BPI HHE study materials
BPI HHE study resources

BPI HHE cheat sheet

BPI HHE · Keep the key ideas within reach.

Quick reference

Healthy Home Evaluation

  • A healthy home evaluation is a systematic walkthrough that documents moisture, ventilation, combustion safety, contaminants, pests, and safety hazards room by room before any remediation is recommended.

  • Standard evaluation sequence: exterior and drainage, roof and attic, basement or crawlspace, mechanical systems, kitchen and baths, living spaces, then occupant interview and records review.

  • Moisture indicators to record: water staining, efflorescence, bubbling paint, musty odor, rusted fasteners, warped or cupped flooring, and visible mold growth on organic surfaces.

  • Relative humidity target range for occupied homes is generally 30-50 percent; sustained levels above 60 percent support dust mite and mold amplification.

  • A moisture meter reading above roughly 16-20 percent wood moisture content indicates elevated moisture; new construction framing is typically targeted below 19 percent.

  • Combustion safety screening includes backdraft testing of atmospherically vented appliances, spillage checks at the draft hood, and confirmation of a carbon monoxide alarm on each level.

  • Evaluation documentation should pair each finding with a location, photograph, measurement, and severity rating so that recommendations are traceable and verifiable.

  • Occupant interview topics: water leaks history, heating fuel type, recent renovations, pesticide use, pets, smoking, and health symptoms with their timing and location patterns.

Quick reference

Building Science Fundamentals

  • The four control layers of a building enclosure are water, air, vapor, and thermal; water control has priority because bulk water causes the most damage fastest.

  • Stack effect: warm indoor air rises and exits high in the building, drawing outdoor air in low; driving pressure increases with height and indoor-outdoor temperature difference.

  • Air leakage moves far more moisture through assemblies than vapor diffusion; a small hole can transport more water vapor than a large area of permeable material.

  • The dew point is the temperature at which air reaches saturation; condensation forms on any surface at or below the dew point of adjacent air.

  • Vapor retarder placement follows climate: in cold climates it goes on the warm-in-winter interior side; in hot-humid climates a vapor retarder on the exterior is generally avoided.

  • Insulation must be installed in full contact with an air barrier and without gaps; a gap of about 5 percent of an insulated area can reduce effective R-value by roughly half.

  • Pressure boundaries separate conditioned from unconditioned space; the thermal boundary, air boundary, and pressure boundary should be continuous and aligned.

  • R-value measures conductive resistance; U-factor is its reciprocal (U = 1/R), and assembly U-factors are summed rather than averaged by area-weighted parallel path methods.

Quick reference

Indoor Environmental Quality

  • ASHRAE Standard 62.2 sets residential ventilation rates: about 7.5 cfm per occupant plus 0.01 cfm per square foot of conditioned floor area, with a minimum floor value.

  • Radon is the second leading cause of lung cancer in the United States; the EPA action level is 4 picocuries per liter, and mitigation is recommended at or above that level.

  • Carbon monoxide alarms should be installed outside sleeping areas and on each level; the EPA 8-hour average ambient limit is 9 ppm and the 1-hour limit is 35 ppm.

  • PM2.5 refers to particles 2.5 micrometers or smaller, which penetrate deep into the lungs; filtration is rated by MERV, with MERV 13 capturing most fine particles.

  • Formaldehyde is a common off-gassing VOC from pressed wood products, some foams, and combustion; it is a known human carcinogen and irritant.

  • Dust mites thrive at relative humidity above 50-60 percent and feed on shed skin; reducing indoor humidity is the primary control measure.

  • A blower door test measures envelope leakage in cubic feet per minute at 50 pascals; tighter homes require mechanical ventilation to protect indoor air quality.

  • Environmental tobacco smoke is a mixture of gases and particles; there is no safe level of exposure, and separation by distance or ventilation does not eliminate exposure.

Quick reference

Occupant Health and Safety

  • Carbon monoxide binds hemoglobin with roughly 200-250 times the affinity of oxygen, forming carboxyhemoglobin and impairing oxygen delivery to tissues.

  • Classic CO poisoning symptoms are nonspecific: headache, dizziness, nausea, fatigue, and confusion; symptom relief when leaving the building is a key diagnostic clue.

  • Fall hazards are addressed with grab bars in baths, stair handrails on both sides, adequate lighting, and removal of trip hazards such as loose rugs and cords.

  • Scald prevention: set water heater delivery to about 120 degrees Fahrenheit; at 140 degrees a serious scald can occur in seconds.

  • Lead paint hazards are highest in homes built before 1978; deteriorated paint, friction surfaces, and renovation dust are primary exposure pathways for children.

  • Asthma triggers in homes include mold, pests and their debris, secondhand smoke, nitrogen dioxide from unvented gas cooking, and fine particulate matter.

  • Combustion appliances require adequate makeup air; a tightly sealed home with exhaust fans can depressurize and backdraft naturally drafted water heaters and furnaces.

  • Emergency preparedness for occupants includes working smoke and CO alarms, a posted escape plan, and knowledge of utility shutoff locations.