Power Eng 4th Class 4B study materials
Power Eng 4th Class 4B study resources

Power Eng 4th Class 4B cheat sheet

Power Eng 4th Class 4B · Keep the key ideas within reach.

Quick reference

Boilers and Boiler Fittings

  • A boiler is a closed pressure vessel in which water is heated to produce steam or hot water at pressures above atmospheric; ASME BPVC Section I governs power boilers, Section IV governs heating boilers.

  • Safety valve capacity must equal or exceed the maximum evaporating capacity of the boiler; the valve is set at or below the maximum allowable working pressure (MAWP) and is the final overpressure protection.

  • A try-cock or gauge glass gives the operator a direct water-level indication; the lowest visible level in the gauge glass must be at least 75 mm above the highest point of the heating surface for firetube boilers.

  • Three-element feedwater control uses steam flow, feedwater flow, and drum level signals to correct level without fighting swell or shrinkage during load changes.

  • Water column and gauge glass connections must be blown down daily; an obstructed water column can show a false level and lead to low-water trip or carryover.

  • A low-water fuel cutoff must be tested by evaporating or draining water while firing; the burner must shut off before the water drops below the safe limit.

  • Boiler efficiency (indirect method) = 100% minus stack losses, unburned carbon, moisture, and radiation losses; each 20 °C reduction in flue gas temperature raises efficiency roughly 1%.

  • Steam drum internals: cyclone separators remove bulk moisture, scrubbers remove fine droplets, and the dry pipe delivers steam with less than about 0.5% moisture.

Quick reference

Boiler Combustion and Draft Systems

  • Theoretical (stoichiometric) air for natural gas is about 9.5 m³ air per m³ gas; for fuel oil about 14 kg air per kg oil. Excess air is measured as O₂ in flue gas - typically 3% O₂ for gas, 4–5% for oil.

  • Flue gas O₂ and CO₂ are inversely related: as excess air rises, O₂ rises and CO₂ falls; a sudden CO rise signals incomplete combustion and possible flame impingement.

  • Draft is the pressure difference between the furnace and atmosphere; natural draft depends on stack height and temperature difference (Δp ≈ h × (ρ_air − ρ_gas) × g).

  • Forced draft fans pressurize the furnace; induced draft fans pull flue gas to the stack; balanced draft keeps the furnace slightly negative (about −0.05 to −0.1 kPa).

  • A flame scanner (UV or IR) detects flame presence; loss of flame signal must trip the fuel valve within the safety timing (typically 1 second for the main flame).

  • Purge before light-off: at least 5 air changes of the furnace and flue at 25–50% airflow to clear combustible gases before introducing fuel.

  • Fuel/air ratio control: a cross-limited control system prevents air from leading fuel on load increase and fuel from leading air on load decrease.

  • Combustion efficiency from flue gas: efficiency ≈ 100 − (stack loss) − (radiation); stack loss rises with flue gas temperature and excess air.

Quick reference

Boiler Feedwater Treatment and Control

  • External treatment removes impurities before the boiler: softeners exchange Ca²⁺/Mg²⁺ for Na⁺; demineralizers use cation and anion resins; reverse osmosis removes 95–99% of dissolved solids.

  • Internal treatment: phosphate or polymer programs precipitate or condition hardness; oxygen scavengers (sulfite or hydrazine) remove dissolved O₂; amines raise condensate pH.

  • Blowdown controls dissolved solids: continuous surface blowdown removes TDS, bottom blowdown removes sludge. Blowdown rate (%) ≈ (feedwater TDS / (boiler water TDS limit − feedwater TDS)) × 100.

  • Scale is the largest efficiency penalty: 1 mm of scale can raise fuel use by 5–10% because scale conductivity is about 1/40 that of steel.

  • Carryover causes superheater fouling and turbine deposits; causes include high TDS, high alkalinity, foaming, and sudden load swings.

  • pH control: boiler water pH 10.5–11.5 for steel protection; condensate pH 8.5–9.5 to limit CO₂ corrosion; below pH 8.5 indicates carbonic acid attack.

  • Silica limits depend on pressure: below 4 MPa about 150 mg/L; above 10 MPa below 0.5 mg/L to prevent silica carryover into steam.

  • A deaerator heats feedwater to saturation (about 105 °C at 0.12 MPa) and strips O₂ to below 0.005 mg/L; it also serves as the feedwater storage tank.

Quick reference

Pumps, Compressors, and Auxiliary Equipment

  • Centrifugal pump head H = (p_discharge − p_suction)/(ρg) + (v_d² − v_s²)/(2g) + Δz; flow varies with impeller speed per the affinity laws: Q ∝ N, H ∝ N², P ∝ N³.

  • NPSH available = (p_suction/(ρg) + v²/(2g)) − vapour pressure head; cavitation occurs when NPSH available falls below NPSH required.

  • Best efficiency point (BEP) is where a centrifugal pump should operate; running far left or right of BEP causes recirculation, vibration, and seal failure.

  • Positive displacement pumps deliver nearly constant flow against varying pressure; a relief valve on the discharge is mandatory because the pump can overpressure the line.

  • Reciprocating compressors use clearance volume; volumetric efficiency falls as clearance or pressure ratio rises. Multistage compression with intercooling reduces work.

  • Centrifugal compressors surge when flow falls below the surge line; anti-surge control recycles flow to protect the machine.

  • Fan laws mirror pump affinity laws: for a fan, Q ∝ N, static pressure ∝ N², power ∝ N³.

  • Air receiver sizing and aftercoolers: cooling compressed air to 40 °C condenses water; drains must be trapped to remove condensate without losing air.

Quick reference

Piping, Valves, and Steam Traps

  • Gate valves are for isolation (low pressure drop, not for throttling); globe valves are for throttling; check valves permit one-direction flow; ball and butterfly valves give quick quarter-turn isolation.

  • Safety relief valve set pressure is the MAWP; accumulation is normally limited to 10% above set pressure, and blowdown (reseating) is typically 4–7% below set.

  • Steam traps: thermodynamic (disc) traps for high-pressure drip legs; float-and-thermostatic traps for continuous condensate; inverted bucket traps for modulating loads; thermostatic traps for sensible heat removal.

  • A steam trap fails open = live steam loss; fails closed = waterlogging and water hammer. Test by ultrasonic, temperature, or sight-glass observation.

  • Pipe expansion: ΔL = L × α × ΔT; carbon steel α ≈ 0.012 mm/m·°C, so a 30 m line at 200 °C grows about 70 mm and needs expansion loops or slip joints.

  • Water hammer in steam lines comes from slug flow or rapid valve closure; prevention uses proper trapping, drainage at low points, and slow valve operation.

  • Steam pipe sizing: velocity limits are about 25–40 m/s for saturated steam mains and 40–60 m/s for superheated steam to limit erosion and pressure drop.

  • Pressure-reducing valves reduce steam pressure; a safety valve must be installed downstream of the PRV to protect the low-pressure side.

Quick reference

Heating, Ventilation, and Air Conditioning

  • Sensible heat Q = 1.2 × L/s × ΔT (W) for air at standard conditions; latent heat is from moisture, and total heat = sensible + latent.

  • Psychrometrics: dry-bulb, wet-bulb, dew point, relative humidity, and enthalpy. Relative humidity = (actual vapour pressure / saturation vapour pressure) × 100%.

  • Cooling coil apparatus dew point (ADP): air leaves near saturation; bypass factor = (leaving DB − ADP)/(entering DB − ADP).

  • Air changes per hour (ACH) = (airflow in m³/h) / (room volume in m³); typical comfort ventilation is 2–6 ACH, and kitchens need 10–15 ACH.

  • Duct friction loss is proportional to velocity squared; equal-friction and static-regain methods are used to size ducts, and velocity limits are about 5–8 m/s for supply mains.

  • Chilled water ΔT design is typically 5–7 °C; a low ΔT syndrome indicates poor coil heat transfer or bypass, and it raises pump energy.

  • Vapour-compression cooling cycle: evaporator → compressor → condenser → expansion valve; COP = refrigeration effect / compressor work.

  • Heating load includes transmission (U × A × ΔT) and infiltration (1.2 × L/s × ΔT); ventilation air adds both sensible and latent load.

Quick reference

Refrigeration Systems

  • Refrigeration capacity: 1 tonne of refrigeration = 3.517 kW = 12,000 Btu/h = heat to melt 1 tonne of ice in 24 h.

  • COP = refrigerating effect / work input; for a Carnot cycle COP = T_evap / (T_cond − T_evap), with temperatures in kelvin.

  • Subcooling liquid before the expansion valve increases refrigerating effect; superheating suction gas protects the compressor but reduces capacity if excessive.

  • Refrigerants: R-134a (GWP 1430), R-410A (GWP 2088), R-717 ammonia (GWP 0, toxic), R-744 CO₂ (GWP 1, high pressure); phase-out under the Montreal Protocol and Kigali Amendment.

  • An expansion valve controls superheat at the evaporator outlet; a flooded evaporator uses a float or level control instead.

  • Low suction pressure causes: restricted expansion valve, frosted coil, low charge, or blocked filter-drier. High discharge pressure causes: dirty condenser, non-condensables, or high ambient.

  • Refrigerant leaks: never use open flame to detect; use electronic detectors, soap bubbles, or UV dye. Ammonia is detected by its odour at 5 ppm.

  • Purging non-condensables from a condenser lowers discharge pressure and improves COP; air in the system raises head pressure and power draw.

Quick reference

Electrical Systems and Controls

  • Ohm's law V = I × R; power P = V × I × PF for AC single phase, and P = √3 × V × I × PF for three phase.

  • Three-phase motor current I = P / (√3 × V × PF × efficiency); a 15 kW, 400 V, 0.85 PF, 90% efficient motor draws about 28 A.

  • Motor protection: overload relays protect against sustained overcurrent; fuses and breakers protect against short circuit; the two functions must be coordinated.

  • Star-delta starting reduces starting current to one third of direct-on-line; soft starters and VFDs give smoother acceleration and energy savings on variable loads.

  • Motor insulation classes: B (130 °C), F (155 °C), H (180 °C); a Class F motor run at Class B rise has longer life.

  • Locked-rotor current is typically 6–8 times full-load current; voltage dip during starting can trip other equipment on the same bus.

  • Ground fault protection detects current returning outside the intended path; a 30 mA residual current device protects personnel, and 300 mA protects equipment.

  • VFD cable must be shielded and grounded at both ends to control high-frequency noise; long motor leads need dv/dt filters to protect winding insulation.

Quick reference

Instrumentation and Automatic Controls

  • A control loop has a sensor/transmitter, controller, and final control element; the error is setpoint minus measured variable.

  • PID control: proportional output = Kp × error; integral removes steady-state offset; derivative anticipates change and dampens overshoot.

  • Proportional band (%) = 100 / gain; a narrow band gives aggressive response and possible cycling; a wide band gives slow, stable response.

  • A 4–20 mA signal represents the process range; 4 mA is the live zero (zero percent) and 20 mA is 100%; a signal below 3.6 mA indicates a fault.

  • A thermocouple generates voltage from dissimilar metals; a resistance temperature detector (RTD) changes resistance with temperature and is more accurate and stable.

  • A transmitter calibrated 0–1000 kPa outputting 12 mA reads 500 kPa: value = (mA − 4)/16 × span + LRV.

  • Control valve fail-safe: air-to-open (fail-closed) or air-to-close (fail-open); the choice depends on whether the process is safer with the valve shut or open on air failure.

  • Loop tuning: Ziegler-Nichols ultimate gain method uses the proportional gain at which the loop cycles continuously (Ku) and the period (Pu) to set PID values.

Quick reference

Prime Movers and Engines

  • Four-stroke diesel cycle: intake, compression, power, exhaust; the camshaft turns at half crankshaft speed. Two-stroke engines fire every revolution and use scavenging ports.

  • Compression ratio = (swept volume + clearance volume) / clearance volume; diesel ratios are 12:1 to 22:1, and higher ratios raise thermal efficiency.

  • Indicated power (single cylinder) = (mean effective pressure × stroke × area × revolutions per second × number of power strokes per revolution).

  • Brake thermal efficiency = brake power output / fuel energy input; typical diesel values are 35–45%, and combined-cycle gas turbines reach 60%.

  • Detonation (knock) in spark-ignition engines is uncontrolled ignition; it is limited by octane rating, ignition timing, and compression ratio.

  • Diesel engines are rated by continuous brake power; a generator set must be sized with a margin for starting loads and altitude/temperature derating.

  • Gas turbines: compressor, combustor, turbine, and generator; the compressor absorbs 50–60% of turbine work, so efficiency depends on firing temperature and pressure ratio.

  • Engine cooling and lubrication: jacket water at 80–90 °C; lube oil pressure typically 200–400 kPa; low oil pressure must trip the engine.

Quick reference

Safety, Codes, and Environmental Protection

  • ASME Boiler and Pressure Vessel Code Section I (power boilers), Section IV (heating boilers), Section VIII (pressure vessels); CSA B51 covers boiler, pressure vessel, and piping code in Canada.

  • Boiler and Pressure Vessel Act requires periodic inspection and a valid certificate of inspection before operation; operating without one is an offence.

  • Confined space entry requires a permit, atmospheric testing (O₂ 19.5–23%, LEL below 10%, H₂S below 10 ppm), ventilation, attendant, and rescue plan.

  • Lockout/tagout: isolate all energy sources, verify zero energy, apply locks and tags by each worker; try the start button to confirm isolation.

  • WHMIS/GHS labels and safety data sheets (SDS) communicate chemical hazards; 16-section SDS format is standard.

  • Environmental limits: NOx from boilers is controlled by low-NOx burners, flue gas recirculation, and selective catalytic reduction; SO₂ is controlled by low-sulphur fuel or scrubbers.

  • Stack emissions monitoring: O₂, CO, NOx, and opacity; opacity is a visible measure of particulate, and continuous emission monitoring (CEM) may be required by permit.

  • Emergency response: a boiler low-water condition requires immediate fuel cutoff, no feedwater addition to a hot empty boiler, and controlled cooldown to avoid a brittle fracture.

Quick reference

Mathematics, Science, and Plant Calculations

  • Heat energy Q = m × c × ΔT; water c = 4.18 kJ/kg·°C; steam latent heat at atmospheric pressure is about 2257 kJ/kg.

  • Sensible and latent heat: total heat of steam h_g = h_f + h_fg; at 1 MPa, h_f ≈ 763 kJ/kg and h_fg ≈ 2015 kJ/kg.

  • Pressure conversions: 1 bar = 100 kPa = 14.5 psi; 1 atm = 101.325 kPa; gauge pressure = absolute pressure − atmospheric pressure.

  • Temperature conversion: °F = (°C × 9/5) + 32; K = °C + 273.15; always use absolute temperature in gas law calculations.

  • Ideal gas law PV = nRT; combined gas law P₁V₁/T₁ = P₂V₂/T₂ for a fixed mass; Boyle's law at constant T, Charles's law at constant P.

  • Boiler evaporation: 1 kg/h steam output requires about 1 kW of heat input at 100 °C feedwater and saturated steam; fuel input = output / efficiency.

  • Area and volume: pipe cross-section A = πd²/4; flow Q = A × v; tank volume = πr²h; 1 m³ = 1000 L.

  • Efficiency and cost: annual fuel cost = heat load / (efficiency × fuel heating value) × hours × fuel price; a 1% efficiency gain on a large boiler saves significant fuel.