CPSGT key terms
CPSGT · Get comfortable with the vocabulary.
- Polysomnography (PSG)
- Related: Sleep architecture, Montage, Epoch
A simultaneous recording of brain waves, eye movements, muscle tone, breathing, blood oxygen, heart rhythm, and body position during sleep, used to diagnose sleep disorders and to evaluate treatment.
- Sleep architecture
- Related: Sleep efficiency, Stage N2, REM sleep
The overall pattern and proportions of sleep stages across a night, including how much time is spent in N1, N2, N3, and REM and how often the person wakes.
- Stage N1
- Related: EOG, Sleep latency, Stage N2
The lightest sleep stage, marked by low-amplitude mixed-frequency EEG, slow rolling eye movements, and fading alpha rhythm; it is the transition from wakefulness into sleep.
- Stage N2
- Related: Sleep spindle, K-complex, Stage N3
A sleep stage defined by sleep spindles and K-complexes on EEG without the amount of slow-wave activity required for N3; it makes up the largest share of adult sleep.
- Stage N3
- Related: Epoch, EEG, Sleep architecture
Deep sleep, also called slow-wave sleep, defined by high-amplitude, low-frequency delta waves occupying at least 20 percent of a 30-second epoch.
- REM sleep
- Related: Chin EMG, EOG, Arousal
A sleep stage with rapid eye movements, low-amplitude mixed-frequency EEG, and very low chin muscle tone, in which most vivid dreaming occurs and breathing becomes irregular.
- Sleep spindle
- Related: Stage N2, EEG, K-complex
A short burst of 11-16 Hz waves lasting at least half a second, seen on EEG mostly in stage N2 and used as a key marker when scoring sleep stages.
- K-complex
- Related: Stage N2, Sleep spindle, Arousal
A sharply negative-then-positive, high-amplitude EEG wave lasting at least half a second, often triggered by a noise or internal stimulus, that helps define stage N2.
- Arousal
- Related: REM sleep, Hypopnea, Sleep architecture
An abrupt shift in EEG frequency lasting at least three seconds during sleep, which may or may not fully wake the person, and is counted when measuring sleep fragmentation.
- Sleep latency
- Related: Epoch, Sleep efficiency, Multiple Sleep Latency Test (MSLT)
The time from lights out to the first epoch scored as sleep; a short latency suggests high sleepiness, while a long one suggests difficulty falling asleep.
- Sleep efficiency
- Related: Sleep latency, Sleep architecture
Total sleep time divided by time in bed, multiplied by 100; a simple measure of how much of the night was actually spent asleep.
- Apnea-Hypopnea Index (AHI)
- Related: Hypopnea, Obstructive sleep apnea (OSA), PAP titration study
The number of apneas plus hypopneas per hour of sleep; it is the main figure used to classify obstructive sleep apnea as mild, moderate, or severe.
- Obstructive sleep apnea (OSA)
- Related: Hypopnea, Apnea-Hypopnea Index (AHI), RIP belts
Repeated collapse of the upper airway during sleep that reduces or stops airflow despite continued breathing effort, causing arousals and drops in blood oxygen.
- Hypopnea
- Related: Nasal pressure transducer, Pulse oximeter, Arousal
A partial reduction in airflow during sleep lasting at least ten seconds that meets scoring criteria, usually a clear fall in airflow with an associated oxygen desaturation or arousal.
- Circadian rhythm
- Related: Sleep latency, Sleep architecture
The roughly 24-hour internal clock that regulates sleep-wake timing, body temperature, and hormone release, and that can be shifted by light exposure and schedule changes.
- Periodic limb movements (PLM)
- Related: Arousal, Chin EMG
Repetitive, stereotyped limb movements, usually leg jerks, that occur in series during sleep and are detected with leg EMG to evaluate periodic limb movement disorder.
- International 10-20 system
- Related: EEG, Electrode impedance, Montage
A standard map of skull landmarks used to place EEG electrodes at consistent locations so recordings can be compared across technologists, nights, and laboratories.
- Electrode impedance
- Related: Skin preparation, Artifact, 60-Hz interference
The electrical resistance where an electrode meets the skin; it must be low enough, commonly under 5 kilohms, to record a clean signal without extra artifact.
- Skin preparation
- Related: Electrode impedance, Artifact
Cleaning and gently abrading the skin before applying electrodes to remove oils and dead cells, which lowers impedance and improves signal quality.
- Body position sensor
- Related: RIP belts, Technologist notes
A device, often worn on the chest or built into the belts, that records whether the patient lies supine, prone, or on either side, since apnea is often worse on the back.
- Nasal pressure transducer
- Related: Hypopnea, Thermistor, Artifact
A cannula at the nostrils that senses airflow through pressure changes during breathing; it is the preferred sensor for detecting and scoring hypopneas.
- Thermistor
- Related: Nasal pressure transducer, Hypopnea
A sensor placed at the nose and mouth that detects airflow by temperature change, cooler on inspiration and warmer on expiration, and is used mainly to score apneas.
- RIP belts
- Related: Obstructive sleep apnea (OSA), Body position sensor, Biocalibration
Elastic bands around the chest and abdomen that measure breathing effort by sensing changes in cross-sectional area, helping separate obstructive from central respiratory events.
- Pulse oximeter
- Related: Hypopnea, Escalation of urgent findings
A finger or ear probe that continuously estimates blood oxygen saturation and pulse rate using light absorption, supplying the desaturation data paired with respiratory events.
- Continuous positive airway pressure (CPAP)
- Related: PAP titration study, Mask fitting, Obstructive sleep apnea (OSA)
A device that delivers a steady flow of pressurized air through a mask to hold the upper airway open during sleep; it is the primary treatment for obstructive sleep apnea.
- Biocalibration
- Related: Montage, EOG, Chin EMG
A short set of instructed movements before lights out, such as eye movements, blinks, jaw clench, leg lifts, and breathing, that confirms each channel works and is correctly labeled.
- Epoch
- Related: Sleep latency, Stage N3, Arousal
A fixed 30-second block of polysomnographic data; sleep stages and most events are scored block by block, so timing on a report is given in these units.
- Montage
- Related: International 10-20 system, EEG, Biocalibration
The ordered list showing which electrodes are paired and displayed on each channel, defining how signals appear on screen and which channels the scorer reviews.
- Low-frequency filter
- Related: Artifact, Sensitivity (gain), EEG
A setting that removes slow drifting signal below a chosen frequency, reducing sweat and movement sway so faster brain and muscle activity is easier to see.
- Sensitivity (gain)
- Related: Low-frequency filter, Artifact, EEG
The setting that controls how much a signal is amplified for display, so waves of expected size fill the channel without being clipped or becoming too small to read.
- Artifact
- Related: 60-Hz interference, Electrode impedance, Sensitivity (gain)
Any signal on a channel that comes from something other than the source being measured, such as movement, sweat, electrical interference, or a loose electrode.
- 60-Hz interference
- Related: Electrode impedance, Artifact, Skin preparation
Electrical noise from building wiring that appears as a thick, fuzzy band on a channel, usually caused by high electrode impedance or a poor connection.
- Chin EMG
- Related: REM sleep, Biocalibration, EOG
Electrodes placed under the chin that record muscle tone; the level of tone helps separate REM sleep, where it is lowest, from the other stages.
- EOG
- Related: Stage N1, REM sleep, Biocalibration
Electrodes placed near the eyes that record eye movements, showing slow rolling movements in stage N1 and rapid movements during REM sleep.
- EEG
- Related: Sleep spindle, Stage N2, International 10-20 system
Recording of brain electrical activity from scalp electrodes; the frequency and amplitude patterns seen are used to identify wakefulness and each sleep stage.
- PAP titration study
- Related: Continuous positive airway pressure (CPAP), Split-night study, Apnea-Hypopnea Index (AHI)
A sleep study in which the technologist adjusts positive airway pressure, and sometimes mask type or mode, to find the setting that best controls breathing events during sleep.
- Split-night study
- Related: PAP titration study, Technologist notes
A single-night study in which the first portion is diagnostic and, when criteria are met, the remaining portion is used to begin and adjust positive airway pressure treatment.
- Technologist notes
- Related: Body position sensor, Escalation of urgent findings, Split-night study
Written documentation during the study of events, interventions, patient complaints, and equipment changes, forming the record that supports scoring, interpretation, and any later review.
- Escalation of urgent findings
- Related: Pulse oximeter, Technologist notes
The process of promptly notifying the supervising clinician or on-call staff about dangerous observations, such as severe oxygen desaturation, arrhythmia, or unsafe patient behavior.
- Mask fitting
- Related: Continuous positive airway pressure (CPAP), PAP titration study
Selecting and adjusting a CPAP mask for comfort and minimal leak, then teaching the patient how to put it on, take it off, and clean it at home.