BOABC Level 2 flashcards
BOABC Level 2 · Build recall with a focused review session.
32 cards. Read the term and the definition here. The deck at the top of this page is optional.
- Dead load
- The vertical load produced by the weight of permanent construction, including structure, finishes, partitions, and fixed equipment. It is treated as a constant service load in design calculations.
- Live load
- The occupancy-dependent load from people, furniture, and movable equipment. It is specified by use group in the building code and is not reduced below code minimums regardless of actual occupancy.
- Load combination
- A factored or unfactored set of loads applied simultaneously to check a structure. Allowable stress design uses service combinations; strength design multiplies each load by a load factor.
- Allowable bearing pressure
- The maximum soil pressure a foundation may impose without excessive settlement or shear failure. Footing area equals total service load, including footing weight, divided by this pressure.
- Deflection limit
- A maximum permissible sag expressed as a fraction of span, such as L/360. The ratio is selected according to whether the member supports brittle finishes, general floors, or nonceiling roofs.
- Means of egress
- A continuous, unobstructed path from any point in a building to a public way. It comprises the exit access, the exit, and the exit discharge, and each portion has its own width and rating rules.
- Travel distance
- The measured length along the egress path from the most remote point in a space to the nearest exit. Codes cap it by occupancy, and it is measured along the natural walking path.
- Fire-resistance rating
- The time in hours an assembly resists fire under a standardized test. It applies to the complete assembly, including supports and penetrations, not to an individual material alone.
- Thermal bridging
- Heat flow that bypasses insulation through framing, shelf angles, or other conductive members. It lowers the effective R-value of the whole assembly below the cavity insulation value.
- U-factor
- The overall rate of heat transmission through an assembly per unit area and temperature difference. It is the reciprocal of assembly R-value and is area-weighted across components.
- Vapor retarder
- A material that limits water vapor diffusion through an assembly. Its placement depends on climate, and it is installed on the warm side of the insulation in cold climates.
- Air barrier continuity
- An unbroken plane that resists uncontrolled air leakage through the envelope. It must be sealed at joints, penetrations, and transitions between wall, roof, and foundation assemblies.
- Footing
- The widened base of a foundation that spreads the column or wall load over sufficient soil area. Its width is set by allowable bearing pressure and total service load.
- Slab-on-grade
- A concrete slab placed directly on prepared soil and used as a floor. It typically includes a vapor retarder and granular base beneath it and may carry thickened edges at load-bearing walls.
- Occupant load
- The computed number of people a space is designed to hold. It equals floor area divided by an occupant-load factor and drives egress width, exits, and fixture counts.
- Drainage fixture unit
- A relative measure of the waste-flow load a fixture imposes on a drainage system. Pipe sizing tables relate accumulated fixture units to allowable drain diameter and slope.
- Water supply fixture unit
- A relative measure of the demand a fixture places on the water distribution system. It accounts for flow rate, duration, and frequency of use when sizing supply piping.
- Trap seal
- The water retained in a fixture trap that blocks sewer gas. Common codes require a depth between 2 and 4 inches, maintained by venting and by limiting evaporation.
- Fixture vent
- A pipe that admits air to a drainage system near a trap and lets sewer gas escape outdoors. Each trap must be vented, and the arm length is limited by pipe size.
- Stack vent
- The extension of a soil or waste stack above the highest fixture branch to the open air. It relieves pressure in the stack and protects trap seals on the fixtures served.
- Building drain
- The lowest horizontal piping of a drainage system that receives waste from soil and waste stacks. It conveys flow to the building sewer, which begins outside the building wall.
- Building sewer
- The pipe that carries sewage from the building drain to the public sewer or private disposal system. It begins at the point where the drain exits the building.
- Drainage slope
- The fall per unit length required for gravity flow in a drain. Common code values are 1/4 inch per foot for 2-inch pipe and 1/8 inch per foot for 3-inch and larger pipe.
- Residual pressure
- The water pressure remaining at a fixture while it is flowing. Codes require a minimum, often about 8 psi, so fixtures operate correctly without excessive supply pipe sizing.
- Pressure-reducing valve
- A device that lowers incoming water pressure to a safe downstream value. It is typically required when static pressure exceeds about 80 psi to protect fixtures and piping.
- Water hammer
- A pressure surge caused by a sudden stop in flow at a quick-closing valve. Arrestors with trapped air or mechanical chambers absorb the shock near the source.
- Backflow prevention
- Protection against reverse flow that could contaminate the potable supply. Air gaps provide the highest protection; reduced-pressure-zone assemblies serve high-hazard connections.
- Air gap
- An unobstructed vertical separation between a supply outlet and the flood-level rim of a fixture. It is the most reliable backflow protection because no mechanical part can fail.
- Water heater relief valve
- A temperature-and-pressure relief device that discharges near the floor or to a safe location. It prevents tank rupture from overheating or excessive pressure and must not be capped.
- Expansion tank
- A vessel that absorbs the volume increase of heated water in a closed system. It prevents excess pressure from damaging piping and fixtures and is installed on the cold supply side.
- Cleanout
- An accessible fitting that allows a drain to be rodded or inspected. Codes require them at the base of stacks, at changes in direction, and at intervals along long horizontal runs.
- Flood-level rim
- The edge of a fixture over which water would overflow onto the floor. It sets the required height of the air gap and the location of backflow prevention devices.