CCNP Data Center study materials
CCNP Data Center study resources

CCNP Data Center cheat sheet

CCNP Data Center · Keep the key ideas within reach.

Quick reference

Network

  • vPC peer-link must be a port channel with at least two member links; it carries CFSoE control traffic plus flooded data, and both peers must be configured with the same vPC domain ID.

  • vPC peer-keepalive runs out-of-band in the management VRF or a dedicated link on UDP 3200; if the peer-link fails, vPC member ports are suspended on the secondary peer.

  • vPC member ports must match on both peers: same port-channel ID, allowed VLAN list, MTU, speed and LACP mode; any mismatch keeps the port in a suspended state.

  • VXLAN adds 50 bytes of overhead (outer Ethernet 14 + outer IP 20 + UDP 8 + VXLAN 8) and uses UDP destination port 4789; underlay MTU must be raised to carry 1500-byte inner frames.

  • The VNI is 24 bits, giving usable values 1 through 16,777,214; each VTEP maps a local VLAN to a VNI and learns remote MAC-to-VTEP bindings.

  • BGP EVPN route types: type 2 = MAC/IP advertisement (host reachability, ARP/ND suppression), type 3 = inclusive multicast (BUM replication), type 5 = IP prefix (L3VNI).

  • Fabric Extender ports are not locally switched; a FEX forwards all host traffic to its parent, and a vPC FEX configuration requires the same FEX ID on both parent switches.

  • HSRPv2 uses multicast 224.0.0.102 and HSRPv1 uses 224.0.0.2, both over UDP 1985, with default hello 3 s and hold 10 s.

  • OTV transports Layer 2 frames between edge devices inside IP GRE tunnels and runs IS-IS as the overlay control plane over the same tunnel; the join interface sources the unicast replication.

Quick reference

Compute

  • UCS Manager runs on a pair of fabric interconnects in active/standby roles; both FIs must be the same model and are connected to each other as a cluster.

  • A service profile contains vNICs, vHBAs, boot policy, BIOS policy, firmware policy, scrubbing policy, and identity taken from MAC, WWN, UUID and IQN pools.

  • WWN pools are split into an A pool and a B pool; each vHBA draws its WWPN from the pool it was created with, so a profile keeps identity after a blade swap.

  • The UCS 5108 chassis holds eight half-width blades, two IOM slots, four power supplies and eight fan modules; IOMs uplink to the FIs over 10/40G fabric ports.

  • FI ports must be explicitly typed: server, uplink Ethernet, uplink Fibre Channel, FCoE uplink, FC storage, appliance, monitoring, or unconfigured.

  • Fabric failover on a vNIC moves traffic to the peer fabric interconnect when the primary path fails; enable it on vNICs that must survive an FI or uplink failure.

  • LAN pin groups and SAN pin groups restrict which uplinks a vNIC or vHBA may use; without a pin group the FI selects uplinks from the VLAN or VSAN membership.

  • Infrastructure firmware (FI, IOM, adapter) is updated per UCS domain, while host firmware packages are applied through the host firmware policy referenced by the service profile.

  • Once ports are configured as server ports, the FI automatically discovers chassis IOMs and adapters; no manual per-blade configuration is required.

Quick reference

Storage Network

  • FC port types: N (host), F (fabric-facing to host), FL (fabric loop), E (ISL), TE (trunking ISL), NP (NPV uplink), TF (NPV host port), SD (SPAN destination).

  • The FC ID is 24 bits: 8-bit domain ID, 8-bit area, 8-bit port; domain IDs range 1-239 and must be unique within the fabric.

  • FLOGI assigns the 24-bit FC ID to an N port; FDISC registers additional FC IDs for NPV/NPIV without performing a new fabric login.

  • NPIV lets a single F port register up to 255 FC IDs; an NPV switch takes no domain ID and runs no fabric services, proxying logins to the core switch.

  • A VSAN is an independent fabric instance; an interface joins with 'switchport mode F' plus 'switchport trunk allowed vsan X' or VSAN database membership.

  • Zone sets must be activated ('zoneset activate name X vsan Y') before they take effect; hard zoning enforces access by FC ID in hardware, soft zoning filters in the name server.

  • Default zone policy 'permit' allows unzoned devices to communicate; configure 'no zone default-zone permit vsan X' to block them.

  • FCoE data frames use Ethertype 0x8906 and FIP uses 0x8914; the FCoE MAC is FC-MAP (default 0x0EFC00) plus the 24-bit FC ID, and PFC/ETS must be enabled for lossless service.

  • SAN port channels are built from E or TE ports; TE (trunking) ISLs carry multiple VSANs, while E ports carry a single VSAN.

Quick reference

Automation

  • NX-API is enabled with 'feature nxapi' and listens on HTTP 80 and HTTPS 443; the ins_api payload supports cli_show, cli_conf and cli_ascii message types with JSON or XML output.

  • NX-API accepts multiple commands in one request, and setting chunk to '1' splits large responses into smaller messages.

  • POAP: a switch with an empty startup configuration boots, receives an address and script location by DHCP, then downloads and applies image and configuration from TFTP or HTTP.

  • APIC REST base path is https:///api/; authenticate with aaaLogin to obtain a token carried in the APIC-Cookie, then address objects by distinguished names such as uni/tn-TENANT/ap-APP/epg-EPG.

  • Ansible nxos_command, nxos_config and nxos_facts use the httpapi connection plugin for NX-API or the network_cli plugin for SSH.

  • Model-driven telemetry subscriptions define YANG sensor paths, encoding (GPB or JSON) and sample interval; data is streamed to a collector over gRPC in a dial-out model.

  • NETCONF runs over SSH on port 830; the Python library ncclient issues RPCs such as get-config and edit-config against YANG models.

  • DCNM exposes REST endpoints under /rest/ for fabric discovery, configuration deployment and image management, returning JSON or XML responses.

Quick reference

Security

  • TACACS+ uses TCP 49, encrypts the full packet body, and supports per-command authorization through AV pairs; RADIUS uses UDP 1812/1813 and encrypts only the password.

  • NX-OS AAA order: define 'aaa group server', add 'server ', then apply 'aaa authentication login default group X'; the local database is used only if configured as fallback.

  • Built-in NX-OS roles are network-admin, network-operator, vdc-admin, vdc-operator and san-admin; custom roles combine read or read-write rules per feature.

  • Port security limits learned MAC addresses per interface; violation modes are protect (drop), restrict (drop plus log/SNMP) and shutdown (err-disable the port).

  • DHCP snooping builds the binding table of MAC, IP, VLAN and port; Dynamic ARP Inspection validates ARP against it, and IP Source Guard uses it to filter traffic.

  • CoPP attaches a policy-map to the control plane, classifying and rate-limiting traffic punted to the supervisor so a flood cannot exhaust CPU resources.

  • MACsec (IEEE 802.1AE) encrypts each link hop at line rate; MACsec Key Agreement derives session keys from a pre-shared connectivity association key.

  • In ACI, EPGs exchange traffic only through contracts whose filters permit specific protocols and ports; shared objects such as filters can live in the common tenant.