Permit requirement
A permit is required before installing, altering, or replacing plumbing work; minor repairs and stoppage clearing are typically exempt, and inspections follow at rough-in and final stages.
Master plumber role
A master or qualifying license holder may pull permits and contract plumbing work; apprentices and journeymen work under supervision and may not contract independently.
Stop-work order
An official order halting work that lacks a permit or is unsafe; work may resume only after the violation is corrected and the authority approves.
Copper tube types
Type K is thickest, followed by L and M; type M is thinnest and is limited in some jurisdictions to above-ground or nonconcealed use.
Lead-free requirement
Potable water piping, solder, and flux must be lead-free; wetted surfaces are limited to 0.25 percent lead by weight.
No-hub coupling
A cast iron soil pipe coupling with a neoprene sleeve and metal shield, tightened to the manufacturer's torque to join pipe without hubs.
Drainage slope rule
Horizontal drainage pipe slopes at 1/4 inch per foot for 2-inch and smaller, and 1/8 inch per foot for 3-inch and larger where permitted.
Dielectric union
An insulating fitting placed between copper and steel piping to interrupt galvanic current and prevent corrosion at the dissimilar metal joint.
Water closet flush limit
Water closets are limited to 1.6 gallons per flush; urinals are limited to 1.0 gallon per flush under current efficiency standards.
Trap seal depth
A fixture trap seal must be at least 2 inches and at most 4 inches deep to resist siphonage while allowing waste to pass.
Closet flange
A flange fastened to the floor and connected to the drain that receives the water closet and secures it in a watertight joint.
Accessible lavatory
A lavatory must provide knee clearance, an insulated drain, and controls within reach range to meet accessibility requirements.
Residual pressure
The pressure remaining at a fixture under flow; systems are sized so fixtures maintain a minimum residual, commonly 8 psi.
Fixture unit sizing
Fixture units are converted to demand in gallons per minute; the building supply is sized to deliver peak demand within allowable pressure loss.
Water hammer arrestor
A device installed near quick-closing valves to absorb the pressure surge caused by sudden stoppage of water flow.
Building drain
The lowest piping that receives soil and waste inside the building and conveys it to the building sewer at or outside the foundation.
Vent stack height
A vent stack must extend at least 6 inches above the roof surface, or higher where snow or other conditions require.
Wet vent
A vent that also serves as a drain for fixtures; its size and length are limited by code to prevent trap seal loss.
Cleanout location
Cleanouts are required at the base of stacks, at direction changes greater than 45 degrees, and at intervals along horizontal drains.
Air gap
The only absolute backflow protection; it requires a physical separation of at least twice the effective opening of the supply outlet.
RPZ device
A reduced pressure zone backflow assembly used for high-hazard protection; it requires annual testing by a certified tester.
Grease interceptor
A device that traps grease-laden waste from food service fixtures before it enters the drainage system; it must be accessible for cleaning.
Cross-connection
Any actual or potential connection between potable water and a nonpotable source that could allow contamination to enter the drinking water system.
T&P relief valve
A temperature and pressure relief valve required on storage water heaters; its discharge must terminate safely and must not be trapped or reduced.
Thermal expansion tank
A tank installed on a closed water system to absorb the volume increase caused by heating water and prevent excessive pressure.
Garage water heater
A water heater in a garage must be elevated so the ignition source is at least 18 inches above the floor to avoid flammable vapor ignition.
Sediment trap
A dirt pocket installed at each gas appliance connection, downstream of the shutoff valve, to catch debris before it reaches the controls.
Gas piping test
Gas piping is tested with air or inert gas; low-pressure systems commonly require 10 psi held for at least 30 minutes without pressure loss.
Gas connector limit
A listed gas appliance connector must not exceed 6 feet for a movable appliance and must not pass through walls or floors.
Isometric drawing
A drawing with three axes at 30 degrees from horizontal that shows a piping system in three dimensions for layout and takeoff.
Riser diagram
A schematic showing vertical stacks and their connections; it indicates relative elevations but is not drawn to horizontal scale.
Utility locate call
Before digging, call 811 to have underground utilities marked; hand-dig near marked lines to avoid damaging gas, water, or electric lines.