- Accessory occupancy limit
- An occupancy is accessory when it is subordinate to the main use and typically occupies less than 10 percent of the floor area; larger areas require a full mixed-occupancy analysis.
- High-rise threshold
- A building is generally classified as a high-rise when its occupied floor exceeds 75 feet above the lowest fire-department vehicle access level, triggering additional fire-protection systems.
- Occupant load factor
- A code-specified area per person used to compute occupant load for a given use; dividing floor area by the factor yields the number of occupants used for egress and fixtures.
- Separated occupancies
- A mixed-occupancy design approach in which fire barriers with specified ratings separate different occupancy groups, allowing each to be evaluated under its own height and area limits.
- Change of occupancy
- A change in a building's use that can trigger code upgrades to structural, egress, and fire-protection systems, with the extent based on comparing the hazard of old and new uses.
- Incidental use areas
- Small rooms such as mechanical, storage, or boiler rooms that are regulated by a separate table of incidental-use requirements rather than treated as full occupancies.
- Automatic sprinkler requirement
- Sprinklers are generally mandated in high-rise buildings, large assembly occupancies, and buildings exceeding allowable height or area limits, providing both life safety and allowable increases.
- Standpipe classes
- Class I provides 2.5-inch connections for fire-department use; Class II provides 1.5-inch connections for occupant use; Class III combines both in a single system.
- Stairwell pressurization
- A smoke control strategy that maintains positive pressure in exit stairs during a fire to keep them tenable and free of smoke for occupant evacuation.
- Fire damper location
- A listed device installed where ducts penetrate fire-resistance-rated assemblies to maintain the assembly's integrity, unless an approved code exception applies to the configuration.
- Visible alarm notification
- Strobes or other visible signals required in public and common areas and in accessible spaces to alert occupants who are deaf or hard of hearing during a fire emergency.
- Exit illumination duration
- Emergency lighting along egress paths must provide the required illumination for a minimum duration, commonly 90 minutes, so occupants can exit during a power loss.
- Seismic Design Category
- A classification (A through F) based on seismic hazard and building risk that determines required seismic-force-resisting systems and detailing; higher categories demand ductile systems.
- Construction type limits
- Construction Types I through V set allowable building height and area based on fire resistance; Type I-A permits the greatest limits and Type V-B the least.
- Structural fireproofing
- Protection applied to structural members (spray fireproofing, intumescent coatings, encasement) so their fire resistance matches the required construction type rating.
- Continuous air barrier
- A sealed envelope layer that limits uncontrolled air leakage through walls, roofs, and joints; continuity at transitions and penetrations is essential to performance.
- Thermal bridging
- A path of high heat conductance through the envelope, such as a structural penetration, that reduces effective insulation and must be addressed in complex geometry.
- Snow drift load
- An additional roof load caused by snow accumulation against parapets or higher roof sections; it is often governing on complex or stepped roofs.
- Means of egress parts
- The three components of egress: exit access (path to the exit), the exit itself, and exit discharge (path from exit to public way).
- Exit remoteness rule
- Two required exits must be separated by at least one-half the diagonal of the area served, ensuring that a single fire event does not block both escape routes.
- Egress width calculation
- Required egress width equals occupant load multiplied by a capacity factor (e.g., 0.2 in/person on level floors, 0.15 in/person on stairs), subject to minimum widths.
- Travel distance limit
- The maximum permitted distance from the most remote point to an exit, varying by occupancy and sprinkler status, commonly 150 to 400 feet depending on conditions.
- Accessible means of egress
- A continuous accessible path out of a building, including compliant doors, ramps, and in high-rise buildings an area of refuge or accessible elevator.
- Door swing direction
- Egress doors must swing in the direction of travel when serving large occupant loads, so occupants can exit without the door blocking the path.
- Plumbing fixture ratios
- Code tables that set the number of water closets, lavatories, and drinking fountains based on occupant load and use, with accessible fixtures required for each type.
- Outdoor air ventilation
- Mechanical systems must supply outdoor air at rates based on occupants and use, with higher rates for spaces such as assembly areas and lower rates for storage.
- Life-safety power branch
- An emergency power branch dedicated to loads such as egress lighting, fire alarm, and fire pumps, separated from optional standby loads and tested regularly.
- Elevator standby power
- In high-rise buildings, at least one elevator must be connected to standby power so it remains usable for firefighter operations and accessible egress during outages.
- Plenum coordination
- Ducts, sprinklers, and lighting sharing a ceiling plenum must maintain clearances so sprinkler spray patterns and exit signage are not obstructed.
- Permit before construction
- A permit must be obtained before construction, alteration, or change of use; work without one can trigger stop-work orders and additional inspections.
- Special inspections
- Inspections mandated by code for items such as structural welding, high-strength bolting, and post-installed anchors, performed by approved agencies and documented.
- Certificate of occupancy
- A document issued after final inspections confirm the building complies with approved plans and applicable codes and is safe for its intended use.