Server Hardware Installation and Management

  • Rack unit (U) = 1.75 in (44.45 mm) of vertical space; a standard 42U rack provides about 73.5 in of usable height.

  • RAID 5 is striping with single parity and tolerates one drive failure; RAID 6 uses dual parity and tolerates two; RAID 10 tolerates one failed drive per mirror pair.

  • RDIMMs buffer address/command signals and are the typical choice for multi-socket servers; LRDIMMs use rank multiplication to reach much higher capacities at slightly higher latency.

  • ECC memory detects and corrects single-bit errors and detects double-bit errors; it requires CPU/chipset support, and ECC and non-ECC modules cannot be mixed in one server.

  • Rebuild time scales with drive capacity, not drive count: a large single replacement drive produces a longer, riskier rebuild window than several small drives.

  • Redundant PSUs should be fed from separate PDUs or circuits; N+1 sizing means any single PSU can carry the entire server load alone.

  • A BMC (iDRAC, iLO, IPMI) provides out-of-band power control, remote console, sensor readings, and event logs independent of the operating system.

  • Hot-swap replacement requires a compatible backplane and RAID controller, and the replacement drive should match or exceed the failed drive's capacity and interface.

  • UEFI replaces legacy BIOS, adds GPT boot support, and with Secure Boot validates bootloader signatures before the OS loads.

Quick reference

Server Administration

  • Least privilege: assign each account only the rights its role requires, and keep separate accounts for administrative tasks and daily use.

  • Type 1 hypervisors run directly on server hardware (ESXi, Hyper-V); type 2 hypervisors run as an application on top of a host OS.

  • VM snapshots capture a point-in-time disk delta, grow as the guest changes, and degrade performance when kept for long periods; they are not backups.

  • DNS record roles: A maps a name to IPv4, AAAA maps a name to IPv6, CNAME aliases one name to another name, PTR maps an address back to a name.

  • NTP stratum 1 servers sync directly to a reference clock; each additional stratum level increases distance from the reference and accumulates error.

  • SNMP traps are unsolicited alerts pushed from agent to manager on an event; polling reads OIDs on a schedule with GET/GETNEXT requests.

  • Patch deployment uses rings: a small pilot or canary group first, then wider rollout once stability is verified, with a documented rollback path.

  • RAID provides availability, not backup: it does not protect against deletion, corruption, malware, or loss of the site.

  • A DHCP reservation binds a fixed IP address to a specific MAC address, giving stable addressing while keeping configuration centralized.

Quick reference

Security and Disaster Recovery

  • The CIA triad (confidentiality, integrity, availability) is the basis for evaluating whether a control addresses the required risk.

  • Backup types: full copies all data; incremental copies changes since the last backup of any type; differential copies changes since the last full. Restores need the last full plus every incremental in order, or the last full plus the latest differential.

  • The 3-2-1 rule: at least three copies of data, on two different media types, with one copy stored offsite.

  • RTO is the maximum tolerable downtime; RPO is the maximum tolerable data loss. Recovery time increases from hot site to warm site to cold site.

  • TLS protects data in transit; full-disk or volume encryption, self-encrypting drives, and TPM-backed key storage protect data at rest.

  • Hardening baseline: disable unused services and ports, change default credentials, apply patches, enable the host firewall, and restrict remote management to a dedicated management network.

  • Incident response sequence: preparation, identification, containment, eradication, recovery, lessons learned.

  • Chain of custody must record who handled evidence, when, and where; an undocumented gap can make the evidence inadmissible.

  • MFA requires two or more different factors (something you know, have, or are); two passwords from the same factor category do not qualify.

Quick reference

Troubleshooting

  • Sequence: identify the problem and gather information, establish a theory of probable cause, test the theory, plan and implement the fix, verify full functionality, document findings.

  • Check for recent changes first; change one variable at a time and revert it if the symptom does not improve, so cause and effect stay attributable.

  • POST failures surface as beep codes, diagnostic LEDs, or BMC/IPMI system event log entries even when no video output is available.

  • Correctable ECC errors are logged and corrected automatically; uncorrectable errors raise machine checks and can crash the host. Repeated correctable errors on one DIMM indicate a failing module.

  • High CPU ready time on a VM indicates host CPU oversubscription; memory ballooning indicates host memory pressure that pushes the guest to swap.

  • SMART attributes such as reallocated sectors, pending sectors, and spin retry counts predict drive failure before the array degrades.

  • A degraded array is still serving data but has lost redundancy; a failed array has lost more members than its parity level can tolerate.

  • Network isolation order: physical link and switch port, then IP configuration, then gateway reachability, then name resolution, then the application layer.

  • Performance problems are diagnosed by comparing current metrics against a documented known-good baseline captured before the change or fault.