OBC House Exam study materials
OBC House Exam study resources

OBC House Exam cheat sheet

OBC House Exam · Keep the key ideas within reach.

Quick reference

Building Codes and Regulatory Compliance

  • Model codes (IBC, IRC, IEBC, IMC, IPC, NEC/NFPA 70) become enforceable only when adopted by the local jurisdiction, often with amendments.

  • Occupancy classification drives allowable height, area, egress, and fire protection; mixed uses require either separated occupancies or a calculated allowable-area method.

  • Type of construction (I-A through V-B) sets permitted building height, number of stories, and fire-resistance ratings for structural elements.

  • Building area limits are set by Table 506.2; frontage increase is allowed for yards abutting public ways or open space.

  • A change of occupancy triggers compliance review under the International Existing Building Code, including egress and fire-resistance checks.

  • Permits are required before construction, alteration, or demolition; work without a permit is a code violation subject to stop-work orders.

  • The code official has authority to interpret code provisions and may require tests or engineering analysis to demonstrate compliance.

  • Variance and appeal requests generally go to a board of appeals, not to the inspector who issued the denial.

Quick reference

Structural Systems and Foundations

  • Dead load is the self-weight of structure and fixed finishes; live load is occupancy and use load per ASCE 7 Chapter 4.

  • Load combinations per ASCE 7 use 1.2D + 1.6L for basic strength design and include wind, seismic, and snow terms.

  • Soil bearing capacity must be verified by geotechnical report; presumptive values in code are minimums when no test data exist.

  • Footings must extend below the frost line or be designed for frost heave; depth varies by region and soil type.

  • Continuous footings require reinforcement sized for bending and must bear on undisturbed or compacted soil.

  • Lateral load resistance comes from shear walls, braced frames, or moment frames; collectors and diaphragms must be continuous to the foundation.

  • Wood framing: notches in the tension edge of a joist are limited, and holes must be located away from the top and bottom edges.

  • Concrete strength is verified by cylinder tests at 28 days; low breaks may require core testing or structural evaluation.

Quick reference

Building Envelope and Weatherproofing

  • The building envelope must control bulk water, capillary action, air movement, vapor diffusion, and thermal transfer.

  • Water-resistive barriers must be shingled so upper courses lap over lower courses, and penetrations must be flashed.

  • Flashing is required at roof-wall intersections, valleys, chimneys, window heads, sills, and thresholds exposed to weather.

  • A continuous air barrier reduces uncontrolled infiltration and must be sealed at joints, penetrations, and transitions.

  • Vapor retarder placement depends on climate: on the warm side in cold climates, and generally omitted or vapor-permeable in hot-humid walls.

  • Roof slope determines roofing type; low-slope roofs below 3:12 use membrane systems, while steep-slope roofs use shingles or tiles.

  • Weep holes and a drainage plane behind masonry veneer allow moisture to escape and prevent trapped water damage.

  • Condensation risk is evaluated by comparing dew point location with the assembly's thermal and vapor profile.

Quick reference

Mechanical, Electrical, and Plumbing Systems

  • HVAC sizing follows Manual J for load calculation, Manual S for equipment selection, and Manual D for duct design.

  • Duct leakage in unconditioned space wastes energy; ducts should be sealed and insulated to the required R-value.

  • Combustion appliances need adequate combustion air; direct-vent appliances draw air from outdoors.

  • Electrical service size depends on calculated demand load; the NEC provides demand factors for dwellings and commercial occupancies.

  • GFCI protection is required in bathrooms, kitchens, garages, outdoors, and near sinks; AFCI protection is required on dwelling branch circuits.

  • Bonding and grounding must connect metallic piping and equipment to the grounding electrode system to clear faults.

  • Plumbing fixtures require traps, venting, and proper slope on horizontal drains; DWV systems must maintain trap seals.

  • Water heater temperature and pressure relief valves must discharge to a safe location and never be capped.

Quick reference

Fire and Life Safety

  • Means of egress has three parts: exit access, exit, and exit discharge; each must be continuous and unobstructed.

  • Egress width is based on occupant load multiplied by a capacity factor, typically 0.2 inches per occupant for level components.

  • Two exits are generally required when occupant load exceeds the threshold for the occupancy, or where travel distance is excessive.

  • Exit signs and emergency lighting are required along the means of egress, and illumination must be maintained during power loss.

  • Fire-resistance-rated assemblies use listed materials and must be inspected; penetrations require listed firestop systems.

  • Sprinkler systems are governed by NFPA 13; residential systems by NFPA 13R, and they may allow area and height increases.

  • Smoke alarms and carbon monoxide alarms are required in dwellings and must be interconnected where required by code.

  • Fire extinguishers must be selected by hazard class (A, B, C, D, K) and mounted with proper travel distance to the hazard.

Quick reference

Energy Efficiency and Sustainability

  • The energy code (IECC or ASHRAE 90.1) sets minimum envelope, lighting, and mechanical efficiency requirements.

  • Prescriptive path uses tables of R-values, U-factors, and fenestration limits; performance path uses whole-building energy modeling.

  • Building envelope air leakage is verified by blower door testing in many jurisdictions; targets are expressed in ACH50.

  • Duct leakage testing may be required; leakage is measured in CFM25 per 100 square feet of conditioned floor area.

  • Lighting power density limits are set in watts per square foot by space type; controls such as occupancy sensors are required.

  • HVAC equipment efficiency is rated by SEER, HSPF, or AFUE for residential systems and by COP or kW/ton for commercial.

  • Renewable energy and solar-ready provisions may be triggered by code adoption, project size, or jurisdiction.

  • Commissioning verifies that installed systems perform per design intent; it is required for larger commercial projects.

Quick reference

Accessibility and Occupancy Requirements

  • Accessible routes must be at least 36 inches clear width and have a maximum running slope of 1:20 without handrails.

  • Ramps require landings at top and bottom, edge protection, and handrails when the rise exceeds six inches.

  • Accessible parking requires a van-accessible space with an access aisle; signage must be mounted at the required height.

  • Door clear width in an accessible route is 32 inches minimum clear, with maneuvering clearance on both sides.

  • Accessible bathrooms require grab bars, turning space, and a lavatory with knee and toe clearance.

  • Occupant load is calculated by dividing floor area by the occupant load factor for the use and then rounding up.

  • Assembly occupancies have special requirements for aisle width, seating, and egress capacity.

  • Accessible means of egress may require areas of refuge or an accessible route in multi-story buildings.

Quick reference

Construction Materials and Methods

  • Concrete is specified by compressive strength at 28 days, air content for freeze-thaw resistance, and slump for workability.

  • Reinforcement must have specified cover to protect against corrosion; cover varies with exposure conditions.

  • Wood framing members are graded for species and grade; moisture content affects shrinkage and strength.

  • Masonry walls require mortar joint size control and reinforcement or anchors for lateral stability.

  • Steel connections are either bolted or welded; bolt torque and weld inspection are required for structural connections.

  • Roof and floor sheathing must be installed with proper panel orientation, spacing, and fastening per manufacturer instructions.

  • Gypsum board assemblies achieve fire ratings based on layer count, thickness, and fastener spacing.

  • Fasteners must be compatible with treated wood; galvanized or stainless fasteners are required for preserved lumber.

Quick reference

Inspection, Testing, and Plan Review

  • Plan review checks code compliance before permit issuance; deficiencies must be corrected before approval.

  • Required inspections typically include footing, foundation, framing, rough-in, insulation, and final inspections.

  • Concrete placement requires inspection of forms, reinforcement, and embedments before the pour.

  • Framing inspection verifies member size, spacing, connections, and fireblocking before covering.

  • Rough-in inspections for plumbing, mechanical, and electrical occur before concealment by insulation or drywall.

  • Tests include water line pressure tests, drain line water or air tests, and duct leakage testing.

  • Special inspections are required for certain structural work and must be performed by qualified inspectors.

  • Final inspection confirms that all permitted work is complete, tested, and consistent with the approved plans.

Quick reference

Building Codes and Regulatory Compliance

  • Adopted code edition governs the project; later editions do not apply retroactively unless adopted.

  • Certificate of occupancy is issued after final inspection confirms compliance with the approved scope.

  • Fire-resistance ratings are expressed in hours and apply to structural members, shafts, and separations.

  • Occupancy separation requirements depend on the hazard levels of adjacent uses.

  • Accessibility provisions are enforced through the same permit and inspection process as other code requirements.

Quick reference

Structural Systems and Foundations

  • Deflection limits are set by code and material standards; excessive deflection can crack finishes.

  • Expansive soils require special foundation design, often with deepened footings or post-tensioned slabs.

  • Retaining walls must be designed for lateral earth pressure plus surcharge loads.

  • Anchor bolts transfer uplift and shear from the structure to the foundation.

  • Snow drift loads accumulate against parapets and taller adjacent roofs.