Pancyprian TS Elec. Eng. III ΘΚ study plan
Pancyprian TS Elec. Eng. III ΘΚ · Give each week a clear focus.
8 weeks · About 6 hours per week
Electrical circuits and network analysis (DC and AC)
Set up a formula sheet for DC circuit laws (Ohm, Kirchhoff's voltage and current laws, series/parallel reduction, voltage and current dividers) and apply it to at least 15 solved numerical problems.
Solve mesh-analysis and nodal-analysis problems on networks with two sources or fewer, checking each answer by a second method.
Compute Thevenin and Norton equivalents for at least 6 circuits containing independent sources and one controlled source, and state the load for maximum power transfer.
Explain in writing when superposition applies and demonstrate it on 3 circuits with two independent sources.
Your checkpoint
A hand-written or typed problem portfolio of 20 fully worked DC network problems, each with a labelled circuit sketch, the method chosen, and a verification step.
Electrical circuits and network analysis (DC and AC)
Convert between time-domain and phasor representations for sinusoidal quantities and compute impedance of R, L and C combinations at a stated frequency.
Solve series and parallel AC circuits using phasors, and calculate real, reactive and apparent power plus power factor for each.
Draw and interpret phasor diagrams for at least 3 circuits, showing the phase relationship between supply voltage and current.
Analyse a balanced three-phase star and delta load, computing line and phase currents and total power.
Your checkpoint
A one-page AC summary sheet (impedance, phasor rules, power triangle, three-phase relations) plus 10 solved AC problems, at least 3 of them three-phase.
Electrical machines and transformers
Derive and use the transformer EMF equation, and calculate turns ratio, secondary voltage and current for ideal and practical transformers.
Compute equivalent resistance and reactance referred to primary and secondary, and use them to estimate regulation at a stated load power factor.
Describe the tests used to obtain transformer parameters (open-circuit and short-circuit tests) and state which losses each test represents.
Solve problems on DC machine EMF and torque equations, and on induction motor slip, synchronous speed and rotor frequency.
Your checkpoint
A worked transformer design-check calculation: given rated kVA, voltages and test data, produce full equivalent circuit parameters referred to one side and the predicted efficiency at 50% and 100% load.
Electrical machines and transformers & Electrical installations and wiring regulations
Compare starting methods for induction motors (direct-on-line, star-delta, autotransformer, soft starter) and select the appropriate one for 3 stated load and supply scenarios.
Interpret a motor nameplate fully, including duty, insulation class, IP rating and connection, and state what each entry constrains.
Apply cable current-carrying capacity, derating factors and voltage-drop limits to select a conductor size for 4 given circuits.
Identify the purpose of protective devices and the required disconnection times for final circuits in the relevant wiring regulation framework.
Your checkpoint
A cable-sizing worksheet covering 4 circuits, showing design current, protective device rating, correction factors, selected conductor size and calculated voltage drop against the permitted limit.
Electrical installations and wiring regulations & Protection, earthing and electrical safety
Classify earthing systems (TN-S, TN-C-S, TT, IT) and state the fault path, protective device relied upon and key hazard for each.
Calculate earth-fault loop impedance and verify that the protective device will disconnect within the required time for 3 example installations.
Specify residual current device ratings and types for given applications, including discrimination between series devices.
Explain equipotential bonding and the role of main and supplementary bonding in limiting touch voltage.
Your checkpoint
An earthing and protection report for a small installation: chosen earthing system, loop impedance calculation, protective device selection with disconnection time check, and RCD schedule.
Power electronics and motor drives
Explain the conduction states and switching behaviour of diodes, thyristors and IGBTs, and match each device to a suitable application.
Analyse single-phase half-wave and full-wave rectifiers with resistive and inductive loads, calculating average and RMS output voltage and ripple.
Describe the principle of pulse-width modulation and compute duty cycle, average output voltage and ripple for a buck converter.
Compare variable-frequency drive control strategies (voltage/frequency, vector control) and state where each is appropriate.
Your checkpoint
A drive selection note for 3 industrial loads (pump, conveyor, hoist), each with the chosen converter topology, control method, justification and a worked duty-cycle or rectifier calculation.
Electrical measurements, instrumentation and testing & Generation, transmission and distribution of electrical energy
Select instruments for measuring voltage, current, power and resistance, and state the effect of meter loading and burden on the reading.
Compute the uncertainty of a measurement that combines several instrument readings, and identify which reading dominates.
Describe the purpose and procedure of insulation resistance, continuity and earth electrode resistance tests, including safe isolation before testing.
Outline the structure of a generation-transmission-distribution system and explain why high voltage is used for bulk transmission.
Your checkpoint
A test schedule and measurement plan for one installation, listing each test, the instrument, the expected result, the acceptance criterion and the dominant uncertainty source.
Technical drawing, schematics and documentation & Electrical circuits and network analysis (DC and AC) & Electrical machines and transformers & Electrical installations and wiring regulations & Power electronics and motor drives & Electrical measurements, instrumentation and testing & Protection, earthing and electrical safety & Generation, transmission and distribution of electrical energy
Read and produce schematic and wiring diagrams using standard symbols, and cross-reference them to a component list.
Complete two timed mock papers under exam conditions and mark them against the official answer key or a self-built rubric.
Rank your weakest three sub-topics from the mock results and rework 5 problems in each.
Consolidate all formula sheets into a single revision sheet you can reproduce from memory.
Your checkpoint
A full timed mock exam result with a scored breakdown by domain, plus a written list of the three weakest sub-topics and the corrective problems solved.
Milestones
Week 2: Without notes, solve one DC network problem and one AC phasor problem correctly in under 15 minutes each.
Week 4: Score at least 70% on a self-made 20-question test covering machines and cable sizing, and correctly size a cable for an unseen circuit.
Week 6: Explain the chosen earthing system and protective device for an unseen installation, and complete a rectifier or converter calculation without reference material.
Week 8: Achieve at least 65% overall on a full timed mock paper with no domain scoring below 50%.