Ampacity

The maximum continuous current, in amperes, that a conductor can carry under stated installation conditions without exceeding its rated temperature limit and thereby damaging insulation.

Related: Conductor Ampacity Correction, Ambient Temperature Rating
Conductor Ampacity Correction

A calculation that adjusts a conductor's base ampacity for actual conditions such as higher ambient temperature or more bundled current-carrying conductors, so the protected current stays within safe limits.

Related: Ampacity, Ambient Temperature Rating, Derating
Ambient Temperature Rating

The temperature of the surrounding air or soil used when selecting conductor and equipment ratings; exceeding the assumed value reduces allowable current and may require a higher temperature-rated insulation.

Related: Ampacity, Conductor Ampacity Correction
Derating

Reducing a component's permitted current or rating to reflect adverse conditions such as heat, grouping of conductors, or continuous loading, ensuring the installation remains within safe operating limits.

Related: Conductor Ampacity Correction, Duty Cycle
Voltage Drop

The loss of voltage along a circuit caused by conductor resistance and reactance; excessive drop at the load can cause poor equipment performance and overheating, so limits are applied to feeder and branch circuits.

Related: Ampacity, Feeder
Overcurrent

Any current exceeding the rated current of equipment or the ampacity of a conductor, which can result from overload, short circuit, or ground fault and must be interrupted before damage occurs.

Related: Overcurrent Protective Device, Short Circuit, Ground Fault
Overcurrent Protective Device

A fuse or circuit breaker that automatically opens a circuit when current exceeds a set value, protecting conductors and equipment from overloads, short circuits, and fault currents.

Related: Overcurrent, Short Circuit, Interrupting Rating
Interrupting Rating

The maximum fault current a protective device can safely interrupt at its rated voltage; the device must have a rating at least equal to the available fault current at its point of installation.

Related: Available Fault Current, Overcurrent Protective Device
Available Fault Current

The maximum current that could flow at a given point in a system during a short circuit or ground fault, determined by source impedance and circuit conductors, and used to select adequately rated equipment.

Related: Interrupting Rating, Short Circuit, Ground Fault
Short Circuit

An unintended low-impedance connection between two energized conductors of different potential, producing very high current that must be cleared rapidly to prevent fire and equipment damage.

Related: Overcurrent, Available Fault Current, Ground Fault
Ground Fault

An unintended electrical connection between an energized conductor and ground or grounded metal, which can cause shock hazard and must be detected and cleared by protective devices.

Related: Bonding, Grounding Electrode, Short Circuit
Bonding

The permanent joining of metallic parts to form an electrically conductive path that ensures electrical continuity and the capacity to safely conduct any fault current likely to be imposed.

Related: Ground Fault, Grounding Electrode, Equipment Grounding Conductor
Grounding Electrode

A conductive object, such as a rod, plate, or metal water pipe, that is in direct contact with the earth and connects the grounding system to ground.

Related: Bonding, Ground Fault
Equipment Grounding Conductor

The conductor that connects the non-current-carrying metal parts of equipment to the grounding system, providing a low-impedance path for fault current back to the source.

Related: Bonding, Ground Fault, Overcurrent Protective Device
Feeder

A circuit conductor, or set of conductors, that carries power from the service equipment or source to a final branch-circuit overcurrent device or distribution point.

Related: Branch Circuit, Voltage Drop
Branch Circuit

The circuit conductors between the final overcurrent protective device and the outlets or equipment it supplies, forming the last stage of power distribution to loads.

Related: Feeder, Overcurrent Protective Device
Continuous Load

A load expected to operate at maximum current for three hours or more, requiring conductors and overcurrent devices to be sized with additional capacity to manage heat buildup.

Related: Duty Cycle, Derating
Duty Cycle

The pattern of operating periods and rest periods of equipment, expressed as a proportion of time under load, which affects heating and the required equipment rating.

Related: Continuous Load, Derating
Disconnecting Means

A device or group of devices that safely disconnects all ungrounded conductors of a circuit or equipment from its source of supply, allowing isolation for maintenance and emergency control.

Related: Lockout/Tagout, Overcurrent Protective Device
Lockout/Tagout

A documented safety procedure in which energy sources are isolated, locked, and tagged so equipment cannot be re-energized while workers service or repair it.

Related: Disconnecting Means, Working Near Live Parts
Working Near Live Parts

Performing tasks close enough to exposed energized conductors that a shock or arc hazard exists, requiring limits of approach, qualified persons, and appropriate protective equipment.

Related: Arc Flash, Lockout/Tagout, Personal Protective Equipment
Arc Flash

A sudden, high-energy electrical discharge through air between conductors or from a conductor to ground, producing intense heat, light, pressure, and molten metal that can injure workers.

Related: Arc Flash Boundary, Personal Protective Equipment, Working Near Live Parts
Arc Flash Boundary

The calculated distance from energized equipment within which a person could receive a second-degree burn from an arc flash, marking the limit for required protective clothing.

Related: Arc Flash, Personal Protective Equipment
Personal Protective Equipment

Clothing and gear such as insulated gloves, flame-resistant garments, face shields, and safety glasses worn to reduce injury from shock, arc flash, and thermal hazards.

Related: Arc Flash, Arc Flash Boundary, Working Near Live Parts
Permit to Work

A formal written authorization that confirms hazards are identified, controls are in place, and a specific task may proceed safely within defined conditions and time limits.

Related: Lockout/Tagout, Field Safety Representative
Field Safety Representative

A person certified to inspect and declare electrical work compliant with the applicable code and regulation, and authorized to issue or withhold approval for connection and energization.

Related: Electrical Inspection, Permit to Work, Declaration of Compliance
Electrical Inspection

A systematic examination of an electrical installation against code requirements, covering conductors, protection, grounding, equipment, and documentation, before the work is approved for use.

Related: Field Safety Representative, Declaration of Compliance, Deficiency Notice
Declaration of Compliance

A signed statement by the responsible certified person confirming that completed electrical work meets the applicable code and regulation and is safe to energize.

Related: Field Safety Representative, Electrical Inspection
Deficiency Notice

A written record issued when an inspection finds work that does not meet code requirements, listing the non-compliant items that must be corrected and re-inspected before approval.

Related: Electrical Inspection, Field Safety Representative
Electrical Permit

An official authorization required before installing or altering electrical equipment, enabling inspection and ensuring the work is performed and verified by qualified persons.

Related: Electrical Inspection, Declaration of Compliance
Qualified Person

A worker who has demonstrated the skills and knowledge of electrical principles, code requirements, and hazards needed to safely perform assigned work without supervision.

Related: Field Safety Representative, Working Near Live Parts
Insulation Resistance Test

A measurement using an insulation tester to verify that insulation between conductors and ground has sufficiently high resistance, detecting moisture, contamination, or damage before energization.

Related: Electrical Inspection, Continuity Test
Continuity Test

A check confirming that a conductive path exists and has low resistance, commonly used to verify bonding, grounding connections, and correct circuit routing before equipment is energized.

Related: Bonding, Insulation Resistance Test
Class B-R Certificate of Qualification

A certification class authorizing the holder to act as a field safety representative for electrical work within a defined scope, as set out in the applicable electrical regulation.

Related: Field Safety Representative, Scope of Certification
Scope of Certification

The defined limits of electrical work, voltage, or equipment types that a certified field safety representative is permitted to inspect and approve under their class of qualification.

Related: Class B-R Certificate of Qualification, Field Safety Representative
Code Compliance

The condition of an installation meeting all applicable requirements of the adopted electrical code and regulation, including installation methods, protection, grounding, and marking.

Related: Electrical Inspection, Deficiency Notice
Single-Line Diagram

A drawing using single lines and symbols to show the electrical distribution arrangement, including sources, protective devices, feeders, and loads, used for planning and inspection.

Related: Feeder, Available Fault Current