OBC HVAC - House flashcards
OBC HVAC - House · Build recall with a focused review session.
33 cards. Read the term and the definition here. The deck at the top of this page is optional.
- Building Code Act, 1992
- Ontario statute that authorizes the Building Code, establishes permit and inspection powers, and defines construction, building, and enforcement responsibilities.
- Ontario Building Code
- Regulation under the Building Code Act containing minimum standards for construction, demolition, change of use, and HVAC installation in Ontario.
- Chief Building Official
- Municipal officer responsible for administering and enforcing the Building Code Act and OBC, including permit issuance, inspections, orders, and stop-work actions.
- Construction under BCA
- Includes erection, alteration, repair, renovation, demolition, and certain installations or changes to a building that trigger permit and Code compliance requirements.
- Building permit requirement
- Before construction or demolition begins, the owner must obtain a permit from the principal authority unless the Act or regulation provides an exemption.
- Referenced standard
- A published technical document adopted by the OBC, such as CSA B149.1 or CSA F280, whose requirements become enforceable as part of the Code.
- Plans and specifications
- Documents submitted with a permit application that must be sufficiently detailed to show compliance with the OBC for the proposed HVAC work.
- Inspector entry power
- A building inspector may enter premises at reasonable times to inspect construction and may require tests or documents to confirm Code compliance.
- Part 6 HVAC scope
- OBC Part 6 sets requirements for heating, ventilating, air-conditioning, duct systems, combustion air, and venting in buildings, with house-specific rules in Part 9.
- Part 9 house HVAC
- OBC Part 9 contains residential requirements for ventilation, heating, air-conditioning, combustion air, and duct installation in houses and small buildings.
- Ventilation requirement
- A house must have a ventilation system that provides outdoor air and exhausts contaminants according to OBC Section 9.32 and referenced standards.
- Heating system capacity
- The installed heating equipment must be sized to maintain the required indoor design temperature at the outdoor winter design condition, based on calculated loads.
- CSA F280 load calculation
- Standard method for calculating residential heating and cooling loads, accounting for envelope, windows, orientation, infiltration, and internal gains before equipment selection.
- Outdoor design temperature
- The winter or summer weather value used in load calculations, taken from the OBC supplementary standards or recognized design data for the location.
- Equipment sizing rule
- Select HVAC equipment whose rated capacity meets the calculated load without excessive oversizing, following OBC, CSA F280, and manufacturer performance data.
- Thermostat location
- A thermostat must be accessible and located to sense representative room temperature, away from direct sunlight, drafts, and heat-producing appliances.
- Combustion air supply
- Fuel-fired appliances need a permanent, unobstructed air supply sized per CSA B149.1 or B139 and OBC, using indoor or outdoor air sources.
- Vent termination clearance
- Vent outlets must be located away from windows, doors, air intakes, and property lines as specified by the appliance listing and CSA venting standards.
- Clearance to combustibles
- The minimum distance between a heat-producing appliance or vent and combustible material, established by the listing, OBC, and manufacturer instructions.
- Carbon monoxide alarm
- A dwelling with a fuel-fired appliance or attached garage must have CO alarms installed in locations required by the OBC to warn occupants of dangerous CO levels.
- Duct insulation requirement
- Ducts in unconditioned spaces must be insulated and sealed to limit heat loss and condensation, with a continuous vapour barrier where required.
- Return air restriction
- Return air must not be drawn from bathrooms, kitchens, garages, or rooms with fuel-fired appliances where contaminants or safety hazards exist.
- Bathroom exhaust fan
- An exhaust fan must remove moisture and odours directly outdoors, with capacity and controls meeting OBC Section 9.32 ventilation requirements.
- Fire damper application
- A fire damper is installed where an air duct penetrates a fire-rated separation to maintain the separation's integrity and must remain accessible for inspection.
- Firestop at penetration
- The annular space between a duct or pipe and a fire-rated assembly must be sealed with an approved firestop system tested to ASTM E814 or equivalent.
- Smoke damper function
- A listed damper installed where smoke control or smoke-tight separation is required, designed to restrict smoke movement through ductwork and remain accessible.
- Energy efficiency compliance
- OBC energy provisions require minimum insulation, equipment efficiency, duct sealing, and airtightness, often demonstrated through Supplementary Standard SB-12 for houses.
- Heat recovery ventilator
- An HRV exhausts stale indoor air and supplies outdoor air while transferring heat between airstreams, improving ventilation and energy performance in tight houses.
- Duct leakage testing
- A test that measures air leakage from duct systems to verify sealing and compliance with energy or commissioning requirements before concealment or occupancy.
- Approved plans on site
- The permit-approved drawings and specifications must be available at the site so the installer and inspector can verify the HVAC work matches the approved design.
- Concealment inspection
- An inspection required before HVAC ducts, vents, or equipment are covered by finishes, allowing the inspector to verify Code compliance while components remain visible.
- As-built documentation
- Final drawings and equipment records reflecting the installed HVAC system, including changes, test results, and maintenance information for the owner.
- Commissioning record
- A documented verification that HVAC equipment, controls, ventilation rates, and safety devices operate as designed and meet OBC and manufacturer requirements.