Power Eng 4th Class 4B flashcards
Power Eng 4th Class 4B · Build recall with a focused review session.
32 cards. Read the term and the definition here. The deck at the top of this page is optional.
- MAWP
- Maximum allowable working pressure: the highest pressure at which a boiler or vessel may be operated, established by design calculations and stamped on the nameplate. Safety valves are set at or below this value.
- Three-element feedwater control
- A drum level control strategy using steam flow, feedwater flow, and drum level signals. It corrects level without instability from swell or shrinkage during sudden load changes.
- Low-water fuel cutoff
- A safety device that shuts off the burner when boiler water falls below the safe minimum level, preventing overheating and catastrophic failure of the heating surface.
- Excess air
- Air supplied above the theoretical amount needed for complete combustion. Measured as flue gas oxygen; too little causes CO and smoke, too much wastes heat up the stack.
- Balanced draft
- A furnace draft arrangement with both forced draft and induced draft fans, keeping the furnace slightly negative (about −0.05 to −0.1 kPa) so no hot gas escapes.
- Furnace purge
- A pre-ignition procedure passing air through the furnace and flue for at least five air changes to remove combustible gases before fuel is admitted.
- Blowdown rate
- The percentage of feedwater discharged to control dissolved solids, calculated as feedwater TDS divided by (boiler water TDS limit minus feedwater TDS), times 100.
- Deaerator
- A vessel that heats feedwater to saturation and strips dissolved oxygen to very low levels, typically below 0.005 mg/L, using steam and trays or spray nozzles.
- Scale
- Hard mineral deposit on boiler heating surfaces. It has very low thermal conductivity, so even 1 mm can raise fuel consumption by 5 to 10 percent.
- NPSH available
- The absolute suction head above vapour pressure available at the pump inlet. If it falls below NPSH required, cavitation occurs, causing noise, erosion, and loss of head.
- Affinity laws
- Pump and fan rules: flow varies with speed, head with speed squared, and power with speed cubed. Reducing speed to 80 percent cuts power to about 51 percent.
- Surge
- An unstable compressor condition at low flow where discharge pressure exceeds what the machine can sustain, causing flow reversal and violent vibration. Anti-surge control recycles flow.
- Gate valve
- A valve with a gate that moves perpendicular to flow. It gives low pressure drop for isolation service but should not be used for throttling because the gate erodes.
- Thermodynamic trap
- A steam trap using a disc that opens on high-velocity condensate and closes on flash steam. Common on high-pressure drip legs and tracing lines.
- Safety relief valve blowdown
- The pressure drop below set pressure at which a safety valve reseats, typically 4 to 7 percent of set pressure. Too little blowdown causes simmering and leakage.
- Water hammer
- A pressure surge caused by rapid velocity change in a pipe, such as sudden valve closure or slug flow of condensate. It can rupture fittings and supports.
- Relative humidity
- The ratio of actual water vapour pressure in air to the saturation vapour pressure at the same dry-bulb temperature, expressed as a percentage.
- Air changes per hour
- The number of times the total room air volume is replaced in one hour, calculated as airflow in cubic metres per hour divided by room volume in cubic metres.
- Bypass factor
- The fraction of air that passes a cooling coil without contacting the coil surface, calculated as (leaving dry-bulb minus apparatus dew point) divided by (entering dry-bulb minus apparatus dew point).
- Tonne of refrigeration
- A cooling capacity equal to 3.517 kilowatts, or 12,000 Btu per hour, the heat absorbed to melt one tonne of ice in 24 hours.
- Coefficient of performance
- Refrigeration effect divided by compressor work input. Higher COP means more cooling per unit of electrical energy. Carnot COP equals evaporator temperature divided by temperature lift, in kelvin.
- Subcooling
- Cooling liquid refrigerant below its condensing temperature before the expansion valve. It increases refrigerating effect and prevents flash gas at the valve inlet.
- Three-phase power
- Electrical power in a balanced three-phase circuit, calculated as the square root of three times line voltage times line current times power factor.
- Star-delta starting
- A motor starting method connecting windings in star for starting, then delta for run. It reduces starting current and torque to one third of direct-on-line values.
- Locked-rotor current
- The current a motor draws at standstill with rated voltage applied, typically six to eight times full-load current. It causes voltage dips during starting.
- Proportional band
- The percentage change in measured variable needed to drive the controller output from zero to full scale. It equals 100 divided by proportional gain; narrow bands cause cycling.
- Live zero
- The 4 mA minimum of a 4 to 20 mA current loop, representing zero percent of range. It allows a broken wire to be distinguished from a true zero reading.
- RTD
- A resistance temperature detector, usually platinum, whose resistance rises predictably with temperature. It is more accurate and stable than a thermocouple.
- Compression ratio
- The ratio of cylinder volume before compression to volume after compression, calculated as swept volume plus clearance volume divided by clearance volume.
- Brake thermal efficiency
- Brake power delivered at the shaft divided by the fuel energy input rate. Typical diesel engines achieve 35 to 45 percent.
- Lockout/tagout
- An energy isolation procedure in which each worker applies a personal lock and tag to the disconnect, then verifies zero energy before work begins.
- Heat equation
- The formula Q equals mass times specific heat times temperature change. For water the specific heat is 4.18 kilojoules per kilogram per degree Celsius.