Barbados Wireman Licence Exam key terms
Barbados Wireman Licence Exam · Get comfortable with the vocabulary.
- Ohm's law
- Related: Voltage drop, Impedance
The fixed relationship in a circuit stating that current equals voltage divided by resistance, so a higher voltage pushes more current and a higher resistance allows less.
- Impedance
- Related: Ohm's law, Power factor
The total opposition a circuit offers to alternating current, combining resistance with reactance so that current and voltage may not rise and fall together.
- Power factor
- Related: Impedance, Volt-ampere
The ratio of real power doing useful work to the total apparent power supplied, expressed as a decimal or percentage and reduced by inductive or capacitive loads.
- Voltage drop
- Related: Ohm's law, Conductor ampacity
The reduction in voltage along a conductor caused by its resistance and the current flowing through it, calculated from conductor size, length and load current.
- Conductor ampacity
- Related: Derating factor, Voltage drop
The maximum continuous current a conductor can carry under stated installation conditions without its insulation exceeding its rated temperature limit.
- Derating factor
- Related: Conductor ampacity, Correction factor for ambient temperature
A multiplier applied to a cable's tabulated current rating to account for conditions such as grouping, high ambient temperature or thermal insulation that reduce its ability to shed heat.
- Correction factor for ambient temperature
- Related: Derating factor, Conductor ampacity
A multiplier used when the surrounding air or ground is hotter or colder than the reference temperature assumed in the current-carrying table for that cable type.
- Diversity factor
- Related: Maximum demand, Consumer unit
The assumption that not all connected loads operate at full demand simultaneously, allowing the maximum demand of an installation to be assessed as less than the total connected load.
- Maximum demand
- Related: Diversity factor, Service entrance
The greatest load, usually averaged over a set period, that an installation or circuit is expected to draw, used to size service conductors and protective devices.
- Earthing
- Related: Bonding, Earth electrode resistance, Protective conductor
Connecting exposed metalwork and the installation's protective conductors to the general mass of earth so that fault current has a low-impedance path back to the supply source.
- Bonding
- Related: Earthing, Main earthing terminal, Equipotential bonding
Permanently joining metal parts together, or to the earthing system, so they remain at substantially the same potential and cannot develop a dangerous voltage between them.
- Equipotential bonding
- Related: Bonding, Main earthing terminal
Connecting all simultaneously accessible metalwork, including incoming metallic services, so that no hazardous potential difference can appear between them during a fault.
- Main earthing terminal
- Related: Earthing, Protective conductor, Equipotential bonding
The common bar or block in an installation to which the earthing conductor, circuit protective conductors and main bonding conductors are all connected.
- Protective conductor
- Related: Earthing, Circuit protective conductor, Main earthing terminal
A conductor provided specifically to carry fault current or to connect exposed metalwork to earth, commonly called the earth wire in a circuit cable.
- Circuit protective conductor
- Related: Protective conductor, Earth fault loop impedance
The protective conductor connecting exposed conductive parts of a final circuit back to the main earthing terminal, ensuring fault current trips the protective device quickly.
- Earth electrode resistance
- Related: Earthing, Earth fault loop impedance
The resistance between an earth electrode and the surrounding ground, which must be low enough for protective devices to operate and for touch voltages to stay safe.
- Earth fault loop impedance
- Related: Circuit protective conductor, Earth electrode resistance, Disconnection time
The total impedance of the path taken by fault current from the source, through the live conductor, the fault, the protective conductor and back to the source.
- Disconnection time
- Related: Earth fault loop impedance, Residual current device
The maximum permitted interval within which a protective device must automatically cut off supply after a fault, set by regulation according to circuit type and voltage.
- Residual current device
- Related: Disconnection time, Miniature circuit breaker, RCD test
A protective device that continuously compares live and neutral currents and trips when their difference, representing leakage to earth, exceeds its rated residual operating current.
- Miniature circuit breaker
- Related: Residual current device, Fuse rating, Breaking capacity
A manually resettable automatic switch that opens on overload or short circuit, rated by its nominal current and its breaking capacity.
- Fuse rating
- Related: Miniature circuit breaker, Breaking capacity
The current a fuse is designed to carry continuously without melting, together with its fusing factor that determines how quickly it operates at higher currents.
- Breaking capacity
- Related: Miniature circuit breaker, Prospective fault current
The maximum prospective fault current a protective device can safely interrupt without damage or dangerous arcing, sometimes called short-circuit capacity.
- Prospective fault current
- Related: Breaking capacity, Earth fault loop impedance
The current that would flow at a given point if a short circuit of negligible impedance occurred there, calculated from supply voltage and circuit impedance.
- Insulation resistance test
- Related: Continuity test, Polarity test, RCD test
A test applying a steady direct voltage between conductors and earth to confirm insulation is sound, with results recorded in megohms and compared against a minimum acceptable value.
- Continuity test
- Related: Insulation resistance test, Polarity test, Ring final circuit
A low-resistance check confirming that protective conductors, bonding conductors and ring final circuit conductors form an unbroken, properly connected path.
- Polarity test
- Related: Continuity test, Insulation resistance test
A verification that line, neutral and protective conductors are connected to the correct terminals throughout the installation, so switches and fuses are in the live conductor.
- RCD test
- Related: Residual current device, Disconnection time
An instrument check confirming a residual current device trips within its rated residual current and permitted time, including verification of its test button operation.
- Ring final circuit
- Related: Continuity test, Consumer unit
A socket-outlet circuit whose conductors form a closed loop from the consumer unit, allowing each leg to share the load and requiring continuity verification of all conductors.
- Consumer unit
- Related: Maximum demand, Ring final circuit, Service entrance
The enclosure at the origin of a domestic or small commercial installation housing the main switch, protective devices and earthing and bonding terminals for final circuits.
- Service entrance
- Related: Consumer unit, Maximum demand, Earthing
The point where the supply authority's conductors enter the premises, including the meter position, main switch and the origin of the installation's earthing arrangements.
- Volt-ampere
- Related: Power factor, Impedance
The unit of apparent power in an alternating current circuit, equal to the product of root-mean-square voltage and current without regard to phase difference.
- Cable gland
- Related: Cable tray, Ingress protection rating
A fitting that secures a cable where it enters an enclosure and, where required, provides strain relief and electrical continuity between cable armour and the enclosure.
- Ingress protection rating
- Related: Cable gland, Cable tray
A two-digit code stating how well an enclosure resists entry of solid objects and water, used to select equipment suitable for the environment where it is installed.
- Cable tray
- Related: Cable gland, Ingress protection rating
A support system of perforated or ladder-section metal on which cables are laid, requiring correct spacing, fixing and earthing of the tray itself.
- Method statement
- Related: Risk assessment, Permit to work, Isolation and lock-off
A written description of how a particular job will be carried out safely, listing the sequence of work, the hazards identified and the controls to be applied.
- Risk assessment
- Related: Method statement, Permit to work
A careful examination of what in the work could cause harm, evaluating how likely and how serious that harm is and deciding what precautions are reasonably practicable.
- Isolation and lock-off
- Related: Permit to work, Method statement, Proving dead
The procedure of switching off, proving dead, and securing the supply with locks and warning tags so that equipment cannot be re-energised while work proceeds.
- Proving dead
- Related: Isolation and lock-off, Permit to work
Testing an isolated circuit with a proven voltage indicator at the point of work to confirm no dangerous voltage is present before touching conductors.
- Permit to work
- Related: Isolation and lock-off, Method statement, Risk assessment
A formal written authorisation issued for high-risk work, recording the isolation applied, the precautions taken and the person authorised to carry out the task.
- Electrical installation certificate
- Related: Minor works certificate, Periodic inspection report, Schedule of test results
The formal document issued on completion of new work or a major alteration, declaring the design, construction, inspection and testing comply with the wiring regulations.
- Minor works certificate
- Related: Electrical installation certificate, Schedule of test results
A shorter certificate used for small additions or alterations that do not include a new circuit, covering the work done and the tests carried out on it.
- Periodic inspection report
- Related: Electrical installation certificate, Schedule of test results
A report produced after inspecting and testing an existing installation at planned intervals, recording its condition, defects found and any recommended remedial action.
- Schedule of test results
- Related: Electrical installation certificate, Insulation resistance test, Earth fault loop impedance
The accompanying record listing each circuit's protective device, conductor sizes, and measured insulation resistance, continuity, loop impedance and RCD trip times.