SCO Fire study materials
SCO Fire study resources

SCO Fire key terms

SCO Fire · Get comfortable with the vocabulary.

Flashover

The sudden transition to full-room fire involvement, when heat radiated from the ceiling and hot gas layer ignites nearly all exposed combustible surfaces at once.

Related: Thermal Layering, Backdraft, Pyrolysis
Backdraft

A violent ignition of accumulated unburned fuel gases that occurs when oxygen suddenly enters an oxygen-depleted, hot, smoke-filled compartment.

Related: Flashover, Neutral Plane
Pyrolysis

Chemical decomposition of a solid material driven by heat, releasing combustible gases before visible flame ever appears on the surface.

Related: Flashover, Ignition Temperature
Fire Tetrahedron

The four elements needed for flaming combustion: fuel, oxygen, heat, and the uninhibited chemical chain reaction that sustains the flame.

Related: Class B Fire, Clean Agent
Thermal Layering

Stratification of fire gases in a compartment, with hot smoke collecting at the ceiling and cooler air remaining near the floor.

Related: Neutral Plane, Flashover
Neutral Plane

The horizontal boundary in a smoke-filled compartment separating the upper hot gas layer from the lower cooler, clearer air layer.

Related: Thermal Layering, Backdraft
Class B Fire

A fire involving flammable or combustible liquids, such as gasoline, oil, or solvents, where a smothering or foam blanket is usually required.

Related: Class K Fire, Fire Tetrahedron
Class K Fire

A fire in cooking oils or fats in commercial cooking equipment, requiring a wet chemical agent that saponifies the burning oil.

Related: Class B Fire, Wet Chemical System
Ignition Temperature

The lowest temperature at which a material will continue to burn on its own once an external ignition source is removed.

Related: Pyrolysis, Flammable Limit
Flammable Limit

The upper or lower concentration of fuel vapor in air that will support combustion; outside this range the mixture is too lean or too rich to burn.

Related: Ignition Temperature, Vapor Density
Smoke Detector

A device that senses combustion products such as visible smoke or aerosols and sends a signal to the fire alarm control unit.

Related: Spot-Type Detector, Addressable System, Notification Appliance
Spot-Type Detector

A detector that monitors a limited area around its mounting location, as opposed to sampling air from a wide or extended space.

Related: Smoke Detector, Duct Detector
Duct Detector

A detector installed in an HVAC duct that senses smoke moving through the air handling system and typically shuts down the unit.

Related: Spot-Type Detector, Smoke Detector
Addressable System

A fire alarm architecture in which each initiating device has a unique identifier, letting the panel report the exact device in alarm.

Related: Conventional System, Notification Appliance
Conventional System

A fire alarm arrangement where devices share a circuit or zone, so the panel reports only the zone rather than the individual device.

Related: Addressable System
Notification Appliance

A device such as a horn, speaker, or strobe that alerts occupants of a fire alarm condition through audible or visible signals.

Related: Voice Evacuation System, Addressable System
Voice Evacuation System

An emergency communication arrangement that delivers live or prerecorded spoken instructions to occupants instead of only a tone or horn.

Related: Notification Appliance, Area of Refuge
Wet Pipe Sprinkler System

An automatic sprinkler system with water held under pressure in the piping at all times, discharging immediately when a sprinkler operates.

Related: Dry Pipe System, Sprinkler Head
Dry Pipe System

A sprinkler system with pressurized air or nitrogen in the piping and water held back by a valve, used where freezing is a concern.

Related: Wet Pipe Sprinkler System, Pre-Action System
Pre-Action System

A sprinkler arrangement requiring a detector signal to admit water into the piping before a sprinkler head operates, limiting accidental discharge.

Related: Dry Pipe System, Sprinkler Head
Sprinkler Head

A heat-actuated discharge device that opens at a rated temperature, releasing water in a designed spray pattern over a protected area.

Related: Wet Pipe Sprinkler System, Sprinkler K-Factor
Sprinkler K-Factor

A numerical rating of a sprinkler's discharge coefficient that relates water flow to the square root of pressure at the head.

Related: Sprinkler Head
Clean Agent

A gaseous extinguishing medium that leaves no residue and works mainly by interrupting the chemical chain reaction or by cooling.

Related: Fire Tetrahedron, Carbon Dioxide System
Carbon Dioxide System

A suppression system using CO2 to displace oxygen and cool the fire, hazardous to people because it is an asphyxiant in enclosed spaces.

Related: Clean Agent, Wet Chemical System
Wet Chemical System

A fixed system using an alkaline solution that reacts with burning cooking fats to form a smothering soap-like foam.

Related: Class K Fire, Carbon Dioxide System
Means of Egress

The continuous and unobstructed path of travel from any point in a building to a public way, comprising exit access, exit, and exit discharge.

Related: Exit Access, Exit Discharge, Travel Distance
Exit Access

The portion of the egress path that leads from an occupied space to the entrance of an exit, such as a corridor or aisle.

Related: Means of Egress, Exit Discharge
Exit Discharge

The part of the means of egress between the termination of an exit and a public way, such as an exterior walkway or courtyard.

Related: Means of Egress, Exit Access
Travel Distance

The measured length of the egress route from the most remote point in a space to an exit, limited by code according to occupancy.

Related: Means of Egress, Common Path of Travel
Common Path of Travel

The distance a person must travel before reaching a point where two separate routes to exits become available.

Related: Travel Distance, Means of Egress
Area of Refuge

A designated space protected from fire and smoke where people unable to use stairs can wait safely for assisted evacuation.

Related: Means of Egress, Voice Evacuation System
Occupant Load

The calculated number of people a space is designed to hold, derived from floor area and occupancy-based density factors.

Related: Travel Distance, Means of Egress
Fire Resistance Rating

The period, in hours or minutes, that a building element withstands a standard fire test while maintaining its separating or structural function.

Related: Fire Barrier, Fire Partition
Fire Barrier

A fire-resistance-rated wall or assembly with protected openings that restricts fire spread and typically must remain continuous through concealed spaces.

Related: Fire Partition, Fire Resistance Rating
Fire Partition

A rated wall with a lower fire-resistance rating than a fire barrier, usually used to separate dwelling units or corridors within a building.

Related: Fire Barrier, Fire Resistance Rating
Hot Work Permit

A written authorization issued before welding, cutting, or other spark-producing work, documenting fire watch, area preparation, and equipment checks.

Related: Fire Watch, Pre-Incident Plan
Fire Watch

A person assigned to patrol an area for fire conditions and provide early notification, often required when protection systems are impaired.

Related: Hot Work Permit, Impairment
Impairment

A condition in which a fire protection system or feature is out of service or degraded, requiring notification, mitigation, and often a fire watch.

Related: Fire Watch, Hot Work Permit
Pre-Incident Plan

A document assembled in advance describing a building's layout, hazards, access, utilities, and suppression resources to guide emergency operations.

Related: Incident Action Plan, Fire Watch
Incident Action Plan

A written or verbal statement of objectives, strategies, and tactics that guides responders for an operational period of an incident.

Related: Pre-Incident Plan, Fire Watch