BOABC Level 2 key terms
BOABC Level 2 · Get comfortable with the vocabulary.
- Live Load
- Related: Dead Load, Occupancy Classification
The weight of people, furniture, stored goods, and other movable items a floor or roof must support. Building codes set minimum values for different occupancies.
- Dead Load
- Related: Live Load, Span
The permanent, stationary weight of a structure itself, including walls, floors, roofs, and fixed equipment. It stays constant throughout the building's life.
- Occupancy Classification
- Related: Live Load, Means of Egress
The category assigned to a building based on how it is used, such as residential, mercantile, or assembly. The category determines which code requirements apply.
- Means of Egress
- Related: Exit Access, Exit Width
The continuous, unobstructed path people use to leave a building during an emergency, including exit access, the exit itself, and exit discharge to a public way.
- Exit Access
- Related: Means of Egress, Exit Width
The portion of the escape route that leads from any point in a building to an exit. It includes aisles, corridors, and intervening rooms.
- Exit Width
- Related: Occupant Load, Means of Egress
The clear, usable dimension of a corridor, stair, or doorway that allows occupants to pass during evacuation. Codes set minimum widths based on occupant load.
- Occupant Load
- Related: Exit Width, Fixture Count
The total number of people a space is calculated to hold, based on floor area and use. It drives requirements for exits, stairs, and plumbing fixtures.
- Fire-Resistance Rating
- Related: Fire Separation, Type of Construction
The time in hours a building assembly can withstand fire exposure while maintaining its structural function. Ratings are shown in hours, such as one or two.
- Fire Separation
- Related: Fire-Resistance Rating, Type of Construction
A wall, floor, or assembly that resists the spread of fire between areas of a building. Its required rating depends on occupancy and construction type.
- Type of Construction
- Related: Fire-Resistance Rating, Fire Separation
A classification, usually numbered I through V, describing how fire-resistant a building's structural elements are. Higher types permit less combustible material.
- Span
- Related: Dead Load, Live Load
The clear horizontal distance a beam, joist, or other structural member must bridge between supports. Span controls the required member size and depth.
- Header
- Related: Span, Load-Bearing Wall
A horizontal structural member placed over an opening such as a door or window to carry the loads above it and transfer them to adjacent framing.
- Load-Bearing Wall
- Related: Header, Span
A wall that supports weight from floors, roofs, or other walls above it. It cannot be removed or altered without providing alternate structural support.
- Footing
- Related: Frost Depth, Foundation Drain
The widened base of a foundation that spreads building loads over a larger soil area. Footing size and depth depend on soil conditions and frost depth.
- Frost Depth
- Related: Footing, Foundation Drain
The depth to which soil freezes in winter at a given location. Footings must extend below this depth to prevent frost heave from lifting the structure.
- Foundation Drain
- Related: Footing, Frost Depth
A perforated pipe or drainage system placed around or beneath a foundation to remove groundwater. It protects the basement or crawl space from water intrusion.
- Stud
- Related: Load-Bearing Wall, Header
A vertical framing member in a wall, typically spaced at regular intervals, that supports wall finishes and transfers loads to horizontal framing.
- Rafter
- Related: Span, Roof Pitch
A sloping structural member that supports roof sheathing and spans from the ridge or a ridge beam down to the wall top plate.
- Roof Pitch
- Related: Rafter, Flashing
The slope of a roof expressed as a ratio of vertical rise to horizontal run. Pitch affects drainage, material choice, and snow shedding.
- Flashing
- Related: Roof Pitch, Weep Hole
Sheet metal or other material installed to shed water at joints and penetrations, such as roof valleys, chimneys, and wall intersections. It prevents leakage.
- Weep Hole
- Related: Flashing, Foundation Drain
A small opening left in a wall, veneer, or masonry assembly that lets trapped moisture drain out. It helps prevent water damage behind cladding.
- Egress Window
- Related: Means of Egress, Window Sill
A window in a sleeping room that is large enough and low enough to allow escape in an emergency. Codes specify minimum opening size and sill height.
- Window Sill
- Related: Egress Window
The horizontal bottom member of a window frame. Its height above the floor matters for egress requirements and fall protection.
- Guardrail
- Related: Stairway Rise, Handrail
A barrier installed along open edges of floors, balconies, stairs, and landings to prevent falls. Codes set minimum heights and limit opening sizes.
- Stairway Rise
- Related: Guardrail, Handrail
The vertical height of a single stair step, measured from one tread surface to the next. Consistent rise is required for safe stair use.
- Handrail
- Related: Stairway Rise, Guardrail
A graspable rail along a stairway or ramp that gives users support and stability. Codes specify its height, continuity, and clearance from the wall.
- Fixture Count
- Related: Occupant Load, Water Closet
The number of plumbing fixtures such as toilets, sinks, and lavatories required for a building. It is calculated from occupant load and use.
- Water Closet
- Related: Fixture Count, Trap
A toilet fixture that receives human waste and discharges it into the drainage system through a trap. Codes set its water use and clearance requirements.
- Trap
- Related: Water Closet, Vent
A U-shaped fitting that holds a water seal to block sewer gases from entering a building. Every fixture connection generally requires one.
- Vent
- Related: Trap, Drain-Waste-Vent System
A pipe that allows air to enter the drainage system and lets sewer gases escape above the roof. It protects trap seals from siphonage.
- Drain-Waste-Vent System
- Related: Vent, Trap
The network of pipes that carries sewage and gray water away while admitting air to keep pressures balanced. It includes drains, waste lines, and vents.
- Cleanout
- Related: Drain-Waste-Vent System, Trap
An accessible fitting with a removable cap that lets maintenance workers clear blockages in a drain line. Codes specify where cleanouts must be installed.
- Backflow Preventer
- Related: Cross-Connection, Water Supply Line
A device that stops contaminated water from flowing backward into a potable water supply. It protects drinking water from cross-connections.
- Cross-Connection
- Related: Backflow Preventer, Water Supply Line
Any actual or potential link between a potable water system and a source of contamination. Cross-connections must be eliminated or protected against.
- Water Supply Line
- Related: Backflow Preventer, Water Heater
A pipe that carries potable water under pressure from the main to fixtures and appliances. Sizing must maintain adequate pressure at the farthest outlet.
- Water Heater
- Related: Water Supply Line, Temperature and Pressure Relief Valve
An appliance that heats and stores potable water for domestic use. Installation rules cover temperature relief, venting, and seismic strapping.
- Temperature and Pressure Relief Valve
- Related: Water Heater
A safety device on a water heater that opens to release excess pressure or temperature. It must discharge to a safe location through a proper pipe.
- Slope
- Related: Drain-Waste-Vent System, Cleanout
The downward fall of a horizontal drain pipe, expressed as a ratio or percent, that lets wastewater flow by gravity. Too little slope causes clogs.
- Trap Arm
- Related: Trap, Slope
The section of pipe between a fixture trap and the main drain line. Its length and slope are limited so the trap seal is not lost.