CCT (CCI) key terms
CCT · Get comfortable with the vocabulary.
- Standard Precautions
- Related: Electrode, Informed Consent
Infection-control steps used for every patient because any blood or body fluid may carry disease. They include hand hygiene and gloves, plus gown, mask, or eye protection when splashes are likely.
- Electrode
- Related: Somatic Tremor, Wandering Baseline
A small adhesive pad with conductive gel that sticks to the skin and detects the heart's electrical signal, passing it through a wire to the ECG machine or monitor.
- Informed Consent
- Related: Exercise Stress Test, Standard Precautions
Explaining a test's purpose, risks, benefits, and alternatives so the patient can decide freely whether to proceed. The patient must be alert enough to understand and ask questions.
- Precordial Lead Placement
- Related: Limb Lead Placement, Lead Reversal
Placing the six chest electrodes V1 to V6 at specific rib spaces and body landmarks so the tracings are consistent and can be compared between patients and over time.
- Limb Lead Placement
- Related: Precordial Lead Placement, Lead Reversal
Attaching electrodes to the right arm, left arm, right leg, and left leg at consistent spots such as wrists and ankles; these four electrodes create the six frontal-plane leads.
- Artifact
- Related: Somatic Tremor, Wandering Baseline
Any signal on the ECG that does not come from the heart, such as muscle movement, poor electrode contact, or nearby electrical devices. It can imitate or hide a real rhythm.
- Somatic Tremor
- Related: Artifact, Electrode
Jittery, high-frequency noise caused by shivering or muscle tension. It thickens the tracing and can hide small waves such as P waves or fibrillatory activity.
- Wandering Baseline
- Related: Artifact, Electrode
A slow, rolling drift of the baseline up and down, often from breathing, sweating, or loose electrodes. It makes measuring wave heights and ST segments unreliable.
- Calibration
- Related: Paper Speed, QRS Complex
Adjusting the ECG machine so that one millivolt of electrical signal produces a deflection ten millimeters tall. A square calibration mark at the start confirms the setting.
- Paper Speed
- Related: Calibration, PR Interval
How fast the ECG paper moves, usually 25 millimeters per second. At that speed one small box is 0.04 seconds and one large box is 0.20 seconds.
- P Wave
- Related: PR Interval, Sinus Rhythm
The first small deflection of a normal beat, caused by the atria depolarizing. It is normally upright in lead II and less than 0.12 seconds wide.
- PR Interval
- Related: P Wave, First-Degree AV Block
The time from the beginning of the P wave to the beginning of the QRS complex, normally 0.12 to 0.20 seconds. It shows how well the AV node conducts.
- QRS Complex
- Related: Bundle Branch Block, J Point
The tall, sharp deflection produced when the ventricles depolarize. A normal QRS is narrow, less than 0.12 seconds; a wider one suggests delayed ventricular conduction.
- QT Interval
- Related: T Wave, QRS Complex
The time from the start of the QRS to the end of the T wave, covering ventricular depolarization and repolarization. It shortens as heart rate rises and is often corrected for rate.
- ST Segment
- Related: J Point, T Wave
The section between the J point and the start of the T wave. It is normally flat; elevation or depression can mean acute injury or reduced blood flow to the heart muscle.
- J Point
- Related: ST Segment
The junction where the QRS complex ends and the ST segment begins. Technicians use it as the reference point for measuring ST elevation or depression.
- T Wave
- Related: QT Interval, ST Segment
The wave after the QRS that reflects the ventricles recovering electrically. It is usually upright in most leads and may flatten, invert, or peak with ischemia or electrolyte imbalance.
- Electrical Axis
- Related: Limb Lead Placement, QRS Complex
The main direction of ventricular depolarization as seen from the front of the body, estimated from the limb leads. A normal axis points down and toward the patient's left.
- Bundle Branch Block
- Related: QRS Complex, Electrical Axis
A delay or block in one of the two main bundles carrying the impulse to the ventricles. It widens the QRS to 0.12 seconds or more and often gives it a notched shape.
- Lead Reversal
- Related: Limb Lead Placement, Precordial Lead Placement
Swapping limb or chest electrodes by mistake, which makes the tracing look abnormal, such as an upside-down P wave in lead I. Spotting it prevents a healthy heart being called diseased.
- Sinus Rhythm
- Related: P Wave, PR Interval
The heart's normal rhythm, started by the sinoatrial node. It shows a consistent upright P wave in lead II before each QRS and a rate between 60 and 100 beats per minute.
- Premature Atrial Contraction
- Related: Premature Ventricular Contraction, Sinus Rhythm
An early beat that starts in the atria outside the sinus node. Its P wave often looks different from the normal one, and the following QRS is usually narrow.
- Premature Ventricular Contraction
- Related: Ventricular Tachycardia, Bundle Branch Block
An early beat that starts in the ventricles, so it has a wide, odd-looking QRS with no P wave before it. A pause usually follows before the next normal beat.
- Atrial Fibrillation
- Related: Atrial Flutter, Premature Atrial Contraction
A chaotic atrial rhythm with no true P waves, an irregularly irregular ventricular rate, and a wavy baseline. It raises stroke risk and often requires blood thinners.
- Atrial Flutter
- Related: Atrial Fibrillation
A fast, organized atrial rhythm that makes a regular sawtooth pattern instead of P waves, usually near 300 atrial beats per minute. The AV node lets only some impulses reach the ventricles.
- Ventricular Tachycardia
- Related: Ventricular Fibrillation, Premature Ventricular Contraction
A run of three or more ventricular beats faster than 100 per minute, producing wide QRS complexes. It can be brief or sustained and may worsen into a life-threatening rhythm.
- Ventricular Fibrillation
- Related: Ventricular Tachycardia
Disorganized electrical chaos in the ventricles with no usable QRS complexes and no effective pumping. It is a cardiac arrest rhythm that needs immediate CPR and defibrillation.
- First-Degree AV Block
- Related: PR Interval, Third-Degree AV Block
A consistent slowing of conduction through the AV node so the PR interval is longer than 0.20 seconds, while every P wave still produces a QRS complex.
- Third-Degree AV Block
- Related: First-Degree AV Block, Sinus Rhythm
Complete failure of impulses to pass from atria to ventricles, so P waves and QRS complexes occur independently at their own rates. The slow ventricular rate can cause dizziness or fainting.
- Holter Monitor
- Related: Event Monitor, Patient Diary
A portable recorder worn for 24 to 48 hours that continuously records the ECG while the patient does normal activities. It is used to catch intermittent arrhythmias or silent ischemia.
- Event Monitor
- Related: Holter Monitor, Patient Diary
A small recorder the patient turns on when symptoms occur, saving a short ECG strip. It is worn longer than a Holter and suits symptoms that happen only now and then.
- Implantable Loop Recorder
- Related: Event Monitor, Holter Monitor
A tiny device placed under the skin that watches the heart rhythm for months to years and saves abnormal events for the doctor to review later.
- Patient Diary
- Related: Holter Monitor, Event Monitor
A log in which the patient records the time of symptoms, activities, and medications during ambulatory monitoring, letting the reviewer match complaints to the recorded rhythm.
- Exercise Stress Test
- Related: Bruce Protocol, Target Heart Rate
An ECG recorded while the patient walks on a treadmill or pedals a bike against increasing resistance, looking for ischemia, arrhythmias, or abnormal blood pressure responses.
- Bruce Protocol
- Related: Exercise Stress Test, MET
A common treadmill protocol with stages of three minutes each in which speed and incline rise steadily, so most patients reach maximal effort within a predictable time.
- MET
- Related: Bruce Protocol
A unit for the energy cost of an activity compared with resting quietly, where 1 MET is the body's oxygen use at rest. Stress test workloads are often reported in METs.
- Target Heart Rate
- Related: Chronotropic Incompetence, Exercise Stress Test
The heart rate a patient should reach during a maximal test, often estimated as 85 percent of 220 minus age. Falling short may reflect poor effort, medications, or disease.
- Chronotropic Incompetence
- Related: Target Heart Rate
An abnormal failure of the heart rate to rise as expected during exercise, often defined as not reaching 85 percent of the age-predicted maximum despite real effort.