CCNP Data Center flashcards
CCNP Data Center · Build recall with a focused review session.
32 cards. Read the term and the definition here. The deck at the top of this page is optional.
- vPC peer-keepalive
- Out-of-band heartbeat between vPC peers sent over the management VRF or a dedicated link on UDP 3200; it detects peer liveness when the peer-link fails.
- vPC peer-link
- 802.1Q trunk port channel between two vPC peers that carries CFSoE control traffic and flooded data; it needs at least two member links with matching allowed VLANs.
- vPC orphan port
- A port that is not part of any vPC and connects a single-homed device; it stays forwarding during a peer-link failure, so orphan ports on both peers must not reach the same Layer 2 domain.
- VXLAN VNI
- 24-bit segment identifier with roughly 16.7 million usable values; it is carried in the 8-byte VXLAN header and mapped to a VLAN on the local VTEP.
- VTEP
- VXLAN tunnel endpoint that encapsulates and decapsulates Layer 2 frames into UDP destination port 4789; each VTEP maps local VLANs to VNIs and learns remote MAC addresses.
- EVPN route type 2
- BGP EVPN MAC/IP advertisement route that distributes host MAC and IP bindings between VTEPs, enabling ARP and ND suppression along with symmetric IRB forwarding.
- Fabric Extender (FEX)
- Nexus 2000-series device that extends parent switch ports to the top of rack; it performs no local switching and forwards all host traffic to the parent over fabric ports.
- Service profile
- XML object in UCS Manager that defines server identity and connectivity: vNICs, vHBAs, boot and BIOS policies, firmware policy, and pool-derived MAC, WWN and UUID values.
- UCS MAC pool
- A named range of MAC addresses from which service profiles assign addresses to vNICs, so a server keeps the same identity when moved to another blade.
- Fabric interconnect cluster
- Two UCS fabric interconnects of the same model managed by a single UCS Manager in active/standby mode; they interconnect and present one unified management domain.
- Fabric failover
- vNIC setting that sends traffic through the peer fabric interconnect when the primary path fails, keeping the server reachable without re-cabling.
- UCS 5108 chassis
- Blade chassis with eight half-width blade slots, two IOM slots, four power supplies and eight fans; IOMs uplink to the fabric interconnects over 10/40G links.
- Boot policy
- Ordered list of boot targets in a UCS service profile, such as local disk, SAN LUN, LAN PXE or virtual media, used when the server starts up.
- FC ID format
- 24-bit address made of an 8-bit domain, 8-bit area and 8-bit port field; the domain identifies the switch and must be unique within the fabric.
- FLOGI
- Fabric login process in which an N port sends a FLOGI to the attached F port and receives a 24-bit FC ID plus a buffer-to-buffer credit allocation.
- NPIV
- N port ID virtualization lets one physical F port register multiple FC IDs, up to 255 per port on Cisco switches, giving each virtual machine its own WWPN.
- NPV mode
- N port virtualization: the switch acts as an NPIV proxy with F ports toward hosts and NP uplinks to the core, taking no domain ID and running no fabric services.
- VSAN
- Logically isolated Fibre Channel fabric inside a physical switch; name server, zoning and domain ID are per-VSAN, and each interface belongs to one VSAN.
- Hard zoning
- Zoning enforced in switch hardware through FC ID based access control, so frames are dropped even when a device bypasses the name server.
- FCoE Ethertype
- FCoE data frames use Ethertype 0x8906 and FIP frames use 0x8914; both require a lossless Ethernet class with PFC and ETS configured end to end.
- NX-API
- HTTP/HTTPS interface on Nexus switches enabled with the feature nxapi command that accepts JSON or XML requests and returns structured command output on ports 80 and 443.
- POAP
- PowerOn Auto Provisioning: a switch with no startup configuration gets an address by DHCP, downloads a script and image, and applies configuration automatically.
- APIC REST API
- HTTPS JSON interface to the Cisco APIC; clients authenticate with aaaLogin to obtain a token, then address objects by distinguished names such as uni/tn-tenant.
- nxos_config module
- Ansible module that pushes configuration lines or full configuration files to Nexus devices idempotently, using the network_cli or httpapi connection plugin.
- gRPC telemetry
- Model-driven streaming telemetry in which the switch pushes data for subscribed YANG sensor paths to a collector over gRPC, encoded as GPB or JSON.
- DCNM REST API
- Cisco Data Center Network Manager REST endpoints for fabric discovery, configuration deployment and image management; responses are returned in JSON or XML.
- TACACS+
- AAA protocol over TCP 49 that encrypts the entire packet body and separates authentication, authorization and accounting, supporting per-command authorization with AV pairs.
- RADIUS
- AAA protocol using UDP 1812 and 1813 that encrypts only the password inside the access request and provides no per-command authorization.
- DHCP snooping
- Feature that marks ports trusted or untrusted and builds a binding table of MAC, IP, VLAN and port; untrusted ports cannot offer DHCP addresses.
- Dynamic ARP Inspection
- Validates ARP packets against the DHCP snooping binding table and drops mismatches received on untrusted ports, blocking ARP spoofing inside the VLAN.
- CoPP
- Control Plane Policing: a policy-map attached to the control plane that classifies and rate-limits traffic punted to the supervisor, protecting the CPU from floods.
- MACsec
- IEEE 802.1AE encryption applied per hop at line rate; MACsec Key Agreement negotiates session keys from a pre-shared connectivity association key.