CT Crane Operator study materials
CT Crane Operator study resources

Off-Center Tank Lift with Asymmetric Sling Tensions

CT Crane Operator · Put your knowledge to work in context.

All case studies

Off-Center Tank Lift with Asymmetric Sling Tensions

An 8,000 lb rectangular tank is to be lifted by a four-leg bridle using two lugs, one 2 ft from each end of the 12 ft tank. The tank's center of gravity is 4 ft from the left end, not at mid-length, because a pump is mounted on that end. Each lug is rigged with two 1/2 in wire rope slings in a choker hitch; each sling's tag shows a 4,000 lb vertical capacity and a 3,000 lb choker capacity. The sling pairs form a 60° included angle at each lug, so each leg is 30° from vertical. The rigger plans to lift slowly and use a tag line. A 1-ton shackle is used at each lug. The load must clear a 42 in pipe rack.

1. Calculate the vertical reaction at each lifting lug and explain why assuming equal sharing is wrong.

Read the worked answer

Take moments about the center of gravity. The left lug is 2 ft from the CG; the right lug is 6 ft from the CG. R_left × 2 = R_right × 6 and R_left + R_right = 8,000 lb. Thus R_left = 6,000 lb and R_right = 2,000 lb. Equal 4,000 lb per lug would overload the left lug by 50% and understate the right lug. The pump location is the reason the CG is off-center, and the rigger must verify the CG rather than assume a symmetric tank.

2. Calculate the tension in each sling leg and determine whether the rigging is acceptable.

Read the worked answer

At the left lug, each of the two slings carries half the vertical reaction: 3,000 lb vertical. With the leg 30° from vertical, tension = 3,000 ÷ cos 30° = 3,464 lb. The sling's choker capacity is 3,000 lb, so each left sling is overloaded by about 15%. The right slings carry 1,000 ÷ cos 30° = 1,155 lb each and are acceptable. The left 1-ton shackle is also unacceptable: it sees the 6,000 lb lug reaction, three times its 2,000 lb rating. The first failure point is the left shackle, followed by the left slings.

3. What rigging changes or pre-lift actions are required before this tank can be lifted?

Read the worked answer

Do not lift as rigged. Replace the left shackle with one rated for at least the lug reaction with a suitable design factor, and use slings whose choker capacity exceeds 3,464 lb at the actual angle. Better, use a spreader beam or adjust the lifting points so the CG is centered between the lugs, or use a four-point pick with verified load share. Confirm the tank lugs and their welds are rated for 6,000 lb. Recheck the pipe rack clearance after the load hangs level; an off-center CG will make the tank tilt.