BC Gas Fitter ARD study materials
BC Gas Fitter ARD study resources

BC Gas Fitter ARD key terms

BC Gas Fitter ARD · Get comfortable with the vocabulary.

Combustion Air

The air supplied to a burner that mixes with fuel gas and supports burning. It must be provided from indoors, outdoors, or both in quantities set by code for safe, complete combustion.

Related: Excess Air, Dilution Air, Flue Gas
Excess Air

Air supplied beyond the theoretical amount needed for complete combustion. It ensures all fuel burns but lowers flame temperature and carries heat up the flue, so it is limited by tuning.

Related: Combustion Air, Flue Gas
Dilution Air

Air that enters a draft hood or draft diverter and mixes with flue products. It cools the exhaust and stabilizes draft, so it is not the same as air used for combustion.

Related: Draft Hood, Combustion Air
Flue Gas

The hot products of combustion leaving an appliance, including carbon dioxide, water vapour, nitrogen, and trace carbon monoxide. It must be vented safely outdoors to prevent poisoning and corrosion.

Related: Combustion Air, Vent Connector
Draft Hood

A device on a draft-hood-equipped appliance that admits dilution air and breaks the effect of chimney draft on the combustion process. It also spills flue products if the vent is blocked.

Related: Dilution Air, Spillage, Vent Connector
Spillage

The escape of flue products from the relief opening of a draft hood into the room rather than up the vent. It signals poor draft, blockage, or an undersized vent and is a carbon monoxide hazard.

Related: Draft Hood, Carbon Monoxide
Carbon Monoxide

A colourless, odourless, toxic gas produced by incomplete combustion. It binds with haemoglobin and can be fatal at low concentrations, so appliances must be adjusted and vented to keep it minimal.

Related: Spillage, Excess Air
Manifold Pressure

The gas pressure measured at the appliance manifold, downstream of the regulator, while the appliance operates. It is set by the manufacturer and checked with a manometer during commissioning and service.

Related: Gas Pressure Regulator, Manometer
Gas Pressure Regulator

A device that reduces higher supply pressure to a steady lower pressure delivered to the appliance burner. It compensates for changes in supply pressure and load to keep combustion stable.

Related: Manifold Pressure, Lock-Up Pressure
Lock-Up Pressure

The outlet pressure a regulator holds when flow stops and the downstream valve closes. It must not rise enough to over-fire or damage controls when the appliance cycles off.

Related: Gas Pressure Regulator, Manifold Pressure
Manometer

An instrument that measures low gas or air pressure, commonly a U-tube or digital gauge reading in inches of water column. It is used to set manifold pressure and verify draft.

Related: Manifold Pressure, Draft Gauge
Water Column

A unit of low pressure equal to the height of a water column it supports, abbreviated in. w.c. Natural gas manifold pressures are typically a few inches of water column and are measured with a manometer.

Related: Manometer, Manifold Pressure
Vent Connector

The pipe or duct that carries flue products from an appliance to the chimney or vent system. It must slope upward, be supported, and be sized and joined so flue gas cannot leak indoors.

Related: Flue Gas, Draft Hood
Sediment Trap

A short drip leg installed at the bottom of a gas piping drop near the appliance. It catches dirt, scale, and moisture so they do not reach the gas valve and burner orifices.

Related: Gas Valve, Orifice
Orifice

A precisely sized hole, usually a removable brass spud, that meters gas into a burner. Its size is matched to the fuel type and manifold pressure to produce the correct heat input.

Related: Manifold Pressure, Heat Input
Heat Input

The rate of energy delivered to an appliance by burning fuel, usually stated in Btu per hour. It is calculated from gas flow and heating value and compared to the rating plate.

Related: Orifice, Clock Method
Clock Method

A field test that times gas meter dial movement to measure actual gas flow, then converts it to input in Btu per hour. It confirms whether an appliance is firing at its rated input.

Related: Heat Input, Orifice
Gas Valve

A control that opens and closes the gas supply to the burner in response to the thermostat or safety circuit. It must close tightly and is often combined with a pressure regulator and safety shutoff.

Related: Thermocouple, Sediment Trap
Thermocouple

A safety device made of two dissimilar metals that generates a small voltage when heated by a pilot flame. That voltage holds the gas valve open, and loss of flame closes the valve.

Related: Gas Valve, Flame Sensor
Flame Sensor

A probe, often a flame rectification rod, that detects the presence of a burner flame and proves it to the control module. If no flame is sensed, the gas valve is shut off.

Related: Thermocouple, Gas Valve
Bonding

The permanent joining of metallic parts to form an electrically continuous path that ensures electrical continuity and safe conduction. It is required on gas piping to prevent a shock or arc hazard.

Related: Grounding, Equipment Grounding Conductor
Grounding

A deliberate connection between an electrical circuit or equipment and the earth or a grounded reference point. It limits voltage during faults and stabilizes system voltage for safety.

Related: Bonding, Equipment Grounding Conductor
Equipment Grounding Conductor

The conductor that connects the non-current-carrying metal parts of equipment to the grounding system. It provides a low-impedance fault path so overcurrent devices trip quickly.

Related: Grounding, Bonding
Overcurrent Device

A fuse or circuit breaker that opens a circuit when current exceeds its rating for a set time. It protects conductors and equipment from overheating and fire caused by overloads or short circuits.

Related: Equipment Grounding Conductor, Disconnect Switch
Disconnect Switch

A manually operable device that isolates an appliance or circuit from its power source. It must be located within sight and readily accessible so service work can be done safely.

Related: Overcurrent Device, Line Voltage
Line Voltage

The normal supply voltage of a circuit, such as 120 or 240 volts, as opposed to low control voltage. Line-voltage work requires de-energizing and verifying before touching conductors.

Related: Low Voltage, Disconnect Switch
Low Voltage

A reduced control voltage, often 24 volts, used for thermostats and control circuits. It operates relays and gas valves and is safer to work on, but is still a shock and short-circuit source.

Related: Line Voltage, Transformer
Transformer

A device that changes alternating voltage by magnetic induction, commonly stepping 120 volts down to 24 volts for controls. It must be matched to load and protected against short circuits.

Related: Low Voltage, Line Voltage
Backflow Preventer

A device that stops reverse flow of water or other fluid into a potable water system. It protects drinking water from contamination by boiler water, chemicals, or cross-connections.

Related: Cross-Connection, Vacuum Breaker
Cross-Connection

Any actual or potential link between a potable water supply and a source of contamination. It must be eliminated or controlled with backflow protection to keep drinking water safe.

Related: Backflow Preventer, Vacuum Breaker
Vacuum Breaker

A backflow device that opens to atmosphere when supply pressure drops, breaking a siphon. It is used on hose bibs and some appliance connections but cannot be used under continuous pressure.

Related: Backflow Preventer, Cross-Connection
Air Gap

A physical separation between a water outlet and the flood level of a fixture or receptacle. It is the most reliable backflow protection because no mechanical parts can fail.

Related: Backflow Preventer, Cross-Connection
Water Hammer

A pressure surge caused by a sudden stop of water flow in a pipe, producing a banging noise and stress on joints. It is controlled with arrestors, slow-closing valves, or proper pipe support.

Related: Expansion Tank, Pressure Relief Valve
Expansion Tank

A closed tank with a captive air charge that absorbs the volume increase of heated water in a closed system. It prevents excessive pressure and protects piping, valves, and the water heater.

Related: Pressure Relief Valve, Water Hammer
Pressure Relief Valve

A safety valve that opens automatically when pressure reaches a set limit, discharging fluid to a safe location. It protects tanks and piping from overpressure and must never be plugged or capped.

Related: Expansion Tank, Low Water Cutoff
Low Water Cutoff

A safety control on a boiler that shuts off the burner when the water level falls below a safe point. It prevents overheating and dry firing that could crack the boiler or cause an explosion.

Related: Pressure Relief Valve, Steam Trap
Steam Trap

A device that discharges condensate and non-condensable gases from a steam line or heating unit while holding back live steam. A failed trap wastes energy or causes water hammer and poor heating.

Related: Water Hammer, Condensate Return
Condensate Return

The system that collects condensed steam and returns it to the boiler feedwater supply. Efficient return saves energy and water, and its condition affects boiler operation and chemical treatment.

Related: Steam Trap, Low Water Cutoff