Red Seal RV Service Technician · Get comfortable with the vocabulary.

Lockout/Tagout (LOTO)

A documented procedure for isolating all energy sources to a unit before service, applying personal locks and warning tags so equipment cannot be re-energized or started while a technician is working on it.

Related: Arc Flash Boundary, Personal Protective Equipment (PPE)
Arc Flash Boundary

The distance from exposed energized conductors within which a person could receive a second-degree burn from an arc; used to select approach distances and required protective equipment for 120/240 VAC RV service work.

Related: Lockout/Tagout (LOTO), Bonding and Grounding
Personal Protective Equipment (PPE)

Wearable gear such as safety glasses, gloves, arc-rated clothing, and hearing protection selected after a hazard assessment to reduce injury exposure during RV repair tasks.

Related: Arc Flash Boundary, Lockout/Tagout (LOTO)
Bonding and Grounding

Intentional connection of metal parts and the electrical system to earth so fault current has a low-impedance path back to the source, letting overcurrent devices open and limiting shock hazard.

Related: Ground Fault Circuit Interrupter (GFCI), Neutral-Ground Bond
Ground Fault Circuit Interrupter (GFCI)

A protective device that compares current on the hot and neutral conductors and trips when the difference indicates leakage, typically at 4 to 6 milliamps, protecting people from shock in wet locations.

Related: Bonding and Grounding, Receptacle Polarity
Neutral-Ground Bond

The single intentional connection between the grounded conductor and equipment grounding conductor, made at the source only; an RV must not have this bond because it is made at the shore power pedestal.

Related: Bonding and Grounding, Transfer Switch
Transfer Switch

A device that selects between shore power and an on-board generator so the two sources are never connected together, typically with a time delay to let the generator stabilize.

Related: Automatic Transfer Switch (ATS), Inverter/Converter
Inverter/Converter

A converter changes 120 VAC shore power into 12 VDC to charge batteries and run low-voltage loads; an inverter reverses the process, producing 120 VAC from a 12 VDC battery bank.

Related: Battery State of Charge, Transfer Switch
Battery State of Charge

The remaining capacity in a battery expressed as a percentage, estimated from resting voltage or a shunt-based monitor; it guides charging decisions and protects deep-cycle batteries from over-discharge damage.

Related: Inverter/Converter, Parasitic Draw
Parasitic Draw

Continuous low current drawn from the battery by devices such as clocks, detectors, and control boards when everything appears off; measured with a clamp meter to diagnose dead batteries.

Related: Battery State of Charge, Voltage Drop Test
Voltage Drop Test

A live measurement of the difference in voltage across a conductor or connection while current flows; excessive drop reveals resistance from corrosion or loose terminals that a static voltage check misses.

Related: Parasitic Draw, Bonding and Grounding
Manometer (U-Tube and Digital)

An instrument that measures LP gas pressure in inches of water column; used to verify regulated pressure at appliances and to perform timed leak-down tests on the piping system.

Related: Water Column (WC) Pressure, LP Gas Leak-Down Test
Water Column (WC) Pressure

The pressure unit used for LP gas, equal to the height of a water column it supports; RV appliance manifold pressure is typically 11 inches WC for LP and 10 inches WC for natural gas.

Related: Manometer (U-Tube and Digital), Two-Stage Regulator
Two-Stage Regulator

A regulator assembly that reduces tank pressure to about 10 psi in a first stage and then to appliance manifold pressure in a second stage, giving steadier delivery as tank pressure and load change.

Related: Water Column (WC) Pressure, LP Gas Leak-Down Test
LP Gas Leak-Down Test

A timed pressure test in which the LP system is pressurized and isolated, then observed on a manometer; a pressure drop beyond the allowed limit indicates a leak requiring repair before service.

Related: Manometer (U-Tube and Digital), Two-Stage Regulator
Thermocouple and Thermopile

Sensors that generate a small voltage from heat to prove a pilot flame is lit; the thermocouple holds a single pilot-operated valve open, while a thermopile powers the main valve in millivolt systems.

Related: Flame Rectification, Combustion Air
Flame Rectification

The principle by which a direct spark ignition control senses a flame: the flame conducts current in one direction between the igniter/sensor and burner, producing a microamp signal the board reads as proof of ignition.

Related: Thermocouple and Thermopile, Combustion Air
Combustion Air

The air supplied to a burner for complete combustion; blocked or inadequate supply causes sooting, carbon monoxide production, and flame rollout, so appliance venting and openings must stay clear.

Related: Flame Rectification, Carbon Monoxide (CO) Safety
Carbon Monoxide (CO) Safety

Recognition that CO is colorless and odorless, and that cracked heat exchangers, blocked flues, or reversed draft can cause poisoning; testing with a CO analyzer and verifying draft are required after repairs.

Related: Combustion Air, Flame Rectification
P-Trap and Air Admittance Valve

A water seal in the drain line that blocks holding tank odors from entering the coach; an air admittance valve lets air in behind draining water without allowing sewer gas out.

Related: Black Water Tank Flush, Waste Valve (Blade Valve)
Black Water Tank Flush

A built-in spray nozzle or external fitting that rinses the inside of the black tank after dumping, helping remove solids and sensor fouling; it must be connected through a vacuum breaker to prevent backflow.

Related: P-Trap and Air Admittance Valve, Waste Valve (Blade Valve)
Waste Valve (Blade Valve)

A sliding gate valve on the gray or black tank outlet that opens to dump contents; a leaking seal or debris in the track causes slow seepage and must be serviced before the valve is left closed.

Related: Black Water Tank Flush, P-Trap and Air Admittance Valve
Fresh Water Pump and Accumulator

A demand pump pressurizes the potable system and shuts off at a set pressure; an accumulator tank absorbs pressure pulses, reducing pump cycling and stabilizing flow at fixtures.

Related: Winterization and Antifreeze, P-Trap and Air Admittance Valve
Winterization and Antifreeze

Preparing the water system for freezing weather by draining lines, water heater, and tanks, then filling with potable antifreeze or blowing with air so trapped water cannot expand and split pipes or fittings.

Related: Fresh Water Pump and Accumulator, Water Heater Bypass Valve
Water Heater Bypass Valve

A valve arrangement that isolates the water heater from the plumbing so it can be drained or bypassed during winterization, saving antifreeze and preventing damage from a dry-fired tank.

Related: Winterization and Antifreeze, Flame Rectification
Superheat and Subcooling

Superheat is refrigerant temperature above saturation at the evaporator outlet; subcooling is temperature below saturation at the condenser outlet. Together they show charge and metering-device performance.

Related: Refrigerant Recovery, Combustion Air
Refrigerant Recovery

Removing refrigerant from a sealed system into a recovery cylinder before opening it, as required by regulation; venting to atmosphere is prohibited and recovered refrigerant is weighed and recorded.

Related: Superheat and Subcooling, Personal Protective Equipment (PPE)
Laminated vs. Filon Roofing

Roof coverings differ: EPDM and TPO are single-ply rubber or thermoplastic membranes, while fiberglass-reinforced panels are rigid; each accepts only compatible sealants and cleaners to avoid damage.

Related: Roof Lap Sealant, Dicor Self-Leveling Sealant
Roof Lap Sealant

A bead of sealant applied over fasteners, seams, and roof penetrations to shed water; it must match the membrane type and be inspected and refreshed as it cracks or lifts.

Related: Laminated vs. Filon Roofing, Dicor Self-Leveling Sealant
Dicor Self-Leveling Sealant

A pourable sealant that flows out to form a smooth cap over horizontal roof seams and around vents; used on EPDM and TPO roofs where a flat, water-shedding surface is needed.

Related: Roof Lap Sealant, Laminated vs. Filon Roofing
Delamination

Separation of the exterior sidewall or roof skin from the substrate, often caused by water intrusion; detected by tapping for a hollow sound and by bulging, and it weakens structure and invites rot.

Related: Roof Lap Sealant, Weight Distribution Hitch
Weight Distribution Hitch

A hitch system using spring bars to transfer tongue weight to the trailer and front axle of the tow vehicle, leveling the combination and restoring steering and braking stability.

Related: Tongue Weight and Payload, Sway Control
Tongue Weight and Payload

Tongue weight is the downward load at the coupler, generally 10 to 15 percent of trailer weight; payload is the cargo and passenger capacity remaining after the tow vehicle's own weight.

Related: Weight Distribution Hitch, Gross Vehicle Weight Rating (GVWR)
Gross Vehicle Weight Rating (GVWR)

The maximum allowable total weight of a vehicle or trailer including cargo, fluids, and passengers as set by the manufacturer; exceeding it overloads tires, axles, and brakes.

Related: Tongue Weight and Payload, Sway Control
Sway Control

A device or electronic system that resists trailer yaw caused by crosswinds, passing vehicles, or improper loading, helping keep the combination straight and preventing loss of control.

Related: Weight Distribution Hitch, Gross Vehicle Weight Rating (GVWR)
Slide-Out Seal and Wiper

The bulb and wiper seals around a slide room opening that keep water and debris out; worn or torn seals allow intrusion and must be replaced and lubricated with compatible products.

Related: Slide-Out Synchronization, Delamination
Slide-Out Synchronization

Keeping both sides of a slide room moving together; on electric and hydraulic systems, out-of-sync travel causes binding and damage, corrected by a manufacturer-specific re-timing procedure.

Related: Slide-Out Seal and Wiper, Hydraulic Leveling System
Hydraulic Leveling System

A pump-and-cylinder system that extends jacks to level the coach; it requires checking fluid level with jacks retracted, bleeding air, and confirming the park brake interlock before operation.

Related: Slide-Out Synchronization, Lockout/Tagout (LOTO)
Customer Concern Verification

Reproducing and documenting the customer's reported symptom before repair, then confirming the fix under the same conditions; this prevents unnecessary parts replacement and supports a defensible repair order.

Related: Voltage Drop Test, Combustion Air