  • Beam attenuation follows I = I0·e^(−μx), where μ is the linear attenuation coefficient and x is path length; the half-value layer equals 0.693/μ.

  • Photoelectric absorption dominates at low photon energy and scales roughly with Z³/E³, which is why high-Z contrast agents (iodine Z=53, barium Z=56) improve soft-tissue contrast.

  • Compton scatter dominates at diagnostic energies in soft tissue and is nearly independent of atomic number; it degrades contrast and is the main source of occupational dose.

  • CT numbers follow Hounsfield units: HU = 1000·(μ_tissue − μ_water)/μ_water; water is 0 HU and air is approximately −1000 HU.

  • Inverse-square law: intensity falls with the square of distance, so doubling source-to-detector distance reduces intensity to one quarter.

  • Grid ratio equals grid height divided by interspace width; higher ratio improves scatter cleanup but raises patient dose and requires tighter centering.

  • The photostimulable phosphor plate in computed radiography stores a latent image in electron traps; a scanning laser releases stored energy as blue luminescence proportional to dose.

  • ALARA dose limits for occupational exposure are 20 mSv/year averaged over 5 years (100 mSv per 5 years) with a 50 mSv single-year cap; public exposure is 1 mSv/year.

Quick reference

Magnetic Resonance

  • The Larmor equation states precession frequency f = γB, where γ for hydrogen is 42.58 MHz/T; at 1.5 T the proton frequency is about 63.9 MHz.

  • T1 relaxation is longitudinal recovery (spin-lattice); T2 is transverse decay (spin-spin); T2* adds static field inhomogeneity and is always shorter than T2.

  • TR controls T1 weighting: short TR with short TE gives T1-weighted images; long TR with long TE gives T2-weighted images; long TR with short TE gives proton density.

  • Gadolinium chelates shorten T1 of nearby protons; they are extracellular agents cleared renally, and risk of nephrogenic systemic fibrosis rises with severe renal impairment.

  • The specific absorption rate depends on field strength squared and flip angle squared; it limits how fast high-energy radiofrequency pulses can be applied.

  • Chemical shift in parts per million equals the frequency difference in Hz divided by the Larmor frequency in MHz; fat-water shift grows with field strength.

  • Gradient coils encode spatial position by superimposing linear field gradients; slice selection uses a gradient with a matched radiofrequency bandwidth.

  • The safety zone IV (above 3 T, or a patient with a pacemaker) requires explicit MR-conditional device labeling before scanning; ferromagnetic projectiles remain the leading hazard.

Quick reference

Nuclear Medicine

  • Technetium-99m has a 6.02-hour half-life, 140 keV gamma emission, and is eluted from a molybdenum-99 generator; parent Mo-99 has a 66-hour half-life.

  • Radioactive decay follows A = A0·e^(−0.693t/T½); after n half-lives the remaining activity is A0/2ⁿ.

  • The gamma camera uses a collimator to define direction, a sodium iodide crystal to convert gamma photons to light, and photomultiplier tubes to produce position signals.

  • FDG-PET images glucose metabolism; FDG is trapped after phosphorylation by hexokinase and is not further metabolized, so uptake reflects glycolytic rate.

  • The PET photopeak is 511 keV from positron annihilation; coincidence detection of two back-to-back photons localizes the event along a line of response.

  • Standardized uptake value equals measured activity concentration divided by injected dose per body weight, corrected for decay.

  • Effective half-life combines physical and biological clearance: 1/T_eff = 1/T_phys + 1/T_bio.

  • Iodine-131 emits beta particles (tissue range about 1-2 mm) plus gamma; it is used for thyroid ablation and therapy, while I-123 is preferred for imaging.

Quick reference

Radiation Therapy

  • Absorbed dose is measured in gray (1 Gy = 1 J/kg); the older unit rad equals 0.01 Gy, and 1 Sv equals 100 rem for equivalent dose.

  • The linear-quadratic model gives surviving fraction S = e^(−αD−βD²); the α/β ratio is about 10 Gy for early-responding tumors and about 3 Gy for late tissues.

  • Equivalent dose in 2-Gy fractions uses EQD2 = D·(α/β + d)/(α/β + 2); biologically effective dose uses BED = D·(1 + d/(α/β)).

  • The Bragg peak of protons deposits maximum energy at a defined depth, with near-zero exit dose beyond the peak; spread-out Bragg peaks cover tumor volumes.

  • In external beam therapy, percentage depth dose increases with field size and decreases with depth and with higher beam energy for the buildup region.

  • Tumor control probability and normal tissue complication probability curves are sigmoid; the therapeutic ratio is the separation between them.

  • Brachytherapy dose falls off as the inverse square of distance from the source, so dose rate at distance d is proportional to 1/d².

  • Fractionation exploits the four Rs: repair of sublethal damage, redistribution through the cell cycle, repopulation, and reoxygenation.