CAMRT Radiation Therapy study materials
CAMRT Radiation Therapy study resources

CAMRT Radiation Therapy key terms

CAMRT Radiation Therapy · Get comfortable with the vocabulary.

Gray (Gy)

The SI unit of absorbed radiation dose, equal to one joule of energy deposited per kilogram of material. Treatment prescriptions and dose constraints are stated in gray.

Related: Absorbed dose, Fractionation
Absorbed dose

The amount of radiation energy deposited in a unit mass of tissue, expressed in gray. It predicts biological effect better than exposure or air kerma alone.

Related: Gray (Gy), Equivalent dose
Equivalent dose

A radiation protection quantity that weights absorbed dose by a radiation-type factor reflecting biological harm. It is measured in sievert and used for occupational and public limits.

Related: Sievert (Sv), Absorbed dose
Sievert (Sv)

The SI unit of equivalent and effective dose, representing biological risk rather than raw energy deposition. Annual occupational limits and public limits are expressed in millisievert.

Related: Equivalent dose, ALARA
ALARA

The principle of keeping radiation exposure as low as reasonably achievable, accounting for economic and social factors. It guides shielding, workload planning, and daily practice decisions.

Related: Sievert (Sv), Shielding calculation
Fractionation

Dividing a prescribed radiation dose into multiple smaller treatments delivered over days or weeks. It exploits repair differences between tumor and normal tissue to widen the therapeutic window.

Related: Gray (Gy), Therapeutic ratio
Therapeutic ratio

The balance between tumor control probability and normal tissue complication probability. A favorable ratio means high tumor kill with acceptable toxicity, and it is the central aim of treatment planning.

Related: Fractionation, Normal tissue tolerance
Normal tissue tolerance

The dose a healthy organ or structure can receive before clinically significant injury becomes likely. Planning constraints are derived from published tolerance data for each organ.

Related: Therapeutic ratio, Dose-volume histogram
Dose-volume histogram

A graphical summary showing what volume of a structure receives at least a given dose. It is used to evaluate target coverage and organ-at-risk sparing in a treatment plan.

Related: Normal tissue tolerance, Isodose line
Isodose line

A contour on a planning image connecting points that receive the same radiation dose. It visually demonstrates dose distribution and coverage relative to targets and organs at risk.

Related: Dose-volume histogram, Treatment planning system
Treatment planning system

Software that models beam geometry, dose deposition, and patient anatomy to produce a deliverable plan. It calculates dose distributions using algorithms such as superposition or Monte Carlo.

Related: Isodose line, Dose calculation algorithm
Dose calculation algorithm

The mathematical method a planning system uses to predict dose in tissue, ranging from simple correction-based models to convolution-superposition and Monte Carlo methods. Accuracy matters most in heterogeneous tissue.

Related: Treatment planning system, Heterogeneity correction
Heterogeneity correction

An adjustment in dose calculation that accounts for differences in density, such as lung or bone, compared with water. Ignoring it can cause clinically meaningful dose errors.

Related: Dose calculation algorithm, Computed tomography
Linear accelerator

A device that accelerates electrons to high energy and directs them at a target to produce megavoltage photon beams, or directly delivers electron beams. It is the main treatment machine in modern radiotherapy.

Related: Multileaf collimator, Beam energy
Multileaf collimator

A set of computer-controlled tungsten leaves in the accelerator head that shapes the beam aperture. It enables conformal fields, dynamic arc therapy, and intensity modulation.

Related: Linear accelerator, Intensity-modulated radiation therapy
Intensity-modulated radiation therapy

A technique in which the beam fluence is varied across the field by moving collimator leaves, creating highly conformal dose distributions. It improves sparing of concave or adjacent organs at risk.

Related: Multileaf collimator, Volumetric modulated arc therapy
Volumetric modulated arc therapy

An arc-based delivery technique in which gantry rotation, dose rate, and multileaf collimator motion are modulated continuously. It produces highly conformal plans with short delivery times.

Related: Intensity-modulated radiation therapy, Multileaf collimator
Image-guided radiation therapy

The use of imaging immediately before or during treatment to verify and correct patient position and target location. It reduces geometric uncertainty and allows smaller margins.

Related: Set-up margin, Cone-beam computed tomography
Cone-beam computed tomography

A volumetric imaging method using a flat-panel detector and a divergent beam mounted on the treatment unit. It provides three-dimensional verification of patient position in the treatment room.

Related: Image-guided radiation therapy, Computed tomography
Set-up margin

The extra distance added around a clinical target volume to account for positioning error, organ motion, and beam uncertainty. It converts a clinical target volume into a planning target volume.

Related: Planning target volume, Image-guided radiation therapy
Planning target volume

A geometric volume that adds a margin around the clinical target volume to ensure the prescribed dose actually reaches the target despite daily uncertainties. It is a planning concept, not a biological one.

Related: Set-up margin, Gross tumor volume
Gross tumor volume

The visible or palpable extent of tumor demonstrated by imaging or clinical examination. It is the starting point of the volume chain used in conformal treatment planning.

Related: Clinical target volume, Planning target volume
Clinical target volume

The gross tumor volume plus a margin for microscopic subclinical disease that should receive a curative dose. It represents tissue that must be treated, independent of set-up uncertainty.

Related: Gross tumor volume, Planning target volume
Brachytherapy

Radiotherapy delivered by placing a sealed radioactive source inside or very close to the tumor. Its steep dose fall-off spares distant tissue, and dose rate depends on source activity.

Related: Afterloading, Inverse square law
Afterloading

A technique in which applicators are positioned in the patient first and the radioactive source is loaded afterward by remote control. It reduces staff dose compared with manual placement.

Related: Brachytherapy, ALARA
Inverse square law

The rule that radiation intensity from a point source falls in proportion to the square of the distance. Doubling distance reduces intensity to one quarter, which underpins shielding and source handling.

Related: Brachytherapy, Shielding calculation
Shielding calculation

The process of determining barrier thickness needed to reduce dose outside a treatment or imaging room to acceptable levels. It uses workload, use factor, occupancy, and attenuation data.

Related: Inverse square law, ALARA
Beam energy

The accelerating potential or nominal energy of a treatment beam, commonly stated in megavolts for photons. Higher energy penetrates more deeply but shifts the dose maximum deeper and increases neutron production.

Related: Linear accelerator, Percentage depth dose
Percentage depth dose

The ratio of dose at a given depth in tissue to the dose at the depth of maximum dose, expressed as a percentage. It describes how a beam attenuates and builds up with depth.

Related: Beam energy, Build-up region
Build-up region

The shallow tissue layer where dose rises to a maximum because secondary electrons are being generated faster than they are absorbed. Skin sparing occurs because the maximum lies below the surface.

Related: Percentage depth dose, Bolus
Bolus

A tissue-equivalent material placed on the skin to build up dose at or near the surface. It is used when the target lies close to the skin or the surface is irregular.

Related: Build-up region, Percentage depth dose
Computed tomography

An imaging method that reconstructs cross-sectional images from X-ray projections and reports tissue density in Hounsfield units. Planning systems use these data for anatomy and density correction.

Related: Hounsfield unit, Heterogeneity correction
Hounsfield unit

A scaled number expressing tissue attenuation relative to water, with water set to zero and air near minus one thousand. It allows density information to be mapped for dose calculation.

Related: Computed tomography, Heterogeneity correction
Magnetic resonance imaging

An imaging method that uses a strong magnetic field, radiofrequency pulses, and relaxation behavior of hydrogen nuclei to produce soft-tissue contrast without ionizing radiation. It is valuable for tumor and organ delineation.

Related: T1 relaxation, T2 relaxation
T1 relaxation

The recovery of longitudinal magnetization after a radiofrequency pulse, characterized by a time constant T1. Tissues with short T1 recover quickly and appear bright on T1-weighted images.

Related: T2 relaxation, Magnetic resonance imaging
T2 relaxation

The decay of transverse magnetization from spin-spin interactions, characterized by a time constant T2. Tissues with long T2 lose signal slowly and appear bright on T2-weighted images.

Related: T1 relaxation, Magnetic resonance imaging
Radiopharmaceutical

A radioactive compound administered for diagnosis or therapy, combining a radionuclide with a carrier that targets specific tissue. Its distribution and decay determine imaging signal or therapeutic dose.

Related: Half-life, Gamma camera
Half-life

The time required for half of the radioactive atoms in a sample to decay. It determines how long a radiopharmaceutical remains active and influences imaging timing and waste handling.

Related: Radiopharmaceutical, Radionuclide generator
Radionuclide generator

A system in which a longer-lived parent nuclide decays into a shorter-lived daughter that is eluted for use. It provides on-site access to short-lived tracers such as technetium-99m.

Related: Half-life, Radiopharmaceutical
Gamma camera

An imaging device that detects gamma rays from an administered radionuclide using a collimator, scintillation crystal, and photomultiplier tubes. It produces planar images reflecting tracer distribution.

Related: Radiopharmaceutical, Positron emission tomography
Positron emission tomography

An imaging technique that detects pairs of annihilation photons produced when positrons interact with electrons. Coincidence detection localizes the tracer and supports quantitative metabolic imaging.

Related: Gamma camera, Radiopharmaceutical