Lockout/tagout (LOTO)

A formal procedure that isolates every energy source feeding a system, applies a personal lock and tag, and verifies zero energy before work begins. It prevents accidental start-up or release of stored pressure, water, or electricity during maintenance.

Related: Impairment permit, Confined space entry
Impairment permit

A written authorization that documents a fire protection system taken out of service, the compensating measures put in place, and the person responsible. It coordinates notification of the fire department, building occupants, and the authority having jurisdiction until the system is restored.

Related: Lockout/tagout (LOTO), Authority having jurisdiction (AHJ)
Confined space entry

Entry into a tank, vault, pit, or similar space with limited access and poor natural ventilation. Work requires atmospheric testing, an attendant outside, rescue provisions, and a permit where the space is classified as permit-required.

Related: Lockout/tagout (LOTO), Impairment permit
Personal protective equipment (PPE)

Safety gear worn by the fitter, such as eye protection, gloves, hearing protection, and respiratory protection. Selection follows a hazard assessment of the tasks performed, including cutting, grinding, threading, and working at height.

Related: Fall protection, Hot work permit
Fall protection

Systems and procedures that prevent or arrest a fall from an elevated work surface. Common measures include guardrails, personal fall arrest harnesses with lanyards, and safe ladder practices, chosen according to the height and exposure.

Related: Personal protective equipment (PPE)
Hot work permit

A document authorizing welding, cutting, grinding, or other spark-producing work in an area where combustible materials or flammable vapours may be present. It records fire watch, area clearance, and the precautions taken before and after the task.

Related: Personal protective equipment (PPE)
Authority having jurisdiction (AHJ)

The organization, office, or individual responsible for approving equipment, installations, and procedures under the applicable code. The AHJ may be a municipal fire official, building department, or insurer with delegated enforcement authority.

Related: Impairment permit, Acceptance test
Hydraulic calculation

A pressure-and-flow analysis that determines the water demand of the most remote sprinkler area and verifies that the supply can meet it. It accounts for elevation, friction loss in pipe and fittings, and device losses along the path.

Related: Remote area, Friction loss, Safety margin
Remote area

The hydraulically most demanding set of sprinklers that must be calculated to flow simultaneously. Its size in square metres or square feet depends on occupancy hazard and system type, and it establishes the design demand.

Related: Hydraulic calculation, Design density
Design density

The minimum water flow rate, expressed in millimetres per minute or gallons per minute per square foot, that must be delivered over a specified floor area. It is selected from the occupancy hazard classification and forms the basis of the hydraulic calculation.

Related: Remote area, Hydraulic calculation, Occupancy hazard classification
Friction loss

Pressure lost as water moves through pipe, fittings, and devices because of turbulence and resistance at the pipe wall. It is estimated with a friction loss formula or tables and grows with flow rate and with smaller internal diameters.

Related: Hydraulic calculation, C-factor (Hazen-Williams)
C-factor (Hazen-Williams)

A coefficient describing the internal roughness of a pipe in the Hazen-Williams friction loss formula. Smoother pipe such as cement-lined or plastic has a higher value and loses less pressure than older unlined steel.

Related: Friction loss, Hydraulic calculation
Safety margin

The extra pressure or flow kept in reserve above the calculated system demand so that the water supply is adequate without relying on its exact limit. It accounts for supply fluctuations, aging, and future changes.

Related: Hydraulic calculation, Water flow test
Water flow test

A field test that measures static and residual pressure at a hydrant or test outlet while a known flow is discharged. The results, plotted on a graph, estimate the available supply for the sprinkler system design.

Related: Safety margin, Hydraulic calculation
Occupancy hazard classification

A grouping of occupancies by the amount and combustibility of their contents and the expected heat release. The class, such as light, ordinary, or extra hazard, determines design density, sprinkler spacing, and hose allowance.

Related: Design density, Remote area
Pipe schedule method

A prescriptive approach that sets minimum pipe sizes for a given number of sprinklers, based on tables rather than calculation. It is limited to defined system sizes and occupancies and cannot be used for every installation.

Related: Hydraulic calculation
Working pressure

The pressure a component or pipe is designed to withstand in normal service, including the maximum expected system pressure. Components are selected and rated against this value, with allowances for surge or test pressure.

Related: Hydrostatic test, Pressure rating
Grooved coupling

A mechanical pipe joint that grips rolled or cut grooves near the pipe ends with a gasket and clamp assembly. It permits limited movement and faster assembly than welding, and must be listed for fire protection service.

Related: Threaded joint, Hanger spacing
Threaded joint

A connection made by cutting tapered threads on pipe ends and tightening them into fittings, using listed sealant or tape. Thread engagement and lubrication must match the standard so the joint seals and resists pressure.

Related: Grooved coupling, Working pressure
Hanger spacing

The maximum permitted distance between supports along a run of sprinkler pipe, set by pipe size, material, and whether the pipe is above or below sprinklers. Supports carry the weight of pipe and water and control movement.

Related: Seismic bracing, Grooved coupling
Seismic bracing

Lateral and longitudinal restraints that keep sprinkler piping from swinging or separating during an earthquake. Bracing is required in defined seismic zones and is spaced according to pipe size and the building structure.

Related: Hanger spacing, Sway brace
Sway brace

A diagonal member anchored to the building structure that resists lateral movement of sprinkler piping. It works with flexible couplings and clearances that allow the pipe to move without damage at penetrations.

Related: Seismic bracing, Hanger spacing
Sprinkler temperature rating

The nominal temperature at which a sprinkler's heat-responsive element operates, selected above the maximum expected ceiling temperature of the space. Ratings are colour-coded and range from ordinary to high-temperature links.

Related: Sprinkler K-factor, Response time index (RTI)
Sprinkler K-factor

A discharge coefficient relating flow from a sprinkler to the square root of supply pressure. A larger K-factor delivers more water at the same pressure, and it must match the design calculation.

Related: Design density, Sprinkler temperature rating
Response time index (RTI)

A measure of how quickly a sprinkler's thermal element reacts to a growing fire. Lower values indicate faster response, and the index helps classify sprinklers as quick, standard, or special response for design purposes.

Related: Sprinkler temperature rating, Sprinkler K-factor
Deflector position

The distance and orientation of the sprinkler deflector relative to the ceiling or wall, which shapes the spray pattern. Incorrect position, caused by obstruction or misinstallation, can prevent water from reaching the fire.

Related: Obstruction rule, Sprinkler K-factor
Obstruction rule

Requirements that keep the spray pattern clear of beams, ducts, and other objects by defining maximum distances and required additional sprinklers. The aim is to prevent shadowed areas where fire could grow unchecked.

Related: Deflector position
Dry pipe valve

A valve that holds air pressure on the system side and water on the supply side, opening when a sprinkler releases air. It keeps water out of piping exposed to freezing and must trip at the correct air-to-water pressure differential.

Related: Preaction system, Waterflow alarm switch
Preaction system

A dry system in which a detection device must operate before water enters the piping, protecting sensitive areas from accidental discharge. It may be single-interlock or double-interlock, the latter requiring two independent signals.

Related: Dry pipe valve, Waterflow alarm switch
Waterflow alarm switch

A device that senses sustained water movement in the system and triggers an alarm. It is set to avoid false alarms from surges and is tested as part of the acceptance and periodic inspection routine.

Related: Dry pipe valve, Acceptance test
Check valve

A valve that allows flow in one direction only and closes automatically against reverse flow. In fire protection it prevents backflow, protects the public supply, and separates zones or risers.

Related: Backflow preventer, Riser
Backflow preventer

An assembly that stops contaminated water from reversing into the potable supply. It is required where cross-connection risk exists and must be tested and inspected on a scheduled basis.

Related: Check valve, Riser
Riser

The vertical pipe that carries water from the supply main to the sprinkler piping on each floor. It often includes the main control valve, alarm devices, and test connections, and it identifies the system on drawings.

Related: Check valve, Riser nipple
Fire pump

A dedicated pump that boosts water pressure and flow to meet sprinkler demand when the public supply is insufficient. It is controlled by pressure switches and must be tested to confirm its rated performance curve.

Related: Churn test, Suction supply
Churn test

A no-flow run of a fire pump that checks it operates at shutoff condition without overheating or excessive pressure. The results are compared with the manufacturer's curve and recorded as part of acceptance testing.

Related: Fire pump, Acceptance test
Suction supply

The water source feeding a fire pump, such as a tank, reservoir, or city main, including the piping and fittings that deliver it. Adequate suction conditions prevent cavitation and ensure the pump reaches its rated flow.

Related: Fire pump, Water flow test
Acceptance test

The documented verification, witnessed by the authority having jurisdiction where required, that a newly installed system performs as designed. It includes hydrostatic and flow tests, alarm checks, and confirmation that the installed system matches the approved plans.

Related: Hydrostatic test, Authority having jurisdiction (AHJ)
Hydrostatic test

A pressure test of piping performed with water, held at a specified pressure for a set duration to reveal leaks and weak joints. It is done before concealment and results are recorded for the acceptance package.

Related: Working pressure, Acceptance test
Flushing

Cleaning debris, scale, and foreign material from piping by passing water through it before connection to sprinklers or devices. Proper flushing prevents clogged heads and blocked valves at the time of a fire.

Related: Acceptance test, Hydrostatic test
As-built drawing

A drawing revised after installation to show the system as actually constructed, including routing changes and added devices. It is handed over with test records so future inspectors and maintenance staff can work from accurate information.

Related: Acceptance test, Riser