- Milliampere-second (mAs)
- The product of tube current and exposure time. It determines the total number of x-ray photons produced and therefore beam quantity and receptor dose without substantially changing beam penetrability.
- Inverse square law
- X-ray intensity from a point source falls in proportion to the square of the distance. Doubling the distance from the source reduces intensity to one quarter of its original value.
- Grid ratio
- The height of the lead strips divided by the distance between them. Higher ratios remove more scattered radiation and improve contrast, but require greater mAs and increase patient dose.
- Photoelectric absorption
- An incident photon is completely absorbed and ejects an inner-shell electron. Probability rises steeply with atomic number, roughly as Z cubed, and falls with increasing photon energy.
- Compton scattering
- A photon transfers part of its energy to an outer-shell electron and is deflected. Probability depends mainly on electron density, changes little with atomic number, and dominates at higher diagnostic energies.
- Magnification
- The ratio of image size to object size, equal to source-to-image distance divided by source-to-object distance, where source-to-object distance is SID minus object-to-image distance.
- CT pitch
- Table travel per gantry rotation divided by total beam collimation. Pitch below one means overlapping slices and higher dose; pitch above one means gaps and lower dose.
- Window width and level
- Window level sets the CT number displayed as mid-grey, controlling brightness. Window width sets the range of CT numbers mapped to grey shades, controlling contrast and displayed latitude.
- Larmor equation
- Precessional frequency equals the gyromagnetic ratio multiplied by magnetic field strength. For hydrogen-1 the ratio is about 42.58 MHz per tesla, giving 63.9 MHz at 1.5 T.
- T1 relaxation time
- The time constant for recovery of longitudinal magnetization after a radiofrequency pulse, with about 63% recovered after one T1. T1 lengthens as field strength increases.
- T2 star decay
- Observed transverse decay that combines true T2 dephasing with additional dephasing from static field inhomogeneities. Gradient-echo sequences show T2 star contrast; spin echoes refocus the inhomogeneity component.
- Ernst angle
- The flip angle producing maximum signal for a given repetition time and tissue T1 in gradient-echo imaging. It becomes smaller as repetition time shortens.
- STIR fat suppression
- Short-tau inversion recovery applies an inversion pulse timed so fat magnetization passes through zero at excitation. It suppresses fat uniformly despite field inhomogeneity but lowers signal-to-noise ratio.
- Specific absorption rate
- Radiofrequency power deposited per unit mass, measured in watts per kilogram. It increases with field strength squared, flip angle, duty cycle and slice number, and is capped by safety standards.
- Gadolinium chelates
- Paramagnetic contrast agents that shorten T1 and T2 relaxation times, brightening tissue on T1-weighted images. They are avoided in severe renal impairment because of nephrogenic systemic fibrosis risk.
- K-space center
- The central lines of k-space encode image contrast and overall signal-to-noise, while the outer lines encode edges and fine detail. Centre-first filling produces high contrast early in the acquisition.
- Technetium-99m
- A generator-produced radionuclide with a 6.02-hour half-life and a 140 keV gamma emission, well matched to gamma camera imaging. It is the most widely used tracer in nuclear medicine.
- Effective half-life
- The combined result of physical decay and biological clearance, calculated as the reciprocal sum of the physical and biological half-lives. It determines how long activity remains in the patient.
- Positron annihilation
- A positron emitted by a proton-rich radionuclide travels a short distance, combines with an electron, and produces two 511 keV photons emitted about 180 degrees apart, detected in coincidence by PET.
- Photopeak energy window
- A pulse-height analyser setting that accepts events within a narrow range, typically plus or minus 10%, around the photopeak energy to include primary photons while rejecting scattered events.
- Random coincidence
- Two unrelated photons from separate annihilations detected within the coincidence timing window. The random rate rises with the square of activity and is reduced by shorter timing windows.
- Counting statistics
- Radioactive decay follows Poisson statistics, so the standard deviation of a count equals its square root. Relative uncertainty therefore falls as the total number of counts increases.
- Molybdenum-technetium generator
- A column containing molybdenum-99, half-life 66 hours, which decays to technetium-99m eluted with saline. Elution efficiency and molybdenum breakthrough are checked by routine quality control.
- Fluorodeoxyglucose
- A glucose analogue labelled with fluorine-18, half-life 110 minutes. It accumulates where glucose metabolism is increased, so fasting and glucose control before scanning are essential.
- Gray
- The SI unit of absorbed dose, equal to one joule per kilogram. One gray equals 100 rad, and a typical curative external beam course delivers 60 to 70 gray.
- Biologically effective dose
- Calculated as n times d times (1 plus d divided by alpha-beta), where n is fraction number and d is dose per fraction. It compares schedules differing in fraction size.
- Planning target volume
- A geometric volume adding set-up and organ-motion margins around the clinical target volume, ensuring the prescribed dose covers the target despite daily positioning uncertainty.
- Percentage depth dose
- The absorbed dose at a given depth expressed as a percentage of the maximum dose on the central axis. It increases with beam energy, field size and source-to-surface distance.
- Alpha-beta ratio
- A radiosensitivity parameter describing cell survival curve shape. Values near 10 gray indicate tumours and early-responding tissues; near 3 gray indicate late-responding tissues.
- Bolus
- Tissue-equivalent material placed on the skin surface to build up dose in superficial layers, bringing the maximum dose to the skin when treating lesions with megavoltage beams.
- Inverse planning
- An optimisation method used in IMRT where dose objectives and constraints are specified first, and the computer calculates the fluence maps instead of the planner shaping beams manually.
- Brachytherapy dose falloff
- Dose around an implanted source follows approximately the inverse square of distance, giving very high dose close to the source and rapid sparing a few centimetres away.