CI-CPT study materials
CI-CPT study resources

CI-CPT flashcards

CI-CPT · Build recall with a focused review session.

32 cards. Read the term and the definition here. The deck at the top of this page is optional.

Order of draw
Sequence for filling venous tubes to prevent additive cross-contamination: culture, citrate, serum, heparin, EDTA, then glycolytic inhibitor tubes.
Citrate tube fill requirement
Sodium citrate tubes must be filled to at least 90 percent of nominal volume; underfilling falsely prolongs PT and aPTT results.
Tourniquet time limit
Tourniquet should remain on no longer than one minute; longer stasis causes hemoconcentration, raising potassium and protein and promoting hemolysis.
Hemolysis effect on potassium
Red cell rupture releases intracellular potassium, falsely elevating measured potassium; hemolyzed specimens are typically rejected for potassium testing.
Preferred venipuncture vein
The median cubital vein is first choice because it is large, well anchored, and remote from the brachial artery and major nerves.
Capillary puncture first drop
Wipe away the first drop of capillary blood because it contains tissue fluid and may dilute the sample or alter results.
Blood culture volume
Adults typically require 20 to 30 mL per culture set, divided between aerobic and anaerobic bottles, collected before antimicrobial therapy begins.
Serum clotting time
Serum tubes should clot for about 30 minutes at room temperature before centrifugation to prevent fibrin strands from interfering with analysis.
Separation within two hours
Serum or plasma should be separated from cells within two hours of collection to limit potassium rise and glucose consumption by cells.
Light-sensitive analytes
Bilirubin, vitamin B12, folate, and porphyrins degrade with light exposure and require amber tubes or foil wrapping during handling.
Cold agglutinin transport
Cold agglutinins and cryoglobulins require transport and separation at 37 degrees Celsius; chilling causes antibody binding and invalid results.
Ammonia specimen handling
Ammonia specimens require immediate icing and rapid plasma separation because red cells release ammonia and falsely elevate results at room temperature.
Specimen rejection criteria
Common rejection reasons include unlabeled tubes, gross hemolysis, clotted anticoagulated samples, short citrate fills, and expired collection devices.
EDTA carryover effect
EDTA chelates calcium, so carryover into a later tube can falsely lower calcium and alkaline phosphatase; proper order of draw prevents this.
Fasting requirement
Most lipid and glucose testing requires 8 to 12 hours without caloric intake; water is permitted and does not alter results.
Two patient identifiers
Verify identity using two independent identifiers such as full name and date of birth, checked against the requisition at the bedside.
Needlestick first aid
Wash the exposed site with soap and water without squeezing, then report immediately for post-exposure evaluation and prophylaxis decisions.
Syncope prevention
Draw patients with a fainting history while lying down and remain with them until bleeding stops to prevent injury from a fall.
Antiseptic site preparation
Cleanse with 70 percent isopropyl alcohol in concentric circles and allow it to air dry completely before puncture for effective antisepsis.
Hemoconcentration causes
Prolonged tourniquet time, vigorous fist pumping, and drawing above an IV site concentrate cells and falsely raise potassium and protein.
Standard precautions
Gloves are required for every venipuncture, with gown, mask, and eye protection added when splash or spray exposure is anticipated.
POC glucose hematocrit effect
High hematocrit lowers whole-blood glucose readings and low hematocrit raises them, so anemia can falsely elevate meter results.
POC quality control
Meters require documented quality control, calibration verification, and correlation with central laboratory results per accreditation standards.
POC INR interference
Whole-blood INR devices are affected by hematocrit and lupus anticoagulant; discrepant results require central laboratory confirmation.
Air bubble effect on blood gas
Air bubbles shift pH, pCO2, and pO2 in blood gas samples; expel bubbles and analyze within minutes of collection.
POC strip lot verification
Confirm lot number, expiration date, and proper storage before use, and record operator identity and control results with each test.
POC critical value reporting
Critical point-of-care results must be verified and communicated per policy to the responsible provider, not simply entered into the chart.
Patient confidentiality
Results and identifiers are disclosed only to authorized care team members and never discussed in public areas or with unauthorized persons.
Informed consent elements
Explain the procedure, its risks such as bruising and fainting, and the patient's right to refuse or ask questions before collection.
Interpreter requirement
Use a qualified medical interpreter for patients with limited language proficiency; family members should not interpret clinical information.
Phlebotomy scope of practice
Phlebotomists may collect, label, and transport specimens but must not interpret results or give clinical advice to patients.
Error disclosure
Report collection errors, mislabeling, or adverse events promptly and factually through the facility incident reporting process.