that must be reported to the relevant authority within a set period, triggering inspection or audit and requiring a compliance certificate.
- Disciplinary action
- Related: Licensing authority, Compliance certificate
Action the licensing authority may take against a licence holder for breaches, unsafe work or misconduct, ranging from conditions and fines to suspension or cancellation of the licence.
- Australian Standard AS/NZS 5601
- Related: Gas installation, Ventilation
The principal standard for gas installations covering design, pipe sizing, ventilation, flueing and appliance connection, referenced by Victorian gasfitting regulations as the technical benchmark.
- Continuing professional development
- Related: Licensing authority, Type B gasfitter licence
Ongoing training and updating that licence holders must complete to keep pace with technical and regulatory change, often required at licence renewal.
- Gas supply point
- Related: Consumer piping, Gas installation
The outlet of the meter or the point where gas is delivered to the premises, marking the boundary between the distributor's assets and the consumer's installation.
- Incident notification
- Related: Compliance certificate, Licensing authority
The duty to promptly report gas leaks, fires, explosions, injuries or dangerous occurrences arising from gasfitting work to the regulator and emergency services.
- Asbestos and hazardous materials awareness
- Related: Hazardous area, Commissioning
Recognition of asbestos, lead and other hazardous materials likely in older gas installations and flues, and the controls required before disturbing them during Type B work.
- Lockout and tagout
- Related: Safety shut-off valve, Purging
Isolating gas and electrical energy and fitting a personal lock and tag so equipment cannot be energised while servicing or repair is in progress.