Auditing Fundamentals, Principles, and Types of Audits

  • ISO 19011 definition: an audit is a systematic, independent and documented process for obtaining objective evidence and evaluating it objectively against audit criteria to determine the extent of conformity.

  • First-party audit = internal audit performed by (or on behalf of) the organization itself; second-party = performed by a party with an interest, such as a customer or supplier; third-party = performed by an independent certification/registration body.

  • ISO 19011 principles: integrity, fair presentation, due professional care, confidentiality, independence, an evidence-based approach, and a risk-based approach.

  • Independence rule: auditors must not audit their own work; an auditor cannot audit an activity for which they have direct responsibility or a conflict of interest.

  • Audit categories: system audit (whole QMS), process audit (one process end-to-end), product/service audit (conformity of output), and compliance/surveillance audits.

  • Audits are sampling exercises; conclusions are based on samples and therefore carry sampling risk - an audit provides reasonable, not absolute, assurance of conformity.

  • Logical chain: audit criteria + objective evidence -> audit findings -> audit conclusions -> audit report.

  • Conformance-based vs performance-based auditing: the first checks against written requirements, the second measures how well a process actually achieves its intended results.

Quick reference

Medical Device Regulatory and Quality System Requirements

  • ISO 13485:2016 structure: Clause 4 Quality management system, Clause 5 Management responsibility, Clause 6 Resource management, Clause 7 Product realization, Clause 8 Measurement, analysis and improvement.

  • 21 CFR Part 820 subparts: A General provisions, B Quality system requirements, C Design controls, D Document controls, E Purchasing controls, F Identification and traceability, G Production and process controls, H Acceptance activities, I Nonconforming product, J CAPA, K Labeling and packaging, L Handling/storage/distribution, M Records, N Servicing, O Statistical techniques.

  • 21 CFR 820.180(b) record retention: records kept for the design and expected life of the device, but never less than 2 years from the date of release for commercial distribution.

  • EU MDR 2017/745 replaced MDD 93/42/EEC and became applicable 26 May 2021; device classification (I, IIa, IIb, III) follows Annex VIII rules and drives conformity-assessment route.

  • MDSAP combines audits for five jurisdictions: US FDA, Health Canada, Australia's TGA, Brazil's ANVISA, and Japan's MHLW/PMDA.

  • ISO 13485 requires a risk-based approach throughout the QMS and mandates validation of software used in the quality management system; it does not itself prescribe a full ISO 14971 risk management process.

  • ISO 13485 excludes certain ISO 9001 requirements not appropriate for regulatory purposes (e.g., customer satisfaction as a QMS output) and emphasizes meeting applicable regulatory requirements.

  • Traceability: 21 CFR 820.65 requires traceability of implants and life-supporting/life-sustaining devices; ISO 13485 Clause 7.5.9 extends this to defined records and distribution records.

  • UDI and labeling controls tie device identification to records; labeling must be checked for accuracy before release (21 CFR 820.120, 820.130).

Quick reference

Risk Management, Design Controls, and Process Validation

  • ISO 14971:2019 defines risk as the combination of the probability of occurrence of harm and the severity of that harm; risk is evaluated against pre-defined acceptability criteria from the risk management plan.

  • Risk management sequence: risk management planning -> hazard/hazardous situation identification -> risk estimation -> risk evaluation -> risk control -> evaluation of overall residual risk -> risk management review/report -> production and post-production monitoring.

  • Risk control option hierarchy in order of preference: (1) inherent safety by design, (2) protective measures in the device or manufacturing process, (3) information for safety (labeling, training).

  • Design controls (21 CFR 820.30) apply to Class II and III devices and certain Class I devices; required elements: planning, design input, design output, design review, verification, validation, transfer, design changes, and the Design History File.

  • Verification answers 'did we build the product right' (outputs meet inputs); validation answers 'did we build the right product' (device meets user needs and intended use under actual or simulated use conditions).

  • Process validation establishes objective evidence that a process consistently produces a result meeting predetermined specifications; typical stages are Installation Qualification (IQ), Operational Qualification (OQ), and Performance Qualification (PQ).

  • 21 CFR 820.75 requires validation of processes where results cannot be fully verified by subsequent inspection and test, plus defined revalidation criteria and validated software used in the process.

  • Special processes (e.g., sterilization, welding, soldering) require validation per ISO 13485 Clause 7.5.6; personnel competence must be qualified for such processes.

  • Risk management continues after release: complaints, CAPA, and adverse event data feed back into hazard analysis and residual-risk evaluation.

Quick reference

Audit Program Management and Auditor Competence/Ethics

  • Audit program management follows PDCA: establish program objectives -> plan the program -> implement audits -> monitor and review program performance -> improve.

  • Audit program objectives must be risk-based and linked to the organization's strategic direction, compliance obligations, and prior audit performance.

  • Auditor competence = knowledge and skills (audit principles, standards and criteria, organization and processes, products/services, applicable law) + education + work experience + audit training + personal attributes.

  • Personal attributes expected of auditors per ISO 19011: ethical, open-minded, diplomatic, observant, perceptive, versatile, tenacious, decisive, self-reliant, and able to act with integrity.

  • Audit team leader duties: prepare the audit plan, assign tasks to team members, manage the opening and closing meetings, resolve conflicts, and approve the audit report.

  • Ethics rules: no gifts or hospitality that could influence judgment, protect confidentiality of information obtained during the audit, disclose conflicts of interest, and report findings truthfully without bias.

  • Auditor performance is evaluated through observation, review of audit reports and records, feedback from auditees, and periodic re-evaluation of competence.

  • Audit program records include audit plans, reports, nonconformity records, corrective action follow-up, and auditor qualification records.

Quick reference

Audit Planning and Preparation

  • Three anchor questions: scope = what is being audited (units, processes, locations); criteria = the requirements used as a reference (ISO 13485, 21 CFR 820, procedures); objectives = why the audit is being done.

  • Audit plan contents per ISO 19011: objectives, scope, criteria, dates and duration, locations, audit team and roles, resources, confidentiality arrangements, and follow-up actions.

  • The audit plan should be communicated to the auditee in advance and may be revised as the audit progresses when the evidence warrants it.

  • The checklist is an aide-memoire, not a script; relevant documents should be reviewed before the audit to target the checklist at high-risk processes.

  • Sampling methods: judgmental (based on risk, complexity, prior history) and statistical (random/systematic, e.g., ANSI/ASQ Z1.4 attribute sampling tables).

  • Sample size should increase with process complexity, number of personnel, volume of records, and prior nonconformity history.

  • Preparation includes reviewing prior audit findings and CAPA status, regulatory commitments, complaint trends, and any changes since the last audit.

  • The opening meeting covers: purpose and scope, criteria, schedule, team introductions, audit methods and sampling, confidentiality, safety/access rules, and how findings will be communicated.

Quick reference

Audit Execution, Interviewing, and Objective Evidence Gathering

  • Objective evidence is verifiable information, records, or statements of fact; it must be traceable to a document, record, observation, or person, and independently confirmable.

  • Evidence hierarchy: physical observation and records outweigh unverified verbal statements; hearsay and opinion are not objective evidence.

  • Open-ended questions (what, why, when, where, who, how) elicit detail; leading or closed yes/no questions and questions suggesting the answer should be avoided.

  • Interview technique: start with a clear purpose, ask one question at a time, listen without interrupting, verify understanding by summarizing, and avoid interrogating the person.

  • Vertical (trail) auditing follows one record or product through every process step and department; horizontal auditing samples the same practice across multiple areas for consistency.

  • Field notes should record who, what, where, when, document identifiers, and equipment IDs so the finding can be reconstructed and reconfirmed later.

  • Distinguish observation from inference: an auditor records what is seen and documented, not conclusions drawn without supporting evidence.

  • Closing meeting purpose: present findings and conclusions in order of significance, confirm factual accuracy with the auditee, and agree on response timing and follow-up.

Quick reference

Findings Classification, Reporting, and CAPA Follow-Up

  • Finding categories: conforming finding, observation/opportunity for improvement (no requirement violated), and nonconformity (a requirement was not met).

  • Major nonconformity indicators: absence of a required element of the QMS, a systemic breakdown affecting multiple areas, or a condition likely to cause product or patient safety risk.

  • Minor nonconformity indicators: an isolated or single-instance lapse in an otherwise implemented system, with limited impact on product or the QMS.

  • A nonconformity statement should cite the requirement, the objective evidence (record IDs, dates, observations), and the nature of the deficiency - without prescribing the fix.

  • FDA inspection outcomes are classified as NAI (No Action Indicated), VAI (Voluntary Action Indicated), and OAI (Official Action Indicated); individual observations are issued on Form FDA 483.

  • Correction = containment or repair of the detected condition; corrective action = action on the root cause to prevent recurrence; preventive action = action on potential causes to prevent occurrence. ISO 13485:2016 handles both under CAPA (Clause 8.5.2/8.5.3).

  • Verification of implementation confirms the action was done; verification of effectiveness confirms the nonconformity has not recurred and the process now conforms (evidence is taken after a defined period).

  • Audit report contents: objectives, scope, criteria, team and dates, summary of results, nonconformities with evidence references, conclusions on QMS effectiveness, and follow-up requirements.

  • Follow-up closure requires documented evidence, timely response against the agreed deadline, and escalation if the response or effectiveness evidence is inadequate.