AZ Plumber study materials
AZ Plumber study resources

AZ Plumber cheat sheet

AZ Plumber · Keep the key ideas within reach.

Quick reference

General Regulations, Code Administration, and Licensing

  • Permits are required before installing, altering, replacing, or repairing plumbing systems; ordinary minor repairs and stoppage clearing are typically exempt.

  • A permit application must identify the scope of work, the licensed contractor, and the responsible master plumber; work may not start before permit issuance.

  • Inspections occur at defined stages: rough-in (before concealment), top-out, and final; concealed work must be approved before covering.

  • Licensing is tiered (apprentice, journeyman, master); only a master or qualifying license holder may pull permits and contract plumbing work.

  • Code editions are adopted by local ordinance; when editions conflict, the locally adopted edition and amendments govern.

  • A stop-work order may be issued for work without a permit or work that is unsafe; work resumes only after compliance.

  • Continuing education hours and license renewal cycles are set by the licensing board; lapsed licenses may not be used to obtain permits.

  • Unsafe or noncompliant installations may be red-tagged, requiring disconnection or correction before service is restored.

Quick reference

Piping Materials, Fittings, Joints, and Supports

  • Copper tube types differ by wall thickness: K thickest, then L, M, thinnest; type M is restricted to some above-ground uses.

  • Potable water piping must be lead-free; solder and flux must be lead-free, and lead content in wetted surfaces is limited to 0.25 percent.

  • PVC and ABS are joined with solvent cement matched to pipe material; CPVC requires cement rated for CPVC.

  • PEX is joined by ASTM F1807/F2159 fittings (crimp or press); PEX cannot be solvent cemented and needs UV or sleeving protection where exposed.

  • Cast iron soil pipe joins by hub-and-spigot with gaskets or no-hub couplings; no-hub couplings require band torque per manufacturer.

  • Support spacing depends on pipe material and diameter; copper typically supports at about 6 ft for 1-inch and smaller horizontal runs.

  • Horizontal drainage pipe must slope at 1/4 inch per foot for 2-inch and smaller, 1/8 inch per foot for 3-inch and larger where allowed.

  • Dielectric unions or insulating bushings separate dissimilar metals to prevent galvanic corrosion at copper-to-steel connections.

Quick reference

Plumbing Fixtures, Fixture Fittings, and Fixture Traps

  • Water closets are limited to 1.6 gallons per flush; urinals to 1.0 gpf; kitchen faucets to 2.2 gpm at 60 psi; showerheads to 2.5 gpm at 80 psi.

  • Each fixture must have a trap, except fixtures with integral traps and pairs of fixtures that drain through a single trap where permitted.

  • A fixture trap seal must be at least 2 inches and at most 4 inches deep; trap arms have developed-length limits based on pipe size.

  • A water closet must be set level and secured to the flange; the closet flange must be fastened to the floor and connect to the drain.

  • Fixture outlets must be protected by an air gap or backflow device where a fixture could back up into the supply.

  • Floor drains require a trap with a seal; trap primers are used where the seal would evaporate.

  • Accessible fixtures must meet reach range and clearance requirements; lavatories require a knee clearance and insulated drain.

  • Fixture clearances are enforced: water closets need 15 inches from centerline to side wall and 30 inches of width.

Quick reference

Water Supply and Distribution Systems

  • Residual pressure must be maintained at fixtures; common minimum is 8 psi at the fixture under flow, with 20 psi at the street main.

  • Sizing uses fixture units converted to demand (gpm); the building supply must deliver peak demand within allowable pressure loss.

  • Thermal expansion in a closed system requires an expansion tank or a device to relieve pressure.

  • A water service must be protected from backflow with a device appropriate to the hazard, such as an RPZ for high hazard.

  • Shutoff valves are required on the service and at each fixture group; drains allow the system to be emptied.

  • Water hammer arrestors are placed near quick-closing valves such as flushometers and solenoid appliances.

  • Hot water distribution should limit dead legs; recirculation keeps hot water within a reasonable time at fixtures.

  • Piping must be protected from freezing; exposed supply lines in unheated spaces require insulation and heat tracing where needed.

Quick reference

Sanitary Drainage, Venting, and Storm Drainage

  • Drainage systems use gravity flow; slope is 1/4 inch per foot for 2-inch and smaller and 1/8 inch per foot for 3-inch and larger.

  • A building drain is the lowest piping that receives soil and waste; the building sewer extends from the building to the public sewer.

  • Vent stacks must extend at least 6 inches above the roof or to a required height above the roof surface.

  • Each trap must be vented, and the vent must rise at least 6 inches above the fixture's flood level rim before offsetting.

  • A wet vent is a vent that also serves as a drain; wet vent sizing and length are limited by the code.

  • Storm drainage must be kept separate from sanitary drainage unless combined systems are approved.

  • Cleanouts are required at the base of stacks, at changes of direction greater than 45 degrees, and at intervals along horizontal runs.

  • Drainage fixture units are assigned by fixture type and must not exceed the pipe capacity for the chosen diameter and slope.

Quick reference

Traps, Interceptors, Backflow Prevention, and Cross-Connection Control

  • A trap seal is maintained by a vent; the vent prevents siphonage and backpressure from breaking the seal.

  • Grease interceptors are required for food service fixtures that discharge grease-laden waste; they must be accessible for cleaning.

  • A backflow preventer must be selected by hazard level: air gaps for high hazard, RPZ for high hazard, DCVA for low hazard.

  • An air gap is the only absolute protection; it requires a physical separation of at least twice the effective opening.

  • A cross-connection is any actual or potential connection between potable and nonpotable systems; it must be eliminated or protected.

  • Backflow assemblies require annual testing by a certified tester and records retained for the authority.

  • A trap primer maintains the seal of a floor drain trap that would otherwise evaporate.

  • Interceptors must be vented and installed with a cleanout and access for maintenance.

Quick reference

Water Heaters, Temperature Control, and Thermal Expansion

  • A temperature and pressure relief valve is required on every storage water heater; it must be rated for the heater's capacity.

  • The T&P relief discharge must terminate within 6 inches of the floor or outside, and must not be trapped or reduced.

  • A thermal expansion tank is required on a closed system to absorb expansion from heating.

  • A water heater must be secured against seismic movement where required, with strapping at the upper and lower thirds.

  • Hot water at fixtures must not exceed 120 degrees F for domestic use; scald protection is required at bathing fixtures.

  • A water heater in a garage must be elevated so the ignition source is at least 18 inches above the floor.

  • Combustion air and venting must follow the manufacturer's instructions and the gas code; a draft hood must be properly connected.

  • A drain pan is required where leakage could cause damage; the pan drain must terminate to an approved location.

Quick reference

Fuel Gas Piping and Gas Appliance Connections

  • Gas piping must be sized for the connected load and allowable pressure drop; the longest run method is commonly used.

  • Black steel pipe is joined by threaded fittings; approved sealant must be applied to male threads only, leaving the first two threads bare.

  • A sediment trap is required at each appliance connection, installed downstream of the appliance shutoff valve.

  • A gas shutoff valve must be installed ahead of each appliance and be accessible.

  • Gas piping must be tested with air or inert gas; typical test pressure is 10 psi for at least 30 minutes for low-pressure systems.

  • Gas piping must not be concealed in a way that prevents inspection; joints must be accessible unless approved.

  • A gas appliance connector must be listed and not exceed 6 feet for a movable appliance.

  • Combustion air must be provided per the gas code; a confined space requires two openings sized to the appliance input.

Quick reference

Isometric Drawings, Plan Reading, and System Layout

  • An isometric drawing shows three axes at 30 degrees from horizontal, giving a 3D view of a piping run.

  • Plan view shows the layout from above; elevation shows vertical relationships; sections show internal construction.

  • Riser diagrams show vertical stacks and their connections; they do not show horizontal distances to scale.

  • A plumbing plan uses symbols for fixtures, valves, and pipe materials; a legend defines each symbol.

  • Drainage is drawn with slope in the direction of flow; arrows indicate flow direction.

  • Dimension lines indicate pipe lengths and fixture spacing; check scale before measuring from a drawing.

  • A bill of materials or schedule lists pipe sizes, fixture types, and quantities for takeoff.

  • Coordination with structural and mechanical drawings prevents conflicts such as beams crossing pipe runs.

Quick reference

Safety, Tools, and Job-Site Practices

  • Before digging, call 811 to locate underground utilities; hand-dig near marked lines.

  • Personal protective equipment includes eye protection, gloves, and hearing protection when cutting or using power tools.

  • Confined space entry requires atmospheric testing, a permit, an attendant, and rescue equipment.

  • A pipe wrench is sized to the pipe; a strap wrench is used on finished surfaces to avoid damage.

  • Soldering requires ventilation and a fire watch; a heat shield protects combustibles from the torch.

  • Ladders must be set at a 4:1 slope; three points of contact are maintained while climbing.

  • Lockout/tagout is required before servicing equipment with stored energy.

  • Scaffolding must be fully planked and have guardrails; fall protection is required above the trigger height.