TSSA Gas Technician 2 (G2) study plan
TSSA Gas Technician 2 (G2) · Give each week a clear focus.
8 weeks · About 6 hours per week
Gas fundamentals and properties of gases
Define the measurable physical properties of natural gas and propane (relative density, heating value ranges, Wobbe index, flammability limits, ignition temperature) and state how each affects appliance operation
Convert between imperial and SI units for pressure, heat input, gas rate, and specific gravity without reference aids
Explain the relationship between pressure, gas rate, and orifice size, and predict what happens to burner input when supply pressure changes
Describe complete and incomplete combustion and identify the products and symptoms of each in a gas appliance
Your checkpoint
One-page reference sheet of gas properties and unit conversions, self-quizzed to 90% accuracy on 20 recall items
Gas fundamentals and properties of gases & Venting, combustion air and appliance installation
Calculate combustion air requirements for a given appliance input and room volume, and determine whether a confined space needs two permanent openings
Explain draft, spillage, and the difference between natural draft, induced draft, and power-vented appliances
Trace the path of flue gases through a Category I through IV appliance and justify why each category needs its venting approach
Identify the signs of depressurization and spillage in a residential setting and state the test that confirms each
Your checkpoint
Worked solution set of five combustion air and venting calculations with reasoning shown for each step
Codes, regulations and standards
Locate and read the clauses governing installation clearances, venting, and piping in the current Canadian gas installation code and the applicable provincial regulation
Distinguish the roles of the national code, the provincial regulation, the CSA certification mark, and the manufacturer's installation instructions when requirements conflict
List the approval and notification steps a G2 holder must follow before and after installing or altering an appliance
Identify the documentation an inspector may request at each stage of a job
Your checkpoint
Annotated clause index of 15 code sections with a one-line summary of what each controls
Codes, regulations and standards & Installation of gas piping and tubing systems
Size a natural gas and a propane piping run using the pipe sizing tables, including equivalent length for fittings and allowable pressure drop
Select between steel pipe, copper tubing, and corrugated stainless steel tubing for a given application and justify the choice against code and material limits
Describe required support spacing, protection from physical damage, and the rules for concealed and underground runs
Explain bonding and grounding requirements for gas piping and why they matter
Your checkpoint
Completed pipe sizing worksheet for a two-appliance residential layout, showing equivalent lengths and selected sizes
Installation of gas piping and tubing systems
Lay out a piping system from meter to appliances including drip legs, sediment traps, shutoff valves, and union locations
Specify the leak test procedure for a new installation: test medium, pressure, duration, and what constitutes a pass
Identify the correct method for joining each material type and the inspection points a code officer would check
Diagnose three common piping faults (undersized run, missing sediment trap, improper concealed joint) and state the corrective action for each
Your checkpoint
Hand-drawn isometric piping plan with a written leak test procedure and pass criteria
Venting, combustion air and appliance installation
Verify vent connector slope, rise, termination clearance, and liner requirements for a specified appliance and building configuration
Determine whether an existing chimney or vent can accept a new appliance and identify when relining or resizing is required
Check combustion air, clearance to combustibles, and accessibility against manufacturer's instructions for two sample appliances
Explain the risks of common venting and backdrafting and the field tests that reveal them
Your checkpoint
Venting compliance checklist applied to two sample installations, with a pass/fail verdict and cited reason for each item
Testing, commissioning, servicing and troubleshooting
Perform and record a clock-dial gas rate test and a manifold pressure test, and interpret results against the appliance rating plate
Describe the startup sequence and safety checks for a newly installed appliance, including purging, pilot and ignition verification, and limit and safety switch testing
Build a troubleshooting sequence for three faults: intermittent ignition failure, delayed ignition, and sooting, listing the checks in order
Explain carbon monoxide testing procedure, acceptable readings, and the actions required when readings exceed limits
Your checkpoint
Completed commissioning and troubleshooting log for three simulated fault scenarios with the diagnostic path recorded
Gas fundamentals and properties of gases & Codes, regulations and standards & Installation of gas piping and tubing systems & Venting, combustion air and appliance installation & Testing, commissioning, servicing and troubleshooting
Review weak areas flagged by earlier deliverables and re-derive the underlying rule or calculation for each
Practice applying code clauses to short scenario questions under time pressure across all five domains
Recite the safety-critical limits from memory: leak test pressures, clearances, combustion air ratios, and CO thresholds
Plan the exam-day approach: question triage, unit-checking habit, and how to handle questions where two answers look plausible
Your checkpoint
Full-length timed practice exam with a written error analysis of every missed question
Milestones
Week 4: Score at least 80% on a 30-question mixed set covering Domains 1 and 2, and complete the pipe sizing worksheet with no arithmetic errors
Week 6: Score at least 80% on a 40-question set weighted to Domains 3 and 4, and correctly pass/fail both venting checklists with cited reasons
Week 8: Score at least 85% overall on the timed practice exam with no domain below 75%, and every missed question traced to a specific rule or calculation