- Healthy Home Evaluation
- A structured room-by-room assessment documenting moisture, ventilation, combustion safety, contaminants, pests, and injury hazards, paired with measurements and occupant history to guide prioritized recommendations.
- Relative Humidity Target
- The generally recommended indoor range of 30 to 50 percent; sustained levels above 60 percent support mold growth and dust mite populations.
- Moisture Meter Use
- A pin or pinless instrument that estimates moisture content in wood and building materials; readings above roughly 16 to 20 percent indicate elevated moisture needing investigation.
- Efflorescence
- A white powdery salt deposit on masonry surfaces that signals water migrating through the material and evaporating, often indicating an active moisture pathway.
- Backdraft Testing
- A combustion safety check that confirms flue gases spill into the home rather than venting outdoors, performed on atmospherically vented appliances under worst-case fan operation.
- Occupant Interview
- A structured conversation covering leak history, fuel types, renovations, pesticide use, pets, smoking, and symptom timing that helps correlate health complaints with building conditions.
- Four Control Layers
- The building enclosure systems for water, air, vapor, and thermal control; water control ranks first because bulk water causes the fastest and most severe damage.
- Stack Effect
- Buoyancy-driven air movement in which warm indoor air rises and escapes high while outdoor air enters low; the driving pressure grows with building height and temperature difference.
- Dew Point
- The temperature at which air becomes saturated with water vapor; condensation forms on any surface at or below the dew point of the adjacent air.
- Vapor Retarder Placement
- Installation rule based on climate: place the retarder on the warm-in-winter interior side in cold climates; avoid exterior vapor barriers in hot-humid climates.
- Air Leakage Versus Diffusion
- Air leakage transports far more moisture through assemblies than vapor diffusion; a small opening can move more water vapor than a large permeable surface.
- Pressure Boundary
- The continuous plane separating conditioned from unconditioned space; it should align with the thermal and air boundaries to prevent moisture and energy problems.
- R-Value and U-Factor
- R-value is resistance to conductive heat flow and U-factor is its reciprocal (U equals 1 divided by R); lower U-factor means better insulating performance.
- Thermal Bridging
- Heat flow through framing and other conductive elements that bypass insulation; it reduces effective assembly R-value and can create cold surfaces where condensation forms.
- ASHRAE 62.2
- The residential ventilation standard specifying mechanical ventilation rates, roughly 7.5 cfm per occupant plus 0.01 cfm per square foot of conditioned area, with a minimum floor.
- Radon Action Level
- The EPA threshold of 4 picocuries per liter in indoor air; at or above this level, mitigation is recommended because radon is a leading cause of lung cancer.
- Carbon Monoxide Limits
- EPA ambient reference values of 9 ppm averaged over 8 hours and 35 ppm over 1 hour, used to judge whether combustion appliance emissions are adequately controlled.
- PM2.5
- Airborne particles 2.5 micrometers or smaller that penetrate deep into the lungs and bloodstream; filtration is rated by MERV, with MERV 13 capturing most fine particles.
- Formaldehyde
- A volatile organic compound emitted by pressed wood products, some foams, and combustion; it is a known human carcinogen and a respiratory and eye irritant.
- Dust Mite Control
- Dust mites thrive when indoor relative humidity exceeds 50 to 60 percent; lowering humidity is the primary and most effective control measure.
- Blower Door Test
- A diagnostic that depressurizes a home to 50 pascals and measures leakage in cubic feet per minute, quantifying envelope tightness and the need for mechanical ventilation.
- Environmental Tobacco Smoke
- A mixture of gases and fine particles from burning tobacco; no safe exposure level exists, and distance or general ventilation does not eliminate occupant exposure.
- Carboxyhemoglobin
- The compound formed when carbon monoxide binds hemoglobin with roughly 200 to 250 times the affinity of oxygen, impairing oxygen delivery to tissues and organs.
- CO Poisoning Symptoms
- Nonspecific complaints including headache, dizziness, nausea, fatigue, and confusion; improvement when occupants leave the building is a key diagnostic clue.
- Scald Prevention
- Setting water heater delivery near 120 degrees Fahrenheit; at 140 degrees a serious scald can occur within seconds of exposure.
- Lead Paint Hazard
- Deteriorated lead paint, friction surfaces, and renovation dust in pre-1978 housing are primary exposure pathways, especially harmful to young children's development.
- Fall Hazard Controls
- Grab bars in bathrooms, continuous handrails on both sides of stairs, adequate lighting, and removal of loose rugs and cords reduce the most common home injury mechanism.
- Asthma Triggers at Home
- Common triggers include mold, pest debris, secondhand smoke, nitrogen dioxide from unvented gas cooking, and fine particulate matter; source control is the primary strategy.
- Makeup Air
- Outdoor air supplied to replace air exhausted by fans and combustion appliances; insufficient makeup air depressurizes the home and can backdraft naturally drafted equipment.
- Depressurization Risk
- Negative indoor pressure from exhaust fans or duct leakage in tight homes can pull soil gas and flue products indoors, raising radon and carbon monoxide exposure.
- Smoke and CO Alarms
- Interconnected alarms placed outside sleeping areas and on each level provide early warning; combined with a posted escape plan they form the core home emergency readiness measure.
- Nitrogen Dioxide Source
- A combustion byproduct emitted by unvented gas ranges and poorly vented appliances; it irritates airways and is associated with asthma symptoms in children.