CompTIA Server+ key terms
CompTIA Server+ · Get comfortable with the vocabulary.
- Rack Unit (U)
- Related: Blade Server, Redundant Power Supply
A standard vertical measurement equal to 1.75 inches (44.45 mm) used to describe the height of servers and rack-mounted equipment. A 2U server occupies two rack units, which helps when planning cabinet space, power, and airflow.
- Redundant Power Supply
- Related: Hot-Swap, Uninterruptible Power Supply (UPS)
Two or more power supplies feeding a single server or chassis so the system keeps running if one supply or its power feed fails. Supplies are usually hot-swappable and may connect to separate electrical circuits.
- Hot-Swap
- Related: Redundant Power Supply, RAID
A design feature that lets a component such as a drive, fan, or power supply be removed and replaced while the server stays powered on and serving workloads, avoiding scheduled downtime for routine hardware replacement.
- Baseboard Management Controller (BMC)
- Related: POST, Diagnostic LEDs
An independent controller on the motherboard that provides remote access to a server's power, console, and sensors even when the operating system is down. It is usually reached over a dedicated network port.
- RAID
- Related: Hot-Swap, NVMe
A method of combining multiple physical drives into one logical unit to gain speed, fault tolerance, or both. Common levels include 0, 1, 5, 6, and 10, each with different cost and protection trade-offs.
- ECC Memory
- Related: POST, Baseline
Memory that detects and corrects single-bit errors and reports larger faults, protecting servers that run continuously. ECC requires support from the motherboard, CPU, and memory modules working together.
- NVMe
- Related: RAID
A protocol for accessing solid-state storage over a PCIe bus rather than through a legacy disk controller. NVMe drives offer very low latency and deep queues, making them common for databases and virtualization hosts.
- Uninterruptible Power Supply (UPS)
- Related: Redundant Power Supply
A battery-backed device that keeps servers and network gear running during short power outages and smooths voltage sags. Larger units can signal servers to shut down gracefully when battery charge runs low.
- Blade Server
- Related: Rack Unit (U), KVM Switch
A thin modular server that slides into a shared chassis supplying power, cooling, networking, and management. Blades reduce cabling and rack space compared with standalone rack-mounted servers.
- Firmware
- Related: POST, Patch Management
Low-level software stored on a device that controls basic hardware behavior, such as BIOS or UEFI, drive controllers, and network adapters. Updates fix bugs and security flaws but must be applied carefully.
- KVM Switch
- Related: Baseboard Management Controller (BMC), Blade Server
Hardware that lets one keyboard, monitor, and mouse control multiple servers. Rack-mounted KVM consoles are often used during maintenance when remote management access is unavailable.
- Hypervisor
- Related: Snapshot, NIC Teaming
Software that runs virtual machines by sharing a host's CPU, memory, storage, and network among guests. A Type 1 hypervisor runs directly on hardware; Type 2 runs as an application on another operating system.
- Active Directory Domain Controller
- Related: Group Policy Object (GPO), Principle of Least Privilege
A Windows server that stores directory data and handles authentication and authorization for a domain. Multiple controllers replicate with each other so logons continue if one server goes offline.
- DHCP Scope
- Related: DNS Zone, VLAN
A defined range of IP addresses that a DHCP server can lease to clients, along with options such as default gateway, DNS servers, and lease duration. Separate scopes serve separate subnets.
- DNS Zone
- Related: DHCP Scope
A portion of the DNS namespace held on a server, containing records that map names to addresses and services. Forward zones resolve names to addresses; reverse zones resolve addresses to names.
- VLAN
- Related: NIC Teaming, DHCP Scope
A logical network segment created by configuring switches so devices share a broadcast domain regardless of physical location. VLANs separate traffic for security and reduce broadcast congestion on busy networks.
- NIC Teaming
- Related: VLAN, Loopback Plug
Bonding two or more physical network adapters into one logical link to raise throughput or survive an adapter or cable failure. The attached switch must support the chosen teaming mode.
- Group Policy Object (GPO)
- Related: Active Directory Domain Controller, Server Hardening
A collection of configuration settings in Active Directory applied to users and computers in sites, domains, or organizational units. GPOs enforce security, software, and desktop standards across many servers.
- Patch Management
- Related: Firmware, Change Management
A repeatable process for identifying, testing, deploying, and verifying updates to operating systems, applications, and firmware. It reduces exposure to known vulnerabilities while limiting disruption to production services.
- Baseline
- Related: Syslog, Root Cause Analysis
A recorded measurement of normal server performance or configuration taken while the system is healthy. Later readings are compared against it to spot drift, bottlenecks, or unauthorized changes.
- Snapshot
- Related: Hypervisor, 3-2-1 Backup Rule
A point-in-time copy of a volume or virtual machine that can be rolled back quickly after a failed change. Snapshots are not a substitute for real backups kept on separate storage.
- Syslog
- Related: Baseline
A standard protocol and message format for sending event records from servers and network devices to a central collector. Centralized logging helps correlate events and preserve records after a failure.
- Principle of Least Privilege
- Related: Active Directory Domain Controller, Multifactor Authentication (MFA)
Granting users and services only the rights required to perform their duties, and no more. It limits the damage that compromised accounts or mistaken administrative changes can cause.
- Multifactor Authentication (MFA)
- Related: Principle of Least Privilege, Public Key Infrastructure (PKI)
Authentication requiring two or more independent factors, such as a password plus a code from a phone or a hardware token. It reduces the risk that stolen credentials alone lead to a breach.
- Recovery Point Objective (RPO)
- Related: Recovery Time Objective (RTO), 3-2-1 Backup Rule
The maximum acceptable amount of data loss expressed in time before an incident. An RPO of one hour means backups or replication must capture data at least that often.
- Recovery Time Objective (RTO)
- Related: Recovery Point Objective (RPO), Disaster Recovery Plan
The maximum acceptable time to restore a service after a disruption. RTO drives the choice of recovery site, spare hardware, and automation in a continuity plan.
- 3-2-1 Backup Rule
- Related: Snapshot, Disaster Recovery Plan
A practice of keeping at least three copies of data, on two different media types, with one copy stored off site. It protects against device failure, ransomware, and site-wide disasters.
- Disaster Recovery Plan
- Related: Recovery Time Objective (RTO), Change Management
A documented set of procedures, roles, and resources for restoring IT services after a major outage. It is tested on a schedule and updated as systems and business needs change.
- Server Hardening
- Related: Group Policy Object (GPO), Patch Management
Reducing a server's attack surface by removing unneeded services, closing unused ports, applying secure configuration, restricting accounts, and enabling auditing. The result is validated against a documented standard.
- Public Key Infrastructure (PKI)
- Related: Multifactor Authentication (MFA)
The combination of certificate authorities, policies, and software that issues and validates digital certificates. Servers use it for encrypted web traffic, authentication, and code or configuration signing.
- Chain of Custody
- Related: Root Cause Analysis
A documented record of who handled evidence, when, and where, from collection through storage and analysis. It keeps forensic findings admissible and defensible during an investigation.
- POST
- Related: Diagnostic LEDs, Baseboard Management Controller (BMC)
A self-test the server firmware runs at power-on to check the CPU, memory, and core devices before loading the operating system. Failures are reported through beep codes, indicator lights, or log entries.
- Diagnostic LEDs
- Related: POST, Baseboard Management Controller (BMC)
Indicators on the chassis, motherboard, or components that show power state, drive activity, fan faults, or specific error conditions. They narrow down hardware problems when a server will not boot.
- Loopback Plug
- Related: NIC Teaming
A connector that sends a port's transmit signal back to its own receive pin to verify that the interface and driver work. It helps separate a failed adapter from a cabling or switch problem.
- Root Cause Analysis
- Related: Baseline, Escalation
A structured investigation that moves past the immediate symptom to find the underlying reason an incident occurred, then records corrective actions so the same problem does not return.
- Change Management
- Related: Patch Management, Disaster Recovery Plan
A controlled process for requesting, reviewing, approving, scheduling, and rolling back changes to production systems. It reduces outages caused by untested or undocumented modifications.
- Escalation
- Related: Root Cause Analysis, Change Management
Passing an unresolved issue to a more skilled person, team, or vendor according to defined criteria and time limits. It keeps incidents moving and sets clear expectations for the user.
- Kernel Panic
- Related: POST, Root Cause Analysis
A fatal error in which the operating system kernel detects an unrecoverable condition and halts the machine. The crash dump and logs help identify faulty drivers, memory, or hardware.