CFPS key terms
CFPS · Get comfortable with the vocabulary.
- Flashover
- Related: Heat Release Rate, Pyrolysis
The sudden transition in a compartment fire when exposed combustible surfaces ignite almost simultaneously because radiant heat from the hot upper gas layer has driven them to ignition temperature. It marks the change from a growth-limited fire to a fully developed, ventilation-controlled fire.
- Backdraft
- Related: Flammability Limits, Flashover
A rapid deflagration that occurs when air enters a hot, fuel-rich, oxygen-starved compartment and mixes with accumulated unburned gases that then ignite, often forcing flame out of the opening with explosive force.
- Fire Tetrahedron
- Related: Pyrolysis, Clean Agent
A model of combustion requiring four elements: fuel, oxidizer, heat, and an uninhibited chemical chain reaction. Removing any one element stops burning, and extinguishing agents work by interrupting at least one of them.
- Pyrolysis
- Related: Fire Tetrahedron, Flashover
The thermal decomposition of a solid fuel into combustible gases and vapors before flaming combustion begins. It is an endothermic, temperature-driven chemical change, which is why solid fuels actually burn as gases.
- Heat Release Rate
- Related: Flashover, Design Fire
The rate at which a fire liberates chemical energy, usually reported in kilowatts or Btu per second as it changes over time. It drives fire growth, detector response, and sprinkler activation.
- Flammability Limits
- Related: Flash Point, Backdraft
The range of fuel concentration in air, expressed in volume percent, within which a gas or vapor will ignite. Below the lower limit the mixture is too lean; above the upper limit it is too rich.
- Design Fire
- Related: Heat Release Rate, Performance-Based Design
A hypothetical fire, described by its growth rate, peak heat release rate, and duration, that an engineer selects to test whether a proposed design meets its stated performance criteria.
- Authority Having Jurisdiction
- Related: Model Code, Listing
The organization or individual with legal authority to enforce a code and approve equipment, plans, and installations, such as a fire marshal or building official. It also settles questions of code interpretation.
- Model Code
- Related: Authority Having Jurisdiction, Referenced Standard
A consensus document written by a standards organization for possible adoption by a government. Until a jurisdiction formally adopts it, a model code has no legal force.
- Referenced Standard
- Related: Model Code, Listing
A document cited by number and edition inside a code, making its provisions enforceable as part of that code. Compliance therefore depends on using the specific edition that was referenced.
- Listing
- Related: Authority Having Jurisdiction, Referenced Standard
Certification by a recognized testing laboratory that a product complies with a published standard and performs as described. Listed products bear a registered mark and are usually required for fire protection equipment.
- Occupancy Classification
- Related: Occupant Load, Means of Egress
Grouping of a building or space by its use and the hazard that use creates, such as assembly, business, or storage. The classification sets limits on height, construction type, and required egress features.
- Performance-Based Design
- Related: Design Fire, Model Code
A design approach accepted on demonstrated ability to meet stated safety goals through engineering analysis of fire scenarios, rather than on strict compliance with fixed prescriptive rules.
- Initiating Device Circuit
- Related: Notification Appliance Circuit, Addressable System
The wiring pathway linking automatic detectors and manual pull stations to the fire alarm control unit. An open or short circuit on it normally produces a trouble indication at the panel.
- Notification Appliance Circuit
- Related: Initiating Device Circuit, Addressable System
The circuit that supplies operating power to audible and visible signaling appliances such as horns, speakers, and strobes. Its voltage drop and current must be calculated to ensure adequate output at the farthest device.
- Addressable System
- Related: Initiating Device Circuit, Supervisory Signal
A fire alarm system in which each initiating device and appliance carries a unique address, letting the control unit report the specific device in alarm or trouble rather than only a circuit.
- Supervisory Signal
- Related: Addressable System, Initiating Device Circuit
An indication that a system component is off-normal without being in alarm, such as a closed sprinkler control valve, low dry-pipe air pressure, or a fire pump left in manual mode.
- Design Density
- Related: Design Area, Sprinkler K-Factor
The amount of water a sprinkler system must discharge over the design area, stated in gallons per minute per square foot. It is chosen from hazard-based tables and paired with an assumed operating area.
- Sprinkler K-Factor
- Related: Design Density, Residual Pressure
A coefficient describing a sprinkler's discharge, equal to flow in gallons per minute divided by the square root of pressure in psi. A larger K-value delivers more water at a given pressure.
- Design Area
- Related: Design Density, Quick-Response Sprinkler
The hydraulically most remote area of sprinkler coverage assumed to be flowing at once in a calculation, measured in square feet. Its size varies with hazard and may be reduced for quick-response sprinklers.
- Quick-Response Sprinkler
- Related: Design Area, Heat Release Rate
A sprinkler with a fast-acting thermal element that operates earlier in a growing fire than standard-response types, improving life safety and often allowing a smaller design area or reduced clearances.
- Deluge System
- Related: Design Density
A system with open sprinklers connected to a valve that opens on detection, discharging water from all heads simultaneously. It suits high-hazard occupancies needing rapid application over a large area.
- Clean Agent
- Related: Fire Tetrahedron
A gaseous extinguishing medium that leaves no residue, does not conduct electricity, and is safe for occupied spaces at design concentration. Halocarbon and inert gas agents work by cooling and interrupting the combustion chemistry.
- Wet Chemical Agent
- Related: Fire Tetrahedron
An alkaline solution, usually potassium-based, that reacts with hot cooking oil to form a smothering foam and also cools the fuel. It is the standard agent for Class K cooking equipment fires.
- Occupant Load
- Related: Means of Egress, Travel Distance
The number of people a space is designed to hold, computed from floor area and use or counted from fixed seating. It determines required egress width, number of exits, and exit capacity.
- Means of Egress
- Related: Occupant Load, Travel Distance
The continuous, unobstructed path from any point in a building to the public way, made up of exit access, the exit itself, and exit discharge.
- Common Path of Egress Travel
- Related: Travel Distance, Means of Egress
The part of travel from a point in a space until two separate routes to exits become available. Codes limit its length because occupants have only one direction of escape during that segment.
- Travel Distance
- Related: Common Path of Egress Travel, Means of Egress
The length measured along the natural path from the most remote point of a space to the nearest exit, limited by code according to occupancy and the presence of sprinkler protection.
- Horizontal Exit
- Related: Areas of Refuge, Travel Distance
A passage through a fire-rated wall with self-closing doors into an adjoining area or building that serves as a safe refuge, letting occupants leave the fire area without using stairs.
- Areas of Refuge
- Related: Horizontal Exit, Defend-in-Place
A protected space, such as a stair landing or rated room, where people unable to use stairs can wait for assistance. It must resist fire and smoke and connect to an accessible route.
- Defend-in-Place
- Related: Areas of Refuge, Horizontal Exit
A strategy in which occupants of a facility, typically a hospital or high-rise, stay inside protected compartments while staff control the fire, instead of evacuating the whole building.
- Fire Flow
- Related: Residual Pressure, Hazen-Williams Formula
The water rate in gallons per minute needed to control a fire in a given building, estimated from construction, occupancy, and exposure. It is compared against the supply available from mains and hydrants.
- Hazen-Williams Formula
- Related: Fire Flow, Residual Pressure
An empirical equation that predicts friction loss in a water-filled pipe from flow rate, pipe diameter, length, and a roughness coefficient. It is the workhorse of sprinkler and water main hydraulic calculations.
- Residual Pressure
- Related: Fire Flow, Fire Pump Rated Capacity
The pressure remaining at a point in a distribution system while water is flowing, typically measured at a hydrant during a flow test. Comparing it with static pressure shows how much supply is available.
- Fire Pump Rated Capacity
- Related: Residual Pressure, Fire Flow
The flow in gallons per minute at which a fire pump delivers its rated pressure at rated speed. Performance must also be verified at churn and at 150 percent of rated flow.
- Flash Point
- Related: Flammability Limits, NFPA 704 Hazard Marking
The lowest temperature at which a liquid produces enough vapor to form an ignitable mixture just above its surface, measured by a standard open-cup or closed-cup test. It drives flammable liquid classification.
- Boiling Liquid Expanding Vapor Explosion
- Related: Flash Point, NFPA 704 Hazard Marking
A tank failure that occurs when a pressure vessel holding liquid above its atmospheric boiling point ruptures, releasing expanding vapor that can ignite into a fireball and throw vessel fragments.
- NFPA 704 Hazard Marking
- Related: Flash Point, Flammability Limits
A placard using a diamond with four color-coded fields for health, flammability, instability, and special hazards, each scored zero to four, warning responders about materials stored at a site.
- Dust Explosion
- Related: Flammability Limits, NFPA 704 Hazard Marking
Rapid combustion of finely divided combustible particles suspended in air inside an enclosure, producing pressure that can rupture structures and dislodge more dust, causing secondary explosions.
- Risk Assessment
- Related: Performance-Based Design
A structured process of identifying hazards, estimating how likely and how severe harm could be, and judging whether existing controls reduce risk enough to be acceptable.