OBC Small Buildings study materials
OBC Small Buildings study resources

OBC Small Buildings cheat sheet

OBC Small Buildings · Keep the key ideas within reach.

Quick reference

General Provisions

  • The building code applies to the design, construction, alteration, and demolition of buildings, and to plumbing, heating, and electrical systems.

  • A building permit is required before constructing, altering, or demolishing a building, unless the work is exempt under the code.

  • The most restrictive requirement governs when two or more code provisions conflict.

  • The owner is responsible for ensuring that the building and its systems comply with the code.

  • Equivalent alternative solutions may be accepted if they provide the same level of performance as the code.

  • The code does not apply retroactively to existing buildings unless a change of use or major alteration occurs.

  • Local amendments may modify the code; the stricter requirement applies where there is a conflict.

  • The code is intended to safeguard health, safety, and welfare, and to protect property from fire and structural failure.

Quick reference

Definitions and Administrative Requirements

  • The 'authority having jurisdiction' (AHJ) is the official responsible for enforcing the code.

  • A 'building' is any structure used or intended for supporting or sheltering any use or occupancy.

  • The 'floor area' is the area within the exterior walls of a building, measured to the inside surface of the walls.

  • The 'building height' is the vertical distance from grade to the highest point of the roof surface.

  • The 'occupant load' is the total number of persons for which the means of egress must be designed.

  • A 'permit' is an official document authorizing construction or alteration work.

  • A 'variance' is a grant of relief from a specific code requirement, subject to conditions.

  • The code official may inspect buildings at any reasonable time to verify compliance.

Quick reference

Building Classification

  • Buildings are classified by occupancy group based on the use or intended use of the building.

  • Major occupancy groups include Assembly (A), Business (B), Educational (E), Factory (F), High Hazard (H), Institutional (I), Mercantile (M), Residential (R), Storage (S), and Utility (U).

  • A building with multiple occupancies must comply with the most restrictive occupancy requirements unless separated by fire separations.

  • The occupancy classification determines the type of construction, fire protection, and means of egress requirements.

  • A change of use may require the building to comply with the requirements for the new occupancy.

  • Mixed occupancies must be separated by fire separations with a fire-resistance rating based on the occupancies involved.

  • The classification of a building is based on the occupancy and the building height and area limitations.

  • Accessory occupancies are ancillary to the main occupancy and do not change the overall building classification.

Quick reference

Occupancy and Construction Types

  • Construction types are classified by the fire-resistance rating of structural elements, from Type I (most restrictive) to Type V (least restrictive).

  • Type I and II construction require noncombustible materials for structural elements.

  • Type III construction permits combustible materials in interior elements but requires noncombustible exterior walls.

  • Type IV construction uses heavy timber structural elements with a specified minimum dimension.

  • Type V construction permits combustible materials for all structural elements.

  • The required type of construction depends on the occupancy group and the building's height and area.

  • Fire-resistance ratings for structural elements are expressed in hours (e.g., 1-hour, 2-hour).

  • The building's area and height may be increased with the installation of automatic sprinkler systems.

Quick reference

Fire Protection

  • Fire separations are required between different occupancies and between a building and an attached garage.

  • Fire-resistance ratings for fire separations are determined by the occupancy and the building's construction type.

  • Automatic sprinkler systems may be required based on the occupancy, building height, or area.

  • Smoke alarms are required in dwelling units and sleeping rooms.

  • Fire extinguishers must be provided in accordance with the code and maintained in working condition.

  • Standpipe and hose systems may be required in buildings based on height and occupancy.

  • Fire alarm systems must be installed and maintained to provide warning to occupants.

  • Fire protection systems must be inspected and tested periodically to ensure they remain functional.

Quick reference

Occupant Safety and Life Safety Systems

  • The occupant load is calculated using the floor area divided by the occupant load factor for the occupancy.

  • The occupant load determines the required number and width of exits.

  • Life safety systems include fire alarms, sprinklers, smoke control, and emergency lighting.

  • Emergency lighting must be provided in means of egress and other specified areas.

  • Exit signs must be illuminated and clearly visible from any point in the means of egress.

  • Smoke control systems may be required in large or high-hazard occupancies.

  • The fire safety plan must be prepared and maintained for the building.

  • Life safety systems must be tested and maintained in accordance with the code and standards.

Quick reference

Means of Egress and Exit Requirements

  • The means of egress comprises the exit access, the exit, and the exit discharge.

  • Every building must have at least one exit, and more exits are required based on occupant load and building height.

  • The minimum width of an exit is determined by the occupant load served.

  • Exit doors must swing in the direction of egress travel when serving an occupant load of 60 or more.

  • Exit doors must be equipped with panic hardware in assembly occupancies with an occupant load of 100 or more.

  • The travel distance to an exit must not exceed the maximum allowed for the occupancy.

  • Exit signs and emergency lighting are required in the means of egress.

  • The means of egress must be continuously maintained free of obstructions.

Quick reference

Structural Design and Load Requirements

  • Buildings and structural elements must be designed to support all applicable loads, including dead, live, snow, wind, and earthquake loads.

  • Dead loads are the weight of the building materials and fixed equipment.

  • Live loads are the weight of occupants, furniture, and movable equipment.

  • Snow loads are determined from the ground snow load for the location, adjusted for roof exposure and thermal factors.

  • Wind loads are determined from the basic wind speed for the location, adjusted for exposure and height.

  • Earthquake loads are determined from the seismic hazard for the location and the building's seismic design category.

  • The structural design must consider load combinations as specified in the code.

  • The foundation must be designed to support the building loads and transmit them to the ground safely.

Quick reference

Health, Sanitation and Building Services

  • Every dwelling unit must have a kitchen sink, a lavatory, a bathtub or shower, and a water closet.

  • Plumbing fixtures must be connected to an approved water supply and sanitary drainage system.

  • Each dwelling unit must have a means of ventilation, either natural or mechanical.

  • Heating systems must be capable of maintaining a minimum indoor temperature.

  • Natural light and ventilation are required for habitable rooms, unless mechanical systems are provided.

  • Sanitary facilities must be maintained in a clean and sanitary condition.

  • Garbage and refuse must be stored in approved containers and removed regularly.

  • Building services such as electrical, plumbing, and heating must be installed in accordance with the applicable codes.

Quick reference

Barrier-Free Accessibility Requirements

  • Accessible buildings must provide an accessible route from the exterior to the building entrance and throughout the building.

  • Accessible parking spaces must be provided and identified with the International Symbol of Access.

  • Ramps must have a maximum slope of 1:12 and landings at the top and bottom.

  • Accessible doors must have a minimum clear width of 32 inches (815 mm).

  • Accessible toilets must have a minimum clear floor space and grab bars installed.

  • Accessible lavatories must have a minimum clear floor space and knee clearance.

  • Accessible signage must include raised characters and Braille.

  • Accessible elevators must be provided in buildings with multiple stories, subject to specific exemptions.

Quick reference

Energy Efficiency and Environmental Separation

  • The building envelope must be designed to resist heat loss and gain in accordance with the energy code.

  • Insulation levels for walls, roofs, and floors are determined by the climate zone.

  • Windows and doors must have a maximum U-factor and solar heat gain coefficient.

  • Air leakage must be controlled by sealing penetrations and joints in the building envelope.

  • Environmental separation includes protection against moisture, soil gases, and sound transmission.

  • Vapour barriers must be installed on the warm side of the insulation to prevent condensation.

  • The building must be designed to prevent the accumulation of radon gas, where applicable.

  • Sound transmission between dwelling units must be controlled by separating assemblies.

Quick reference

Small Buildings: Part 9 Scope, Application and Construction Requirements

  • Part 9 applies to small buildings with a building area not exceeding 600 m² (6,460 ft²) and not more than three storeys in building height.

  • Part 9 buildings must also comply with the general requirements of Part 1 and other applicable Parts.

  • The foundation must extend below the frost line or be designed to prevent frost heave.

  • Footings must be at least 150 mm (6 in.) thick and extend at least 100 mm (4 in.) beyond the foundation wall.

  • Wood frame construction requires the use of approved fasteners and connectors.

  • Roof and floor joists must be sized in accordance with the spans and loads specified in the code.

  • Fire stopping must be provided at concealed spaces and penetrations in fire separations.

  • The building envelope must be designed to control the movement of heat, air, and moisture.