BCS Written EEE (892) study materials
BCS Written EEE (892) study resources

BCS Written EEE (892) cheat sheet

BCS Written EEE (892) · Keep the key ideas within reach.

Quick reference

Electrical Circuits and Network Analysis

  • Ohm's law: V = IR; power P = VI = I²R = V²/R for a resistor.

  • Kirchhoff's current law (KCL): algebraic sum of currents at a node is zero; Kirchhoff's voltage law (KVL): algebraic sum of voltages around a closed loop is zero.

  • Thevenin's theorem: any linear two-terminal network can be replaced by an equivalent voltage source V_th in series with R_th, where V_th is the open-circuit voltage and R_th is the resistance seen with independent sources deactivated.

  • Norton's theorem: equivalent current source I_N in parallel with R_N; I_N is the short-circuit current and R_N = R_th.

  • Superposition applies only to linear circuits: response = sum of responses to each independent source acting alone with others deactivated (voltage sources shorted, current sources opened).

  • Maximum power transfer to a load occurs when R_L = R_th (DC) or Z_L = Z_th* (AC); efficiency at maximum power transfer is 50% for a resistive DC source.

  • First-order RC circuit: time constant τ = RC; capacitor voltage v_C(t) = V_∞ + (V_0 − V_∞)e^(−t/τ). RL circuit: τ = L/R; inductor current i_L(t) = I_∞ + (I_0 − I_∞)e^(−t/τ).

  • RLC series resonance: f_0 = 1/(2π√(LC)); quality factor Q = (1/R)√(L/C) = f_0/BW; bandwidth BW = f_0/Q.

  • Two-port network parameters: z-parameters V1 = z11 I1 + z12 I2, V2 = z21 I1 + z22 I2; for a reciprocal network z12 = z21.

Quick reference

Electrical Machines and Transformers

  • DC machine EMF: E = (PΦNZ)/(60A), where P = poles, Φ = flux per pole, N = speed in rpm, Z = total armature conductors, A = number of parallel paths (A = P for lap, A = 2 for wave).

  • DC motor torque: T = (PΦI_a Z)/(2πA) = 9.55 × P_out/N (N·m); back EMF E_b = V − I_a R_a.

  • Transformer EMF equation: E = 4.44 f N Φ_m; turns ratio a = N1/N2 = V1/V2 ≈ I2/I1.

  • Transformer equivalent circuit: referred secondary impedance to primary is multiplied by a²; core-loss resistance R_c represents hysteresis and eddy-current losses; magnetizing reactance X_m represents magnetizing current.

  • Induction motor synchronous speed: N_s = 120f/P; slip s = (N_s − N_r)/N_s; rotor frequency f_r = s f.

  • Three-phase induction motor torque: T = (3/ω_s) × [s E_2² R_2 / (R_2² + (s X_2)²)] referred to stator; maximum torque occurs at s = R_2/X_2.

  • Synchronous machine: E_f = V_t + j I_a X_s (cylindrical rotor, per phase, neglecting R_a); power P = (3 V_t E_f / X_s) sin δ.

  • Transformer losses: copper loss = I²R (varies with load squared); core loss is approximately constant at rated voltage and frequency; efficiency is maximum when copper loss equals core loss.

Quick reference

Power Systems (Generation, Transmission, Distribution, Protection)

  • Per-unit system: Z_pu = Z_actual / Z_base; Z_base = V_base² / S_base (three-phase); change of base: Z_pu,new = Z_pu,old × (S_new/S_old) × (V_old/V_new)².

  • Short transmission line (length < 80 km): ABCD parameters A = D = 1, B = Z, C = 0; medium line (80–250 km) uses nominal-π or nominal-T model.

  • Surge impedance of a lossless line: Z_c = √(L/C); surge impedance loading SIL = V_L² / Z_c.

  • Power flow on a short line: P = (V_s V_r / X) sin δ; Q = (V_s V_r / X) cos δ − V_r²/X; maximum power at δ = 90°.

  • Symmetrical components: positive, negative, and zero sequence; a = 1∠120°; I_a0 = (I_a + I_b + I_c)/3; zero-sequence currents require a neutral return path.

  • Protection: overcurrent relay coordination uses time-multiplier settings; distance relay zones: Zone 1 ≈ 80% of line, Zone 2 ≈ 120–150%, Zone 3 covers remote backup.

  • Circuit breaker rating: symmetrical interrupting current plus DC component; making current peak = 2.55 × symmetrical rms for a fully offset wave.

  • Transmission line voltage regulation = (|V_r,noload| − |V_r,fullload|)/|V_r,fullload| × 100%; Ferranti effect raises receiving-end voltage on lightly loaded long lines.

Quick reference

Power Electronics and Drives

  • Thyristor conduction: triggered by gate current when forward-biased; turns off when anode current falls below holding current; latching current is the current needed to keep it on immediately after turn-on.

  • Single-phase fully controlled bridge with resistive load: V_dc = (2V_m/π) cos α; with highly inductive load and freewheeling diode, V_dc = (2V_m/π) cos α for 0 ≤ α ≤ 90°.

  • Three-phase fully controlled bridge: V_dc = (3√3 V_m/π) cos α = 1.35 V_LL cos α (where V_LL is line-to-line rms).

  • Buck converter (continuous conduction): V_o = D V_s; boost converter: V_o = V_s/(1 − D); buck-boost: V_o = −V_s D/(1 − D).

  • DC motor speed control: N ∝ (V_a − I_a R_a)/Φ; armature voltage control gives constant-torque operation below base speed; field weakening gives constant-power operation above base speed.

  • Induction motor variable-frequency drive: V/f control maintains constant flux below base speed; above base speed, voltage is held constant and flux weakens.

  • PWM inverter: modulation index m = V_control/V_triangle; fundamental output voltage (linear region, m ≤ 1) V_1 = m V_dc/2 for a half-bridge; for a full bridge V_1 = m V_dc.

  • Snubber circuits protect switching devices: RC snubber across a thyristor limits dv/dt; a series inductor limits di/dt.

Quick reference

Control Systems and Instrumentation

  • Transfer function G(s) = Y(s)/U(s) for zero initial conditions; closed-loop transfer function with unity feedback is G/(1 + G).

  • Second-order system: ω_n = natural frequency, ζ = damping ratio; characteristic equation s² + 2ζω_n s + ω_n² = 0; percent overshoot = 100 e^(−ζπ/√(1−ζ²)); settling time (2%) ≈ 4/(ζω_n).

  • Routh–Hurwitz criterion: number of sign changes in the first column of the Routh array equals the number of right-half-plane poles.

  • Steady-state error: for a step input, e_ss = 1/(1 + K_p); ramp input, e_ss = 1/K_v; parabolic input, e_ss = 1/K_a, where K_p = lim_{s→0} G(s), K_v = lim_{s→0} sG(s), K_a = lim_{s→0} s²G(s).

  • Bode plot: gain margin = negative of the gain (dB) at the phase crossover frequency (phase = −180°); phase margin = 180° + phase at the gain crossover frequency (gain = 0 dB).

  • PID controller: u(t) = K_p e(t) + K_i ∫e dt + K_d de/dt; integral action eliminates steady-state error; derivative action increases damping and reduces overshoot.

  • Strain gauge: gauge factor GF = (ΔR/R)/(ΔL/L); Wheatstone bridge converts resistance change to voltage; quarter-bridge output V_o ≈ (V_ex/4) × GF × ε.

  • Instrumentation: accuracy = closeness to true value; precision = repeatability; resolution = smallest detectable change; a 3½-digit DMM has 1999 counts.

Quick reference

Electronic Devices, Circuits and Analog Electronics

  • PN-junction diode: Shockley equation I_D = I_s(e^(V_D/(nV_T)) − 1); thermal voltage V_T ≈ 26 mV at 300 K; forward drop ≈ 0.7 V for silicon, 0.3 V for germanium.

  • BJT regions: cutoff (V_BE < 0.7 V), active (V_BE ≈ 0.7 V, V_CE > 0.2 V), saturation (V_CE ≈ 0.2 V); β = I_C/I_B; α = β/(1 + β).

  • MOSFET: in saturation, I_D = ½ k_n (V_GS − V_th)² (with channel-length modulation neglected); in triode, I_D = k_n[(V_GS − V_th)V_DS − V_DS²/2].

  • Op-amp ideal assumptions: infinite open-loop gain, infinite input impedance, zero output impedance; virtual short (V+ = V−) applies with negative feedback.

  • Inverting amplifier gain = −R_f/R_in; non-inverting gain = 1 + R_f/R_in; integrator: V_o = −(1/RC)∫V_i dt; differentiator: V_o = −RC dV_i/dt.

  • Common-emitter amplifier: voltage gain ≈ −g_m R_C (or −R_C/r_e); input resistance ≈ β r_e; output resistance ≈ R_C.

  • Rectifiers: half-wave V_dc = V_m/π; full-wave V_dc = 2V_m/π; ripple factor for capacitor-filtered full-wave rectifier ≈ 1/(4√3 f C R_L).

  • Zener regulator: series resistor R_s = (V_in − V_Z)/(I_Z + I_L); Zener must remain reverse-biased above V_Z.

Quick reference

Digital Electronics

  • Boolean identities: A + A'B = A + B; A + AB = A; De Morgan: (A + B)' = A'B', (AB)' = A' + B'.

  • Karnaugh map grouping: groups must contain 1, 2, 4, 8, … adjacent cells; larger groups yield simpler terms; don't-cares may be included to enlarge groups.

  • Combinational building blocks: 2-to-1 multiplexer F = S' I_0 + S I_1; 1-bit full adder S = A ⊕ B ⊕ C_in, C_out = AB + AC_in + BC_in.

  • Flip-flops: D flip-flop Q(next) = D; JK flip-flop Q(next) = JQ' + K'Q; T flip-flop toggles when T = 1.

  • Number systems: binary-to-decimal by positional weights; hexadecimal digit = 4 bits; BCD uses 4 bits per decimal digit; Gray code changes one bit between adjacent codes.

  • Signed number representations: two's complement range for n bits is −2^(n−1) to 2^(n−1) − 1; negation is bitwise complement plus 1.

  • Sequential circuit design: state diagram → state table → state assignment → excitation table → K-map simplification → flip-flop inputs.

  • Memory: ROM is nonvolatile; RAM is volatile; address lines m give 2^m locations; data lines n give word width n bits.

Quick reference

Microprocessors and Embedded Systems

  • 8085 microprocessor: 8-bit data bus, 16-bit address bus, 64 KB address space; clock 3 MHz; registers A, B, C, D, E, H, L; flags S, Z, AC, P, CY.

  • 8086 microprocessor: 16-bit data bus, 20-bit address bus, 1 MB address space; memory segmented into 64 KB segments; physical address = segment × 16 + offset.

  • Instruction cycle phases: fetch, decode, execute; machine cycle consists of T-states; 8085 instruction timing given in T-states (e.g., MOV r, r = 4 T-states).

  • Interrupts: 8085 has TRAP (highest priority), RST 7.5, 6.5, 5.5, INTR (lowest); vectored interrupts have fixed addresses.

  • Memory-mapped I/O uses the same address space as memory; port-mapped I/O uses separate IN/OUT instructions and port addresses.

  • Embedded system characteristics: dedicated function, real-time constraints, limited memory and power; common architectures include ARM Cortex-M and AVR.

  • Serial protocols: UART asynchronous with start/stop bits; SPI synchronous full-duplex with master/slave and chip select; I²C two-wire (SDA, SCL) with addressing.

  • Watchdog timer resets the processor if firmware fails to clear it within a set interval, preventing lock-up in embedded systems.

Quick reference

Communication Systems and Signal Processing

  • AM: modulation index μ = A_m/A_c; total power P_t = P_c(1 + μ²/2); bandwidth = 2 f_m; DSB-SC and SSB bandwidths are 2 f_m and f_m respectively.

  • FM: modulation index β = Δf/f_m; Carson's rule bandwidth ≈ 2(Δf + f_m); FM improves noise immunity at the cost of bandwidth.

  • Shannon–Hartley capacity: C = B log₂(1 + S/N) bits/s; Nyquist sampling rate f_s ≥ 2 f_max to avoid aliasing.

  • PCM: quantization noise power = Δ²/12; signal-to-quantization-noise ratio (SQNR) ≈ 6.02 n + 1.76 dB for a full-scale sinusoid with n bits.

  • Digital modulation: BPSK and QPSK have the same bit-error-rate performance in AWGN (QPSK carries two bits per symbol); 16-QAM requires higher SNR for the same BER.

  • DFT: X[k] = Σ_{n=0}^{N−1} x[n] e^(−j2πkn/N); FFT reduces computation from O(N²) to O(N log₂ N).

  • LTI systems: convolution in time equals multiplication in frequency; a system is stable if its impulse response is absolutely summable (BIBO stability).

  • Antenna: half-wave dipole length ≈ 0.5λ; free-space wavelength λ = c/f; Friis transmission equation P_r = P_t G_t G_r (λ/(4πd))².

Quick reference

Computer Networks, Software and ICT Applications

  • OSI seven layers (bottom up): Physical, Data Link, Network, Transport, Session, Presentation, Application; TCP/IP model merges Session, Presentation, and Application into Application.

  • IPv4 address: 32 bits, dotted decimal; private ranges 10.0.0.0/8, 172.16.0.0/12, 192.168.0.0/16; subnet mask /24 gives 254 usable hosts.

  • TCP is connection-oriented and reliable with three-way handshake (SYN, SYN-ACK, ACK); UDP is connectionless and unreliable with lower overhead.

  • Ethernet CSMA/CD: minimum frame size 64 bytes; maximum 1518 bytes with VLAN tag; MAC address is 48 bits.

  • Routing: distance-vector protocols (RIP) use hop count; link-state protocols (OSPF) use Dijkstra's algorithm; BGP is the inter-domain routing protocol.

  • Software engineering: waterfall is sequential; agile uses iterative sprints; version control (Git) tracks changes with commits, branches, and merges.

  • ICT applications: databases use SQL for relational queries; cloud service models are IaaS, PaaS, SaaS; virtualization abstracts hardware resources.

  • Network security: symmetric encryption (AES) uses one shared key; asymmetric encryption (RSA) uses public/private key pairs; hashing (SHA-256) provides integrity.

Quick reference

Engineering Mathematics and Quantitative Methods

  • Laplace transforms: L{1} = 1/s, L{e^(−at)} = 1/(s+a), L{sin ωt} = ω/(s²+ω²), L{cos ωt} = s/(s²+ω²); derivative L{f'(t)} = sF(s) − f(0).

  • Fourier series for period 2π: f(x) = a₀/2 + Σ(a_n cos nx + b_n sin nx); coefficients a_n = (1/π)∫f(x)cos nx dx, b_n = (1/π)∫f(x)sin nx dx over one period.

  • Matrix: determinant of 2×2 [[a,b],[c,d]] is ad − bc; inverse exists if determinant ≠ 0; eigenvalues solve det(A − λI) = 0.

  • Probability: P(A∪B) = P(A) + P(B) − P(A∩B); Bayes' theorem P(A|B) = P(B|A)P(A)/P(B).

  • Calculus: d/dx(x^n) = n x^(n−1); ∫x^n dx = x^(n+1)/(n+1) + C (n ≠ −1); product rule (uv)' = u'v + uv'.

  • Numerical methods: Newton–Raphson iteration x_{n+1} = x_n − f(x_n)/f'(x_n); trapezoidal rule ∫_a^b f(x)dx ≈ (h/2)[f(a) + 2Σf(x_i) + f(b)].

  • Complex numbers: Euler's formula e^(jθ) = cos θ + j sin θ; magnitude of a + jb is √(a² + b²); argument is tan⁻¹(b/a).

  • Differential equations: first-order linear dy/dx + P(x)y = Q(x) has integrating factor e^(∫P dx).

Quick reference

Engineering Management, Ethics and Professional Practice

  • Project management: critical path is the longest duration path through the network; total float = LS − ES = LF − EF; critical activities have zero float.

  • CPM/PERT: PERT uses three time estimates (optimistic, most likely, pessimistic); expected time t_e = (a + 4m + b)/6; variance = ((b − a)/6)².

  • Break-even analysis: break-even quantity Q = F/(P − V), where F = fixed cost, P = unit price, V = variable cost per unit.

  • Depreciation: straight-line D = (C − S)/n; declining balance uses a fixed percentage of book value each year.

  • Engineering ethics: paramount obligation is public safety, health, and welfare; engineers must disclose conflicts of interest and avoid deceptive practices.

  • Professional codes (e.g., IEEE, ASCE) require competence only in one's field, confidentiality of proprietary information, and giving credit for others' work.

  • Contract types: lump-sum (fixed price) shifts cost risk to contractor; cost-plus shifts risk to owner; unit-price is used for uncertain quantities.

  • Quality management: PDCA cycle (Plan–Do–Check–Act); ISO 9001 specifies quality management system requirements.