32 cards. Read the term and the definition here. The deck at the top of this page is optional.

Occupancy classification
A code category assigned to a building based on its use, which establishes allowable height and area, egress requirements, and required fire protection features.
Type of construction
A classification from Type I through Type V that sets permitted height, stories, and fire-resistance ratings for structural elements based on combustibility and protection.
Certificate of occupancy
A document issued after final inspection confirming that the building complies with the approved plans and may be legally occupied for its stated use.
Change of occupancy
A change in how a building is used, which triggers review of egress, fire protection, and structural adequacy under the existing building code.
Dead load
The permanent weight of the structure itself plus fixed finishes, partitions, and equipment that remain in place throughout the building's life.
Live load
The load produced by occupancy and use, including people, furniture, and movable equipment, determined from code tables by occupancy type.
Frost depth
The depth to which soil freezes in winter; footings must extend below this level or be engineered to resist frost heave.
Soil bearing capacity
The maximum pressure soil can support without excessive settlement, established by geotechnical testing or by presumptive code values when testing is absent.
Shear wall
A wall designed to resist lateral loads from wind or earthquakes by transferring them through the diaphragm to the foundation.
Water-resistive barrier
A membrane behind cladding that sheds bulk water to the exterior and protects sheathing from moisture intrusion, installed with lapped courses.
Flashing
A material installed at joints and penetrations to direct water away from the building, required at roof intersections, valleys, and window openings.
Air barrier
A continuous system of sealed materials that limits uncontrolled air movement through the envelope, reducing energy loss and moisture transport.
Vapor retarder
A material that restricts vapor diffusion through an assembly, placed according to climate to keep condensation from forming within the wall.
Weep hole
A small opening at the base of a masonry veneer or cavity wall that allows trapped moisture to drain to the exterior.
Manual J
A residential load calculation method that determines heating and cooling requirements from envelope, climate, and occupancy inputs before equipment selection.
GFCI protection
A device that interrupts a circuit when it detects a ground fault, required in bathrooms, kitchens, garages, outdoors, and near water sources.
AFCI protection
A device that detects arc faults in branch circuit wiring and de-energizes the circuit, required on dwelling unit branch circuits by the electrical code.
Trap seal
The water in a plumbing trap that blocks sewer gas from entering the building, maintained by proper venting and fixture use.
Temperature relief valve
A safety device on a water heater that opens at excessive temperature or pressure and must discharge to a safe, unobstructed location.
Means of egress
A continuous, unobstructed path from any point in a building to the public way, consisting of exit access, exit, and exit discharge.
Occupant load
The number of people calculated for a space by dividing floor area by the code occupant load factor, used to size egress capacity.
Firestop
A listed material or system installed to seal a penetration through a fire-resistance-rated assembly and maintain its rating.
Travel distance
The measured path length from the most remote point in a space to an exit, limited by code based on occupancy and sprinkler protection.
Blower door test
A diagnostic test that pressurizes a building to measure air leakage, reported in air changes per hour at a specified pressure difference.
Duct leakage test
A measurement of air escaping from ductwork at a specified pressure, reported per unit of conditioned floor area to verify energy code compliance.
Commissioning
A quality process that verifies building systems are installed and perform according to design intent and the owner's requirements.
Lighting power density
The maximum allowed lighting wattage per square foot for a space type, used by energy codes to limit lighting energy use.
Accessible route
A continuous path connecting accessible elements and spaces that meets minimum width, slope, and surface requirements for wheelchair users.
Van-accessible space
A wider parking space with an adjacent access aisle designed for vehicles equipped with wheelchair lifts or ramps.
Area of refuge
A designated space protected from fire where occupants who cannot use stairs may wait for assistance during an emergency evacuation.
Rough-in inspection
An inspection of plumbing, mechanical, and electrical work performed after installation but before concealment by insulation or wall finishes.
Special inspection
An inspection of specific structural or fire-protective work performed by a qualified inspector beyond the standard building department inspections.