OBC Building Structural flashcards
OBC Building Structural · Build recall with a focused review session.
36 cards. Read the term and the definition here. The deck at the top of this page is optional.
- Strength design inequality
- Factored resistance must equal or exceed factored load effect: phi times nominal strength is greater than or equal to the sum of load factors times nominal loads.
- Load combination 1.2D+1.6L
- Basic ASCE 7 strength combination for gravity; used when live load governs and no lateral load acts. Dead load is amplified by 1.2, live by 1.6.
- Importance factor
- Multiplier on wind, seismic, or snow loads based on occupancy category. Typical buildings use 1.0; essential facilities use up to 1.5.
- Deflection limit L/360
- Common serviceability limit for floor members under live load. Span in inches divided by 360 gives allowable deflection; stiffer limits apply to sensitive finishes.
- Stiffness method
- Matrix analysis that assembles member stiffness into a global matrix, solves for joint displacements, then back-calculates member forces. Basis for most structural software.
- Moment distribution method
- Iterative hand method using fixed-end moments, joint stiffness ratios, and half carry-over to far ends. Continues until unbalanced moments become negligible.
- Influence line
- Diagram of a response quantity at a fixed point as a unit load moves across the structure. Used to position moving loads for maximum effect.
- Second-order P-Delta effect
- Additional moments caused by gravity loads acting on laterally displaced shape. Must be included when stability coefficient exceeds 0.10 per ASCE 7.
- Live load reduction
- Permits reducing uniform live load based on influence area using L equals L0 times (0.25 plus 15 divided by square root of KLL times AT). Not allowed above 100 psf.
- Flat roof snow load
- Computed as 0.7 times exposure, thermal, and importance factors times ground snow load. Minimum value of 20 times importance factor applies when ground snow exceeds 20 psf.
- Snow drift surcharge
- Additional trapezoidal load on lower roofs or beside parapets caused by wind-deposited snow. Drift height depends on upper roof length and ground snow load.
- Concentrated live load check
- Uniform floor live loads must also be checked against a concentrated load applied over a small area, such as 2000 pounds on 2.5 square feet for offices.
- Velocity pressure
- Wind pressure computed as 0.00256 times exposure, topographic, and directionality factors times basic wind speed squared. Increases with height above grade.
- Seismic base shear
- Total lateral design force equal to seismic response coefficient times effective seismic weight. Coefficient depends on spectral acceleration, response modification, and importance.
- Response modification factor R
- Reflects ductility and overstrength of a lateral system; higher R means more energy dissipation and lower design forces. Special moment frames use R of 8.
- Site class amplification
- Soft soils amplify seismic shaking, especially at long periods. Site coefficients Fa and Fv increase design spectral accelerations for classes D through F.
- Terzaghi bearing capacity
- Ultimate bearing pressure equals cohesion term plus surcharge term plus weight term, each multiplied by bearing capacity factors Nc, Nq, and N-gamma.
- Consolidation settlement
- Time-dependent compression of saturated clay under added load. Computed from compression index, initial void ratio, layer thickness, and change in effective stress.
- At-rest earth pressure
- Lateral pressure coefficient for soil that does not yield, equal to one minus sine of friction angle. Higher than active pressure and used for restrained walls.
- Liquefaction susceptibility
- Loose saturated sands below the water table can lose strength during earthquakes. Evaluated using standard penetration resistance and cyclic stress ratio.
- Tension-controlled section
- Concrete section where tensile strain in steel exceeds the yield strain plus 0.003 at nominal strength. Permits phi of 0.90 for flexure.
- Minimum flexural reinforcement
- Concrete beams require steel area at least the greater of 3 times square root of f-prime-c divided by fy, or 200 divided by fy, times width times effective depth.
- Concrete development length
- Embedment needed to develop bar yield force without pullout. Depends on bar diameter, concrete strength, cover, spacing, and coating or epoxy factors.
- Concrete shear strength Vc
- Nominal shear carried by concrete, approximately 2 times square root of f-prime-c times web width times effective depth in psi units for nonprestressed members.
- Masonry modulus of elasticity
- Em equals 900 times the specified masonry compressive strength per TMS 402. Used to compute stiffness and slenderness effects in masonry walls.
- Mortar Type S
- Medium-high strength mortar with 1800 psi compressive strength, commonly specified for structural masonry walls. Balances strength, workability, and bond.
- Masonry slenderness ratio
- Ratio of effective height to radius of gyration, h over r. Allowable compressive stress is reduced as this ratio increases beyond 99.
- Load duration factor
- NDS factor CD adjusts reference design values for duration of maximum load: 1.0 normal, 1.15 snow, 1.6 wind and seismic, 0.9 permanent only.
- Beam stability factor
- NDS factor CL reduces allowable bending stress for laterally unbraced beams. Depends on slenderness ratio, effective length, and depth-to-width ratio.
- Wood column stability
- Factor Cp reduces allowable compressive stress based on effective length to depth ratio. Computed from Euler buckling stress and reference compressive strength.
- Steel lateral-torsional buckling
- Unbraced beams may fail by twisting and lateral deflection before reaching plastic moment. Nominal strength depends on unbraced length relative to Lp and Lr.
- Block shear rupture
- Connection failure combining tensile rupture on one plane with shear rupture on a perpendicular plane. Nominal strength uses net and gross areas with a reduction factor.
- Fillet weld strength
- Nominal strength equals 0.6 times electrode strength times effective throat (0.707 times weld size) times length. Resistance factor is 0.75 for LRFD.
- Wood char rate
- Approximate rate of 1.5 inches per hour at which heavy timber burns. Used to size members for required fire resistance ratings.
- Intumescent coating
- Fire-protective paint that swells when heated to insulate steel. Thickness depends on section factor and required hourly rating.
- Prying action
- Additional bolt tension caused by flexure of connected plates at a tee or angle connection. Must be included in bolt tension design.