CDA flashcards
CDA · Build recall with a focused review session.
32 cards. Read the term and the definition here. The deck at the top of this page is optional.
- Universal tooth numbering
- Permanent teeth are numbered 1 through 32, starting with the maxillary right third molar as tooth 1 and ending with the mandibular right third molar as tooth 32.
- Primary tooth lettering
- Primary teeth use letters A through T. A is the maxillary right second primary molar, and the series continues around the arch to T, the mandibular right second primary molar.
- FDI two-digit system
- The first digit identifies the quadrant (1–4 for permanent, 5–8 for primary) and the second digit identifies the tooth position from the midline (1–8).
- Modified pen grasp
- The instrument is held on the pads of the thumb, index, and middle fingers, while the ring finger rests on a stable oral structure as a fulcrum for control.
- High-volume evacuator placement
- The HVE tip is placed at the occlusal surface of the tooth being treated, about one-quarter inch from the operating site, to capture spray and aerosols.
- Inferior alveolar block landmarks
- Key landmarks are the coronoid notch, the pterygomandibular raphe, and the occlusal plane of the mandibular molars, which sets the height of needle insertion.
- Retraction cord function
- Cord is packed into the gingival sulcus to displace tissue and expose the finish line; medicated cords also control hemorrhage and shrink tissue before impression taking.
- Zinc phosphate cement mixing
- Powder is incorporated into liquid in small increments on a cool, thick glass slab; the reaction is exothermic, and a thin mix is used to cement cast restorations.
- Matrix band and wedge
- The band re-establishes proximal contour in a Class II preparation, and the wedge holds the band tightly against the tooth while slightly separating adjacent teeth.
- Normal adult vital signs
- Typical adult values are blood pressure under 120/80 mmHg, pulse 60–100 beats per minute, respirations 12–20 per minute, and oral temperature near 98.6°F (37°C).
- Suture removal timeline
- Sutures in oral mucosa are generally removed 5 to 7 days after placement, once the tissue has regained enough strength to hold the wound edges together.
- Inverse square law
- X-ray intensity is inversely proportional to the square of the distance from the source, so doubling the distance reduces exposure to one quarter of its original value.
- Occupational dose limits
- NCRP limits are 50 mSv (5 rem) whole-body effective dose per year, 150 mSv to the lens of the eye, and 500 mSv to the extremities and skin.
- Beam collimation standard
- A round collimator must restrict the beam to 2.75 inches (7 cm) at the end of the position-indicating device; rectangular collimation exposes a smaller area and lowers dose.
- Long PID benefit
- A 16-inch position-indicating device increases target-to-skin distance and reduces beam divergence, lowering skin exposure compared with an 8-inch PID.
- kVp and image contrast
- kVp determines beam penetration and subject contrast. Higher kVp produces lower contrast with more gray shades and wider latitude; lower kVp produces higher contrast.
- SLOB rule
- For horizontal angulation shifts, the object that moves in the same direction as the tube head is lingual; the object moving opposite is buccal.
- Lead apron equivalence
- A lead apron must equal at least 0.25 mm of lead; a thyroid collar is added for all patients, especially children and pregnant patients.
- Operator position without barrier
- Stand at least 6 feet from the tube head at an angle of 90 to 135 degrees to the primary beam, out of the path of the useful beam and scatter.
- Dosimeter badge placement
- The monitoring badge is worn at collar level outside the lead apron so it records head and neck dose, and it is processed monthly or quarterly.
- F-speed film dose
- F-speed intraoral film is the fastest film available and requires roughly half the exposure of D-speed film, cutting patient dose by about 50 to 60 percent.
- Bisecting angle principle
- The central ray is directed perpendicular to the imaginary bisector of the angle formed by the film and the long axis of the tooth, preventing elongation or foreshortening.
- Chain of infection
- Six links are required for transmission: infectious agent, reservoir, portal of exit, mode of transmission, portal of entry, and susceptible host; breaking any link stops infection.
- Critical items
- Items that contact bone or penetrate soft tissue, such as surgical instruments, scalers, and extraction forceps, are critical and must be sterilized after every use.
- Semicritical items
- Items contacting intact mucous membranes, such as mouth mirrors and impression trays, are semicritical and require at least high-level disinfection, with sterilization preferred.
- Steam autoclave cycle
- The standard gravity cycle is 121°C (250°F) at 15 psi for 15 to 20 minutes; the flash cycle is 132°C (270°F) for 3 to 4 minutes on unwrapped items.
- Spore test organism
- Geobacillus stearothermophilus spores biologically monitor steam sterilizers, while Bacillus atrophaeus spores are used for dry heat and ethylene oxide sterilizers.
- Spore testing frequency
- Biological monitoring is performed at least weekly for each sterilizer, and every load containing implantable items should be monitored as well.
- Hand hygiene duration
- Hands are washed with soap and water for at least 20 seconds, or an alcohol-based hand rub is used when the hands are not visibly soiled.
- PPE removal order
- Gloves are removed first, then eyewear or face shield, then the gown, and the mask last; gloves are taken off without touching their outer surface.
- Dental unit waterline flushing
- Waterlines are flushed for 20 to 30 seconds between patients and for 2 minutes at the start of the day to reduce discharge of microbial biofilm.
- Sharps container fill limit
- Sharps containers are replaced when they are three-quarters full, and needles are never recapped with two hands; a one-handed scoop technique is used instead.