CA CEG key terms
CA CEG · Get comfortable with the vocabulary.
- Energy management program
- Related: Energy baseline, Energy intensity, Measurement and verification
A structured, ongoing effort to reduce energy use and cost through planning, tracking, and improvement. It typically includes goal setting, baseline development, action plans, measurement, and management review.
- Energy baseline
- Related: Measurement and verification, Energy intensity, Regression model
A reference level of energy use, adjusted for relevant variables such as weather or production, against which savings are measured. It represents what consumption would have been without the efficiency actions.
- Energy intensity
- Related: Energy baseline, Energy use index
Energy consumed per unit of output or activity, such as kWh per unit produced or kBtu per square foot. It allows comparison across time or facilities with different scales.
- Energy use index (EUI)
- Related: Energy intensity, Benchmarking
Annual energy consumption per unit of floor area, often expressed in kBtu per square foot per year. It is used to benchmark a building's energy performance against similar buildings.
- Benchmarking
- Related: Energy use index (EUI), Energy baseline
Comparing a facility's energy performance with that of similar facilities or with historical data. It helps identify poor performers and prioritize improvement opportunities.
- Energy audit
- Related: Level I audit, Level II audit, Level III audit
A systematic study of energy flows in a facility to identify how energy is used and where efficiency can be improved. Audits range from walk-through assessments to detailed engineering analyses.
- Level I audit
- Related: Energy audit, Level II audit
A preliminary walk-through assessment that identifies obvious waste and low-cost opportunities. It relies on utility bills and visual inspection rather than detailed measurements.
- Level II audit
- Related: Energy audit, Level III audit
A detailed energy survey that includes measurement of major end uses and engineering calculations of savings for identified measures. It provides cost and savings estimates sufficient for project prioritization.
- Level III audit
- Related: Level II audit, Measurement and verification
A comprehensive engineering analysis that uses detailed data collection, modeling, and sometimes monitoring to support major capital decisions. It provides refined savings and cost estimates for specific projects.
- Measurement and verification (M&V)
- Related: Energy baseline, Regression model, Option C
The process of using measurements and calculations to reliably determine actual savings from an energy project. It compares post-installation energy use with an adjusted baseline.
- Regression model
- Related: Energy baseline, Measurement and verification
A statistical technique that relates energy use to driving variables such as outdoor temperature or production level. It is used to adjust baselines and estimate savings in M&V.
- Option C (whole facility)
- Related: Measurement and verification, Option B (retrofit isolation)
An M&V approach that measures energy use for the entire facility using utility meters. It is suitable when savings are large and diverse across the facility.
- Option B (retrofit isolation)
- Related: Measurement and verification, Option C (whole facility)
An M&V approach that measures energy use of the specific system affected by a measure, using dedicated meters or sensors. It isolates savings from other changes in the facility.
- Simple payback period
- Related: Life-cycle cost, Internal rate of return (IRR), Net present value (NPV)
The time required for annual savings to equal the initial project cost, calculated as cost divided by annual savings. It ignores the time value of money and savings after payback.
- Life-cycle cost
- Related: Simple payback period, Net present value (NPV)
The total cost of owning and operating a system over its useful life, including initial cost, energy, maintenance, and replacement. It allows comparison of alternatives with different cost profiles.
- Net present value (NPV)
- Related: Internal rate of return (IRR), Life-cycle cost, Discount rate
The sum of future cash flows discounted to present value, minus the initial investment. A positive NPV indicates a project is expected to add value at the chosen discount rate.
- Internal rate of return (IRR)
- Related: Net present value (NPV), Discount rate
The discount rate at which a project's net present value equals zero. It represents the project's expected annual return and is compared with a hurdle rate.
- Discount rate
- Related: Net present value (NPV), Internal rate of return (IRR)
The rate used to convert future cash flows to present value, reflecting the time value of money and risk. A higher rate reduces the present value of future savings.
- Power factor
- Related: Demand charge, Harmonics, Capacitor bank
The ratio of real power (kW) to apparent power (kVA) in an alternating-current circuit. A low power factor increases current for the same real power and can incur utility penalties.
- Demand charge
- Related: Power factor, Load factor, Demand response
A utility charge based on the maximum rate of energy use (kW or kVA) during a billing period. Reducing peak demand can lower this charge even if total energy use is unchanged.
- Load factor
- Related: Demand charge, Demand response
The ratio of average load to peak load over a period. A high load factor indicates more even energy use and often lower average cost per unit.
- Harmonics
- Related: Power factor, Variable-frequency drive (VFD)
Voltage or current distortions at integer multiples of the fundamental frequency, caused by non-linear loads such as variable-frequency drives. They can overheat equipment and reduce power quality.
- Coefficient of performance (COP)
- Related: Energy efficiency ratio (EER), Variable-frequency drive (VFD)
The ratio of useful heating or cooling output to energy input for a heat pump or refrigeration system. A higher COP indicates greater efficiency at given operating conditions.
- Energy efficiency ratio (EER)
- Related: Coefficient of performance (COP), Variable-frequency drive (VFD)
The ratio of cooling output in Btu per hour to electrical input in watts at a specified condition. It is commonly used to rate unitary air-conditioning equipment.
- Variable-frequency drive (VFD)
- Related: Harmonics, Affinity laws
A device that controls the speed of an electric motor by varying the frequency and voltage of its power supply. It saves energy in fans and pumps by matching output to load.
- Affinity laws
- Related: Variable-frequency drive (VFD)
Relationships showing how flow, head, and power change with speed for fans and pumps. Power varies approximately with the cube of speed, so modest speed reductions yield large energy savings.
- Boiler efficiency
- Related: Economizer, Steam trap, Blowdown
The ratio of useful heat output to fuel energy input, often determined by stack loss and other losses. It can be improved with tune-ups, air-fuel control, and heat recovery.
- Economizer (boiler)
- Related: Boiler efficiency, Blowdown
A heat exchanger that recovers heat from boiler flue gases to preheat feedwater or combustion air. It reduces fuel consumption by lowering stack losses.
- Steam trap
- Related: Boiler efficiency, Blowdown
A valve that automatically discharges condensate and non-condensable gases while preventing steam loss. Failed traps waste steam and degrade system performance.
- Blowdown
- Related: Boiler efficiency, Steam trap
The removal of water from a boiler to control dissolved solids and prevent scale. Excessive blowdown wastes energy, while insufficient blowdown risks boiler damage.
- Thermal envelope
- Related: U-factor, Infiltration, Thermal bridge
The building elements that separate conditioned interior space from the outdoors or unconditioned spaces. Its performance depends on insulation, air sealing, windows, and thermal bridging.
- U-factor
- Related: Thermal envelope, Thermal bridge
The overall rate of heat transfer through an assembly, expressed in Btu per hour per square foot per degree Fahrenheit. Lower U-factors indicate better insulation performance.
- Infiltration
- Related: Thermal envelope, U-factor
Uncontrolled outdoor air entering a building through cracks, gaps, and penetrations. It increases heating and cooling loads and can be reduced by air sealing.
- Thermal bridge
- Related: U-factor, Thermal envelope
A path of relatively high heat conductance through an otherwise insulated assembly, such as a steel stud or concrete slab. It reduces effective insulation and can cause condensation.
- Lighting power density (LPD)
- Related: Luminaire, Ballast, Light-emitting diode (LED)
The installed lighting power per unit of floor area, typically in watts per square foot. It is used in energy codes to limit lighting energy use.
- Ballast
- Related: Lighting power density (LPD), Light-emitting diode (LED)
A device that regulates current and voltage for fluorescent and other discharge lamps. Electronic ballasts operate more efficiently than older magnetic types.
- Light-emitting diode (LED)
- Related: Ballast, Lighting power density (LPD)
A semiconductor light source that converts electricity to light with high efficiency and long life. LEDs are widely used for energy-saving lighting retrofits.
- Combined heat and power (CHP)
- Related: Waste heat recovery, Prime mover
The simultaneous production of electricity and useful thermal energy from a single fuel source. It can achieve much higher overall efficiency than separate generation.
- Waste heat recovery
- Related: Combined heat and power (CHP), Economizer (boiler)
Capturing heat that would otherwise be rejected from a process or equipment and using it for useful purposes such as preheating or space heating. It reduces purchased fuel or electricity.
- Prime mover
- Related: Combined heat and power (CHP)
The engine or turbine that drives an electric generator or mechanical equipment in a CHP or power system. Common types include reciprocating engines, gas turbines, and steam turbines.
- Solar photovoltaic (PV) system
- Related: Inverter, Capacity factor
A system that converts sunlight directly into electricity using semiconductor cells. Its output depends on irradiance, temperature, and orientation.
- Inverter
- Related: Solar photovoltaic (PV) system, Capacity factor
A device that converts direct current (DC) electricity from sources such as solar panels or batteries into alternating current (AC) for use in buildings or the grid.
- Capacity factor
- Related: Solar photovoltaic (PV) system, Inverter
The ratio of actual energy output over a period to the maximum possible output at rated capacity. It indicates how fully a generating source is utilized.
- Greenhouse gas (GHG) emissions
- Related: Carbon footprint, Emissions factor, Renewable energy credit (REC)
Gases such as carbon dioxide, methane, and nitrous oxide that trap heat in the atmosphere. Energy projects reduce emissions by lowering fossil fuel combustion.
- Carbon footprint
- Related: Greenhouse gas (GHG) emissions, Emissions factor
The total greenhouse gas emissions caused directly or indirectly by an entity, expressed as carbon dioxide equivalent. It is used to track and report climate impact.
- Emissions factor
- Related: Greenhouse gas (GHG) emissions, Carbon footprint
The amount of a pollutant or greenhouse gas released per unit of energy consumed or produced. It is used to convert energy savings into emissions reductions.
- Renewable energy credit (REC)
- Related: Greenhouse gas (GHG) emissions, Solar photovoltaic (PV) system
A tradable certificate representing the environmental attributes of one megawatt-hour of renewable electricity. It allows buyers to claim renewable energy use.