Stack effect
Buoyancy-driven airflow caused by indoor-outdoor temperature differences; warm air rises and exits high while cold air enters low, producing pressure differences that increase with building height.
Thermal boundary
The continuous insulation layer separating conditioned from unconditioned space; gaps or breaks in this boundary create thermal bridging and localized heat loss.
Air barrier
The continuous material that resists airflow across the building enclosure; it must be sealed at penetrations and transitions to control infiltration and exfiltration.
Vapor retarder placement
Vapor retarders belong on the warm side of the assembly; cold-climate assemblies place them inside, while hot-humid assemblies avoid interior retarders to allow inward drying.
U-value
The rate of heat transfer through an assembly per unit area and temperature difference; it equals the reciprocal of R-value and includes framing and other thermal bridges.
Sensible heat formula
Air heat content change equals 1.08 times airflow in CFM times the dry-bulb temperature difference; used to calculate heating or cooling delivered by an air stream.
Dew point
The temperature at which air reaches saturation and moisture condenses; locating it within an assembly identifies surfaces at risk of hidden condensation and decay.
Blower door CFM50
Airflow measured at 50 Pa depressurization; it quantifies envelope leakage and, divided by conditioned floor area, gives a normalized airtightness benchmark.
Effective leakage area
An estimate of the total equivalent hole size in the envelope, derived from blower door data and referenced to 4 Pa; useful for comparing homes of different size.
Duct leakage to outside
Leakage from the duct system to unconditioned space, measured by combining duct blaster and blower door tests; it wastes conditioned air and degrades pressure balance.
Zone pressure diagnostic
A test using multiple pressure taps and a calibrated fan to map which building cavities connect to conditioned space and where leakage paths cross the pressure boundary.
Combustion appliance zone
The space containing combustion equipment; testing measures worst-case depressurization with exhaust fans running to confirm appliances vent safely without spillage.
Spillage
Combustion gases escaping from an appliance draft hood into the room rather than up the flue; detected by flame or smoke observation and CO monitoring.
Infrared thermography
Thermal imaging that reveals surface temperature differences; interpretation requires adequate indoor-outdoor temperature difference and confirmation of suspected air leaks or missing insulation.
Static pressure
The resistance to airflow in a duct system, measured across the air handler; excessive static pressure reduces delivered airflow and indicates restrictive filters, coils, or ducts.
Moisture content
The percentage of water by weight in a material such as wood; readings above about 20 percent indicate conditions favorable for mold growth and decay.
Degree-day method
An energy estimating technique using heating or cooling degree days multiplied by building conductance; it approximates annual space-conditioning energy from weather data.
UA calculation
The sum of each envelope area multiplied by its U-value; total UA times the indoor-outdoor temperature difference gives steady-state heat loss in Btu per hour.
Base load
The portion of utility consumption not driven by outdoor temperature, such as water heating, appliances, and lighting; separating it improves weather-normalized savings estimates.
Simple payback
Installed measure cost divided by estimated annual energy savings; it ignores fuel escalation and measure life, so it is paired with life-cycle analysis.
Savings to investment ratio
The present value of lifetime savings divided by installed cost; values above one indicate the measure returns more than its cost over the analysis period.
Marginal savings
The incremental savings from each additional measure; it declines as improvements accumulate, so measure order affects total predicted savings.
Weather normalization
Adjusting consumption data for heating or cooling degree days so that different years or homes can be compared on a common basis.
Measure prioritization
Ranking improvements by health and safety first, then durability and moisture, then envelope, HVAC, and controls; economics inform but do not override safety.
Work scope
A written document specifying each measure, quantity, material, and sequence, with test-in and test-out requirements and clear separation of safety items.
ASHRAE 62.2
A residential ventilation standard specifying whole-building and local exhaust rates based on floor area and bedroom count; referenced after air sealing tightens a home.
Worst-case depressurization
The maximum negative pressure in a combustion appliance zone with all exhaust fans operating and interior doors closed; it determines combustion safety risk.
Informed consent
Documented client agreement to recommended measures after being told of costs, benefits, and any health or safety tradeoffs of the proposed work.
Test-in and test-out
Pre-work and post-work diagnostic measurements such as blower door and combustion tests that document baseline conditions and verify achieved performance.
Change order
A written modification to the agreed scope when field conditions differ from the audit, documenting added or removed measures and revised pricing before work proceeds.
Quality assurance inspection
Post-installation verification that measures meet specification, including visual checks and diagnostic retesting, with results compared to the original audit baseline.