Fire tetrahedron
Model of combustion requiring fuel, oxidizer, heat, and an uninhibited chemical chain reaction; removing any one component stops the fire.
Lower flammable limit
The minimum fuel concentration in air that will support combustion; below this limit the mixture is too lean to ignite.
Flash point
The lowest temperature at which a liquid releases enough vapor to form an ignitable mixture near its surface, though burning may not continue.
Class D fire
A fire involving combustible metals such as magnesium, titanium, or sodium; requires a special dry powder agent, not water.
Flashover
The transition from growth to fully developed fire, when radiant heat ignites all combustible surfaces in the compartment nearly simultaneously.
Autoignition temperature
The temperature at which a material ignites spontaneously without an external pilot source; it is above the flash point for liquids.
Photoelectric detector
A smoke detector that senses light scattered by smoke particles; it responds faster to smoldering fires producing larger particles.
Ionization detector
A smoke detector that senses current change when smoke enters its ionization chamber; it responds faster to flaming fires with small particles.
Addressable alarm system
A system in which each initiating and notification device has a unique address, allowing annunciation of the specific device in alarm.
Supervisory signal
A signal indicating an off-normal condition that impairs protection, such as a closed control valve or loss of supervision.
Trouble signal
A signal indicating a fault in the system itself, such as an open circuit, ground fault, or low battery, distinct from alarm.
Notification appliance circuit
The circuit that powers audible and visible signaling devices; it is designed to meet code requirements for audibility and visibility.
Wet chemical agent
A potassium-based extinguishing agent that saponifies cooking oils and is standard for Class K kitchen hood suppression systems.
Clean agent
A gaseous extinguishing agent such as FM-200 or an inert gas that suppresses fire with minimal residue and no electrical conductivity.
Wet-pipe sprinkler system
A sprinkler system with water under pressure in the piping at all times; it discharges immediately when a sprinkler activates.
Dry-pipe sprinkler system
A sprinkler system holding pressurized air in the piping; the air escapes first, then water flows, allowing use in freezing environments.
Sprinkler discharge density
The water flow rate per unit area (gpm/ft²) applied over the design area; a primary hydraulic design parameter for sprinkler systems.
Class K extinguisher
An extinguisher using wet chemical agent for fires involving cooking oils and fats in commercial cooking equipment.
Means of egress
A continuous, unobstructed path of travel from any point in a building to the public way, comprising exit access, exit, and exit discharge.
Occupant load
The number of persons for which a space is designed, calculated from floor area divided by the occupant load factor for the use.
Travel distance
The measured distance from the most remote point in a space to the nearest exit, limited by occupancy and sprinkler protection.
Dead-end corridor
A corridor segment with only one direction of travel to an exit; length is limited by code to prevent occupants being trapped.
Area of refuge
A protected space in a building where occupants who cannot use stairs can wait safely for assistance during evacuation.
NFPA 13
The standard for the installation of sprinkler systems, covering design, hydraulic calculation, spacing, and acceptance testing requirements.
Hot work permit
A document authorizing welding, cutting, or grinding after verifying fire precautions, including a fire watch during and after the work.
ITM interval
The required frequency for inspection, testing, and maintenance of fire protection systems, set by the applicable NFPA standard.
Occupancy classification
The category assigned to a building or space based on its use, which determines construction type, height, area, and fire protection requirements.
Impairment procedure
The process of notifying the authority and occupants, posting signage, and providing interim measures when fire protection is out of service.
Incident Command System
A standardized organizational structure for emergency response with command, operations, planning, logistics, and finance/administration functions.
PASS technique
The extinguisher procedure: Pull the pin, Aim at the base of the fire, Squeeze the handle, and Sweep side to side.
RACE sequence
The emergency action sequence: Rescue, Alarm, Confine, and Extinguish or Evacuate, prioritizing occupant safety before firefighting.
Pre-incident plan
A document prepared before an emergency that identifies access, hydrants, utilities, hazards, and occupancy details for responders.