OBC Small Buildings key terms
OBC Small Buildings · Get comfortable with the vocabulary.
- Building Code Act
- Related: Chief Building Official, Building Permit
The provincial statute that authorizes a building code, establishes the powers of the chief building official, and sets out enforcement, inspection, and offence provisions for construction and demolition work.
- Chief Building Official
- Related: Building Permit, Order to Comply
The municipal officer appointed to administer and enforce the building code within a jurisdiction, including issuing permits, conducting inspections, and ordering compliance or remedial work.
- Building Permit
- Related: Chief Building Official, Permit to Occupy
Written municipal authorization to construct, alter, demolish, or change the use of a building, issued only after plans and specifications are reviewed for compliance with the code.
- Order to Comply
- Related: Stop-Work Order, Chief Building Official
A written direction from the building official requiring an owner or contractor to correct work that contravenes the code, stop unauthorized work, or provide information, within a stated time.
- Stop-Work Order
- Related: Order to Comply, Building Permit
A direction issued by the building official halting construction or demolition that is proceeding without a permit or in unsafe or non-compliant conditions until the deficiency is resolved.
- Major Occupancy
- Related: Building Classification, Occupancy Group
The principal use assigned to a building or part of it, such as residential, business, mercantile, or assembly, which drives the applicable fire safety and life safety requirements.
- Building Classification
- Related: Major Occupancy, Construction Type
The process of assigning a building to a category based on its major occupancy, height, area, and construction type, which determines the code requirements that apply.
- Construction Type
- Related: Combustible Construction, Noncombustible Construction
A code category describing the fire-resistance of structural and non-structural building elements, ranging from combustible conventional wood-frame construction to noncombustible protected assemblies.
- Combustible Construction
- Related: Noncombustible Construction, Construction Type
Construction in which structural members, walls, or floors are wholly or partly of wood or other combustible materials permitted by the code, typically subject to size and height limits.
- Noncombustible Construction
- Related: Combustible Construction, Fire-Resistance Rating
Construction in which the structural elements are of noncombustible material such as steel, concrete, or masonry, meeting the code's limits on combustibility of assemblies and finishes.
- Fire-Resistance Rating
- Related: Fire Separation, Closure
The period, in minutes or hours, for which a building element or assembly resists fire exposure while maintaining its separating or structural function, as determined by standardized testing.
- Fire Separation
- Related: Fire-Resistance Rating, Fire Compartment
A construction assembly that impedes the spread of fire and smoke between spaces, rooms, or buildings, and that has a fire-resistance rating where the code specifies one.
- Fire Compartment
- Related: Fire Separation, Fire-Resistance Rating
A space enclosed by fire separations and fire-rated structural elements that limits fire spread to a defined area, allowing limits on building area and occupant load to be applied.
- Closure
- Related: Fire Separation, Fire Door
A rated door, shutter, or other device installed in an opening in a fire separation to maintain the required fire protection when the opening is not in use.
- Fire Door
- Related: Closure, Fire Separation
A door assembly, including frame, hardware, and closer, tested and labeled for a stated fire-protection rating and installed in a rated opening in a fire separation.
- Occupant Load
- Related: Egress Width, Exit
The total number of persons for which a floor area or room is designed, calculated from the code's area-per-person values for the occupancy, and used to size exits and egress capacity.
- Means of Egress
- Related: Exit, Exit Access, Exit Discharge
A continuous, unobstructed path of travel from any point in a building to a public way, comprising the exit access, the exit, and the exit discharge.
- Exit
- Related: Means of Egress, Exit Access, Exit Discharge
That portion of a means of egress separated from other interior spaces by fire separations, providing a protected path to the exterior or to an exit discharge.
- Exit Access
- Related: Means of Egress, Exit
The part of a means of egress that leads from an occupied space to an exit, including corridors, aisles, and doorways, and subject to travel-distance and width limits.
- Exit Discharge
- Related: Means of Egress, Exit
The portion of a means of egress between the termination of an exit and a public way, such as an exterior passage, yard, or open area leading to the street.
- Egress Width
- Related: Occupant Load, Means of Egress
The clear width of corridors, stairs, and doorways serving an egress path, calculated from occupant load using code factors so that occupants can evacuate in reasonable time.
- Travel Distance
- Related: Exit Access, Means of Egress
The measured length of the egress path from the most remote point in a floor area to the nearest exit or exit stair, limited by the code according to occupancy and sprinkler protection.
- Dead-End Corridor
- Related: Exit Access, Travel Distance
A corridor segment with only one direction of escape, permitted only within the length limits set by the code unless it leads to an exit or is otherwise exempted.
- Dead Load
- Related: Live Load, Limit States Design
The permanent, stationary weight of a structure and its fixed components, including walls, floors, roofs, partitions, and permanently attached equipment, used in structural design calculations.
- Live Load
- Related: Dead Load, Limit States Design
The variable load imposed by occupancy and use, such as people, furniture, and stored goods, assigned by the code according to the intended use of each floor or roof area.
- Limit States Design
- Related: Dead Load, Live Load
A structural design method that checks specified load combinations against factored resistances for ultimate limit states and against serviceability criteria for deflection and vibration.
- Foundation
- Related: Footing, Load-Bearing Wall
The system of footings, piles, and walls that transfers building loads to the supporting soil, designed to keep settlement and bearing pressures within acceptable limits.
- Footing
- Related: Foundation, Load-Bearing Wall
The widened base of a foundation wall or column that distributes loads over a sufficient soil area to prevent excessive settlement or bearing failure.
- Load-Bearing Wall
- Related: Foundation, Footing
A wall that supports loads from floors, roofs, or other walls above and transfers them to the foundation, as distinguished from a non-load-bearing partition.
- Barrier-Free Design
- Related: Accessible Route, Clear Width
Design measures that allow persons with disabilities to approach, enter, and use a building and its facilities, including accessible routes, entrances, washrooms, and turning spaces.
- Accessible Route
- Related: Barrier-Free Design, Clear Width
A continuous, unobstructed path connecting accessible elements and spaces, meeting code requirements for width, slope, surface, and changes in level.
- Clear Width
- Related: Accessible Route, Egress Width
The unobstructed dimension of a passage, doorway, or fixture space measured between the nearest projecting surfaces, used to confirm accessibility and egress capacity.
- Thermal Resistance
- Related: Thermal Transmittance, Vapour Barrier
A measure of a material's ability to resist heat flow, expressed as an R-value, used to specify insulation and to evaluate the thermal performance of building envelope assemblies.
- Thermal Transmittance
- Related: Thermal Resistance, Vapour Barrier
The rate of heat flow through a unit area of an assembly per unit temperature difference, expressed as a U-value and equal to the reciprocal of the assembly's total thermal resistance.
- Vapour Barrier
- Related: Thermal Resistance, Air Barrier
A low-permeance membrane installed in an envelope assembly to limit moisture diffusion into the assembly, placed to keep condensation away from sensitive components.
- Air Barrier
- Related: Vapour Barrier, Thermal Resistance
A continuous system of materials that limits uncontrolled air leakage through the building envelope, reducing heat loss and preventing moisture-laden air from entering assemblies.
- Part 9 Scope
- Related: Prescriptive Requirement, Building Classification
The portion of the building code that governs small buildings, generally of three storeys or less and limited floor area, using prescriptive rules for construction, fire safety, and services.
- Prescriptive Requirement
- Related: Part 9 Scope, Alternative Solution
A code rule that states a specific, measurable solution, such as a minimum dimension or material specification, rather than a performance outcome the designer must demonstrate.
- Alternative Solution
- Related: Prescriptive Requirement, Chief Building Official
A design that meets the code's objectives through means other than the prescribed rules, accepted by the authority having jurisdiction on the basis of supporting analysis or documentation.