CompTIA Server+ study materials
CompTIA Server+ study resources

CompTIA Server+ key terms

CompTIA Server+ · Get comfortable with the vocabulary.

Rack Unit (U)

A standard vertical measurement equal to 1.75 inches (44.45 mm) used to describe the height of servers and rack-mounted equipment. A 2U server occupies two rack units, which helps when planning cabinet space, power, and airflow.

Related: Blade Server, Redundant Power Supply
Redundant Power Supply

Two or more power supplies feeding a single server or chassis so the system keeps running if one supply or its power feed fails. Supplies are usually hot-swappable and may connect to separate electrical circuits.

Related: Hot-Swap, Uninterruptible Power Supply (UPS)
Hot-Swap

A design feature that lets a component such as a drive, fan, or power supply be removed and replaced while the server stays powered on and serving workloads, avoiding scheduled downtime for routine hardware replacement.

Related: Redundant Power Supply, RAID
Baseboard Management Controller (BMC)

An independent controller on the motherboard that provides remote access to a server's power, console, and sensors even when the operating system is down. It is usually reached over a dedicated network port.

Related: POST, Diagnostic LEDs
RAID

A method of combining multiple physical drives into one logical unit to gain speed, fault tolerance, or both. Common levels include 0, 1, 5, 6, and 10, each with different cost and protection trade-offs.

Related: Hot-Swap, NVMe
ECC Memory

Memory that detects and corrects single-bit errors and reports larger faults, protecting servers that run continuously. ECC requires support from the motherboard, CPU, and memory modules working together.

Related: POST, Baseline
NVMe

A protocol for accessing solid-state storage over a PCIe bus rather than through a legacy disk controller. NVMe drives offer very low latency and deep queues, making them common for databases and virtualization hosts.

Related: RAID
Uninterruptible Power Supply (UPS)

A battery-backed device that keeps servers and network gear running during short power outages and smooths voltage sags. Larger units can signal servers to shut down gracefully when battery charge runs low.

Related: Redundant Power Supply
Blade Server

A thin modular server that slides into a shared chassis supplying power, cooling, networking, and management. Blades reduce cabling and rack space compared with standalone rack-mounted servers.

Related: Rack Unit (U), KVM Switch
Firmware

Low-level software stored on a device that controls basic hardware behavior, such as BIOS or UEFI, drive controllers, and network adapters. Updates fix bugs and security flaws but must be applied carefully.

Related: POST, Patch Management
KVM Switch

Hardware that lets one keyboard, monitor, and mouse control multiple servers. Rack-mounted KVM consoles are often used during maintenance when remote management access is unavailable.

Related: Baseboard Management Controller (BMC), Blade Server
Hypervisor

Software that runs virtual machines by sharing a host's CPU, memory, storage, and network among guests. A Type 1 hypervisor runs directly on hardware; Type 2 runs as an application on another operating system.

Related: Snapshot, NIC Teaming
Active Directory Domain Controller

A Windows server that stores directory data and handles authentication and authorization for a domain. Multiple controllers replicate with each other so logons continue if one server goes offline.

Related: Group Policy Object (GPO), Principle of Least Privilege
DHCP Scope

A defined range of IP addresses that a DHCP server can lease to clients, along with options such as default gateway, DNS servers, and lease duration. Separate scopes serve separate subnets.

Related: DNS Zone, VLAN
DNS Zone

A portion of the DNS namespace held on a server, containing records that map names to addresses and services. Forward zones resolve names to addresses; reverse zones resolve addresses to names.

Related: DHCP Scope
VLAN

A logical network segment created by configuring switches so devices share a broadcast domain regardless of physical location. VLANs separate traffic for security and reduce broadcast congestion on busy networks.

Related: NIC Teaming, DHCP Scope
NIC Teaming

Bonding two or more physical network adapters into one logical link to raise throughput or survive an adapter or cable failure. The attached switch must support the chosen teaming mode.

Related: VLAN, Loopback Plug
Group Policy Object (GPO)

A collection of configuration settings in Active Directory applied to users and computers in sites, domains, or organizational units. GPOs enforce security, software, and desktop standards across many servers.

Related: Active Directory Domain Controller, Server Hardening
Patch Management

A repeatable process for identifying, testing, deploying, and verifying updates to operating systems, applications, and firmware. It reduces exposure to known vulnerabilities while limiting disruption to production services.

Related: Firmware, Change Management
Baseline

A recorded measurement of normal server performance or configuration taken while the system is healthy. Later readings are compared against it to spot drift, bottlenecks, or unauthorized changes.

Related: Syslog, Root Cause Analysis
Snapshot

A point-in-time copy of a volume or virtual machine that can be rolled back quickly after a failed change. Snapshots are not a substitute for real backups kept on separate storage.

Related: Hypervisor, 3-2-1 Backup Rule
Syslog

A standard protocol and message format for sending event records from servers and network devices to a central collector. Centralized logging helps correlate events and preserve records after a failure.

Related: Baseline
Principle of Least Privilege

Granting users and services only the rights required to perform their duties, and no more. It limits the damage that compromised accounts or mistaken administrative changes can cause.

Related: Active Directory Domain Controller, Multifactor Authentication (MFA)
Multifactor Authentication (MFA)

Authentication requiring two or more independent factors, such as a password plus a code from a phone or a hardware token. It reduces the risk that stolen credentials alone lead to a breach.

Related: Principle of Least Privilege, Public Key Infrastructure (PKI)
Recovery Point Objective (RPO)

The maximum acceptable amount of data loss expressed in time before an incident. An RPO of one hour means backups or replication must capture data at least that often.

Related: Recovery Time Objective (RTO), 3-2-1 Backup Rule
Recovery Time Objective (RTO)

The maximum acceptable time to restore a service after a disruption. RTO drives the choice of recovery site, spare hardware, and automation in a continuity plan.

Related: Recovery Point Objective (RPO), Disaster Recovery Plan
3-2-1 Backup Rule

A practice of keeping at least three copies of data, on two different media types, with one copy stored off site. It protects against device failure, ransomware, and site-wide disasters.

Related: Snapshot, Disaster Recovery Plan
Disaster Recovery Plan

A documented set of procedures, roles, and resources for restoring IT services after a major outage. It is tested on a schedule and updated as systems and business needs change.

Related: Recovery Time Objective (RTO), Change Management
Server Hardening

Reducing a server's attack surface by removing unneeded services, closing unused ports, applying secure configuration, restricting accounts, and enabling auditing. The result is validated against a documented standard.

Related: Group Policy Object (GPO), Patch Management
Public Key Infrastructure (PKI)

The combination of certificate authorities, policies, and software that issues and validates digital certificates. Servers use it for encrypted web traffic, authentication, and code or configuration signing.

Related: Multifactor Authentication (MFA)
Chain of Custody

A documented record of who handled evidence, when, and where, from collection through storage and analysis. It keeps forensic findings admissible and defensible during an investigation.

Related: Root Cause Analysis
POST

A self-test the server firmware runs at power-on to check the CPU, memory, and core devices before loading the operating system. Failures are reported through beep codes, indicator lights, or log entries.

Related: Diagnostic LEDs, Baseboard Management Controller (BMC)
Diagnostic LEDs

Indicators on the chassis, motherboard, or components that show power state, drive activity, fan faults, or specific error conditions. They narrow down hardware problems when a server will not boot.

Related: POST, Baseboard Management Controller (BMC)
Loopback Plug

A connector that sends a port's transmit signal back to its own receive pin to verify that the interface and driver work. It helps separate a failed adapter from a cabling or switch problem.

Related: NIC Teaming
Root Cause Analysis

A structured investigation that moves past the immediate symptom to find the underlying reason an incident occurred, then records corrective actions so the same problem does not return.

Related: Baseline, Escalation
Change Management

A controlled process for requesting, reviewing, approving, scheduling, and rolling back changes to production systems. It reduces outages caused by untested or undocumented modifications.

Related: Patch Management, Disaster Recovery Plan
Escalation

Passing an unresolved issue to a more skilled person, team, or vendor according to defined criteria and time limits. It keeps incidents moving and sets clear expectations for the user.

Related: Root Cause Analysis, Change Management
Kernel Panic

A fatal error in which the operating system kernel detects an unrecoverable condition and halts the machine. The crash dump and logs help identify faulty drivers, memory, or hardware.

Related: POST, Root Cause Analysis