CT Plumber study materials
CT Plumber study resources

CT Plumber cheat sheet

CT Plumber · Keep the key ideas within reach.

Quick reference

General Plumbing Regulations, Licensing, and Code Administration

  • Connecticut plumbers are licensed by the Department of Consumer Protection (DCP) under Conn. Gen. Stat. Chapter 393; the Plumbing and Piping Work Board advises DCP on licensing and code matters.

  • License tiers are P-1 (journeyperson) and P-2 (master); an apprentice (P-7) may perform plumbing work only under direct supervision of a licensed P-1 or P-2.

  • The State Plumbing Code is the Connecticut State Building Code's Plumbing Code, based on the International Plumbing Code with Connecticut amendments; local ordinances may be stricter but not less stringent.

  • Permits are required before installation, alteration, replacement, or repair of plumbing systems except ordinary minor repairs; work without a permit is a code violation subject to stop-work orders and fines.

  • A permit is valid for 180 days and may be extended; inspections must be requested at required stages (underground, rough-in, final) before concealment of piping.

  • Code administration follows the appeal chain: local building official, then the State Building Code Standards Committee (with DCP involvement for licensing matters).

  • Only a licensed contractor may contract for plumbing work; a P-2 may hold the license for a plumbing contracting business, and a P-1 may work only under such a contractor's authority.

  • Continuing education and license renewal occur on a fixed cycle; practicing on an expired or suspended license is grounds for disciplinary action and civil penalties.

  • Connecticut amendments supersede model-code text where they conflict; when the code is silent, manufacturer instructions and accepted engineering practice govern.

Quick reference

General Regulations and Safety Requirements

  • All plumbing materials, fixtures, and devices must be listed by a recognized testing agency (e.g., ASSE, CSA, UL) and installed per the manufacturer's instructions.

  • A minimum 1-inch air gap or an approved backflow prevention assembly is required at every cross-connection; RPZ assemblies are tested at installation and annually.

  • Water heaters must be protected by a temperature and pressure relief valve piped full size to a safe point of discharge, with no trap and no reduction in pipe size.

  • Combustion air and venting for fuel-fired appliances must conform to the code; safety devices (spill switches, flame rollout switches) may not be bypassed.

  • Plumbing work must not be concealed before inspection; rough-in inspections are required after piping is installed but before covering.

  • Pipes must be protected from freezing, corrosion, and physical damage; sleeves are required where piping passes through foundations or masonry.

  • Excavations for underground piping deeper than 5 feet require shoring or sloping; trenching safety follows OSHA 29 CFR 1926 Subpart P.

  • Piping must be supported at code intervals and not used to support other loads; hangers, anchors, and guides must allow for thermal expansion.

  • Water pressure must be controlled: where static pressure exceeds 80 psi, a pressure-reducing valve is required; thermal expansion control is required on closed systems.

Quick reference

Fixtures, Faucets, and Fixture Fittings

  • Water closets may not exceed 1.6 gallons per flush; urinals may not exceed 1.0 gpf; residential showerheads are limited to 2.5 gpm at 80 psi.

  • Residential kitchen faucets are limited to 2.2 gpm; lavatory faucets to 2.2 gpm at 60 psi; metering and public-use fixtures have separate limits.

  • Each fixture must be individually valved, accessible, and connected to a code-compliant trap; fixtures with a concealed trap must have an accessible cleanout.

  • Fixture clearances: water closets require at least 15 inches from centerline to sidewall and 21 inches in front of the bowl; lavatories similar side clearance.

  • A water closet must be set level, securely fastened to the flange, and sealed with an approved wax or elastomer gasket; flange must be at or above finished floor.

  • Drinking fountains must have an adjustable stream regulator and be protected from backflow; hand sinks in food handling areas require an air gap or vacuum breaker.

  • Fixture drains must be at least 1-1/4 inch for lavatories, 1-1/2 inch for kitchen sinks and tubs, and 3 inch for water closets.

  • Shower valves must be pressure-balancing or thermostatic, and shower floors must slope 1/4 inch per foot to the drain with a curb or threshold.

Quick reference

Water Heaters and Hot Water Supply Systems

  • Temperature and pressure relief valves must be set at or below the heater's rated pressure and 210°F, with the discharge pipe terminating 6 to 24 inches above the floor or outside.

  • A vacuum relief valve is required where the heater is installed with a bottom inlet and no check valve, or where code requires it to prevent back-siphonage.

  • Water heaters must be accessible for service and inspection; seismic strapping is not required in Connecticut, but anchoring against tipping is prudent.

  • Gas-fired water heaters require proper venting, combustion air, and a sediment trap on the gas line; the appliance connector cannot pass through a wall.

  • Expansion tanks are required on closed systems with backflow prevention; a thermal expansion control device prevents T&P relief discharge from pressure cycling.

  • Hot water distribution must be insulated where required; recirculation systems must be balanced, and dead legs are limited by code.

  • Combination space and water heating systems must be listed for that use; the potable water side must be protected from contamination.

  • Hot water storage tanks must be supported on a level, noncombustible base and protected from physical damage; heaters in garages must be elevated 18 inches above the floor.

Quick reference

Water Supply and Distribution Piping

  • Minimum service pipe size is 3/4 inch for a single-family dwelling; sizing follows the fixture-unit method or the code's tables.

  • Static pressure must be at least 8 psi at the fixture outlet under flow; where pressure exceeds 80 psi, a PRV is required.

  • Water service lines must be buried below the frost depth (36 inches in Connecticut) or otherwise protected from freezing.

  • Backflow protection: hose bibbs require vacuum breakers; sillcocks must be frost-proof; RPZ or double-check assemblies are required at service connections where hazard exists.

  • Piping must slope to drain at 1/4 inch per foot where drain-down is required, and be supported per material-specific spacing (e.g., copper horizontal every 6 feet).

  • Water piping must not be installed in the same trench as sewer unless separated by 12 inches vertically or 5 feet horizontally with the water above the sewer.

  • Shutoff valves are required on the service, on each fixture branch, and on the main; drain valves are required at low points.

  • PEX and CPVC must be installed per manufacturer instructions and listing; PEX requires protection from UV and from physical damage at penetrations.

Quick reference

Sanitary Drainage and Venting Systems

  • Fixture units convert different fixture types into a common drainage load; a 4-inch building drain handles about 216 fixture units at 1/4 inch per foot slope.

  • Slope requirements: 2-1/2 inch and smaller drain pipe at 1/4 inch per foot; 3 inch and larger may slope at 1/8 inch per foot where approved.

  • Each trap must be vented; the vent must be taken within the trap-to-vent distance, which is 5 feet for 1-1/2 inch and 3 feet for 1-1/4 inch traps.

  • A vent stack must extend at least 6 inches above the roof or above the snow line; a 1-1/2 inch vent is the minimum for a single fixture.

  • Wet venting is limited: a wet vent may serve only one or two fixtures and must be at least 2 inches; the total fall may not exceed the pipe diameter.

  • Cleanouts are required at the base of the stack, at the building drain, and every 100 feet horizontally; cleanouts must be accessible and full size.

  • Horizontal drainage piping must be supported at intervals of 4 feet for 2-inch and smaller, and 10 feet for larger pipe; vertical stacks every floor.

  • A building drain must be at least 3 inches and connect to the building sewer, which must be at least 3 inches and sloped to the public sewer.

  • Backwater valves are required where the building drain is below the flood level rim of the lowest fixture; they must be accessible for service.

Quick reference

Storm Drainage Systems

  • Roof drainage is sized by the 100-year, 1-hour rainfall intensity for the site; leaders and gutters are sized from the roof area and rainfall rate.

  • Primary roof drains must be sized to carry the design rainfall; secondary (overflow) drains or scuppers are required to handle the design storm.

  • Storm drainage may not connect to the sanitary sewer; separate storm systems are required and must discharge to an approved point of disposal.

  • Roof drain strainers must be at least 4 inches in diameter and have an open area at least twice the leader's cross-section.

  • Storm leaders must be supported per code and must be protected from freezing; leaders may not be used as a vent.

  • Sump pumps and storm water pumps must be installed with check valves and discharge to an approved point; discharge may not create a nuisance or hazard.

  • Area drains and trench drains must be trapped if connected to the storm system, and traps must be protected from evaporation.

  • Storm water must not be discharged onto a neighboring property or into a sanitary sewer; downspouts must terminate at least 3 feet from the foundation where practical.

  • Sizing tables give leader and drain sizes based on roof area in square feet and rainfall in inches per hour; the code's tables must be used, not guesswork.

Quick reference

Traps, Interceptors, and Special Wastes

  • Every trap must have a liquid seal of 2 to 4 inches; traps must be self-cleaning, with a uniform bore and a cleanout on traps 3 inches and larger.

  • A grease interceptor is required for commercial kitchens and must be sized by fixture units, with a capacity based on the code's formula; the flow rate and grease retention capacity must both be met.

  • Grease interceptors must be installed outside the building, accessible for cleaning, and vented; the inlet and outlet must be baffled.

  • A sand and oil interceptor is required for garage and repair facilities; the interceptor must be sized for the discharge and have a vent.

  • Special wastes (acid, chemical, photographic) require approved neutralization or dilution tanks; the material of the tank and piping must resist the waste.

  • Traps may not be double-trapped or trap-sealed by a second trap; a trap may serve only one fixture except where code allows a combination fixture.

  • A trap primer is required for floor drains that may lose their seal; the primer must be accessible and connected to a potable water source with backflow protection.

  • Clothes washer standpipes must be at least 18 inches and not more than 42 inches above the trap, with a 2-inch trap and vent.

  • Interceptors may not be installed where they would be subject to freezing; cleanouts and covers must be gas-tight and accessible.

Quick reference

Fuel Gas Piping and Appliances

  • Gas piping must be sized using the code's tables based on the total connected load in BTU/hr, the length of the longest run, and the specific gravity of the gas.

  • A sediment trap is required at each appliance and must be installed downstream of the shutoff valve, with the trap leg vertical.

  • A shutoff valve is required within 6 feet of each appliance; a union or flanged connection is required for appliance removal.

  • Gas piping must be supported every 6 feet for horizontal runs and every 10 feet for vertical runs, and must not be concealed in a way that prevents inspection.

  • Combustion air for appliances in confined spaces is calculated from the volume of the space and the input rating; two openings are required, one near the top and one near the bottom.

  • Gas piping must be tested at 1-1/2 times the working pressure but not less than 3 psi for a minimum of 10 minutes for low-pressure systems.

  • Appliance connectors must be listed and may not pass through walls, ceilings, or floors; the connector length is limited (typically 6 feet for a flexible connector).

  • A gas water heater in a garage must be elevated 18 inches above the floor to protect the ignition source from vapors.

  • Gas piping may not be installed in a duct, chimney, or concealed space without protection; it must be protected from corrosion and physical damage.

Quick reference

Isometric Drawing and Plan Reading

  • An isometric drawing shows piping in three dimensions at 30-degree angles; the vertical axis is drawn vertically and the horizontal axes at 30 degrees.

  • A plumbing plan shows the building layout with pipe runs, fixture locations, and riser diagrams; the riser diagram shows vertical relationships and sizes.

  • Pipe sizes on drawings are given as nominal diameter; symbols for valves, cleanouts, and vents must be read from the legend.

  • Slope is indicated by a note such as '1/4 inch per foot' or a slope symbol; the direction of flow is shown by arrows.

  • Elevations are given in feet and inches above a datum; invert elevations are the inside bottom of the pipe at a given point.

  • A floor plan must be cross-referenced with the structural and architectural plans to avoid conflicts with beams and footings.

  • Drawing scales must be checked against the scale bar; dimensions govern over scaled measurements.

  • The plumbing plan must show the building sewer, water service, and vent termination; the site plan shows the connection to the public main.

  • Isometric drawings are used for complex piping layouts; the drawing must show all valves, cleanouts, and changes in direction.