CDA study materials
CDA study resources

CDA cheat sheet

CDA · Keep the key ideas within reach.

Quick reference

General Chairside Assisting (GC)

  • Universal numbering: permanent teeth 1–32 beginning with the maxillary right third molar; primary teeth A–T beginning with the maxillary right second primary molar.

  • FDI two-digit system: first digit is the quadrant (1–4 permanent, 5–8 primary), second digit is tooth position from the midline (1–8).

  • Arch quadrants in Universal numbering: maxillary right 1–8, maxillary left 9–16, mandibular left 17–24, mandibular right 25–32.

  • Modified pen grasp: instrument rests on the pads of the thumb, index, and middle fingers, with the ring finger serving as the fulcrum rest.

  • Inferior alveolar block landmarks: coronoid notch, pterygomandibular raphe, and the occlusal plane of the mandibular molars as the height guide.

  • Normal adult vital signs: blood pressure under 120/80 mmHg, pulse 60–100 bpm, respirations 12–20 per minute, oral temperature about 98.6°F (37°C).

  • Zinc phosphate cement sets by an exothermic acid-base reaction, so it is mixed on a cool, thick glass slab with powder added in small increments.

  • Class II matrix assembly: the band re-establishes proximal contour while the wedge adapts the band to the gingival margin and slightly separates the teeth.

  • Sutures placed in oral mucosa are typically removed 5–7 days after placement.

Quick reference

Radiation Health and Safety (RHS)

  • Inverse square law: beam intensity is proportional to 1/d², so doubling the distance from the source reduces exposure to one quarter.

  • NCRP occupational limits: 50 mSv (5 rem) effective dose per year, 150 mSv to the lens of the eye, 500 mSv to extremities and skin.

  • A round collimator must restrict the beam to 2.75 inches (7 cm) at the end of the PID; rectangular collimation reduces the exposed area and dose further.

  • A 16-inch PID increases target-to-skin distance and reduces beam divergence, lowering skin exposure compared with an 8-inch PID.

  • kVp governs beam penetration and subject contrast (higher kVp = lower contrast, wider latitude); mA governs x-ray quantity; exposure time governs duration.

  • SLOB rule for horizontal tube shifts: an object moving in the same direction as the tube head is lingual; an object moving opposite is buccal.

  • Minimum lead apron equivalence is 0.25 mm Pb; a thyroid collar is used for all patients, especially children and pregnant patients.

  • An operator without a barrier stands at least 6 feet from the tube head, at 90–135 degrees to the primary beam.

  • Personnel dosimeter badges are worn at collar level outside the lead apron and are processed monthly or quarterly.

Quick reference

Infection Control (ICE)

  • Chain of infection: infectious agent, reservoir, portal of exit, mode of transmission, portal of entry, susceptible host; breaking any single link interrupts transmission.

  • Spaulding classification: critical items (bone or soft-tissue contact) must be sterile; semicritical items (intact mucosa) need high-level disinfection at minimum; noncritical items (intact skin) need low-level disinfection.

  • Standard steam autoclave cycle: 121°C (250°F) at 15 psi for 15–20 minutes; flash cycle 132°C (270°F) for 3–4 minutes for unwrapped items.

  • Biologic monitoring organisms: Geobacillus stearothermophilus spores for steam sterilizers; Bacillus atrophaeus spores for dry heat and ethylene oxide sterilizers.

  • Hand hygiene: soap-and-water wash for at least 20 seconds; alcohol-based rub when hands are not visibly soiled.

  • PPE removal order: gloves first, then eyewear or face shield, then gown, then mask last; gloves are removed without contacting their outer surface.

  • Heavy utility gloves, not treatment gloves, are worn for instrument cleaning, disinfection, and chemical handling.

  • Dental unit waterlines are flushed 20–30 seconds between patients and for 2 minutes at the start of each day, with an EPA-registered treatment product.

  • Sharps containers are replaced when three-quarters full, and needles are never recapped with two hands; a one-handed scoop technique is used.