Pancyprian TS Elec. Eng. III ΘΚ study materials
Pancyprian TS Elec. Eng. III ΘΚ study resources

Pancyprian TS Elec. Eng. III ΘΚ study plan

Pancyprian TS Elec. Eng. III ΘΚ · Give each week a clear focus.

8 weeks · About 6 hours per week

Week 1

Electrical circuits and network analysis (DC and AC)

  • Set up a formula sheet for DC circuit laws (Ohm, Kirchhoff's voltage and current laws, series/parallel reduction, voltage and current dividers) and apply it to at least 15 solved numerical problems.

  • Solve mesh-analysis and nodal-analysis problems on networks with two sources or fewer, checking each answer by a second method.

  • Compute Thevenin and Norton equivalents for at least 6 circuits containing independent sources and one controlled source, and state the load for maximum power transfer.

  • Explain in writing when superposition applies and demonstrate it on 3 circuits with two independent sources.

Your checkpoint

A hand-written or typed problem portfolio of 20 fully worked DC network problems, each with a labelled circuit sketch, the method chosen, and a verification step.

Week 2

Electrical circuits and network analysis (DC and AC)

  • Convert between time-domain and phasor representations for sinusoidal quantities and compute impedance of R, L and C combinations at a stated frequency.

  • Solve series and parallel AC circuits using phasors, and calculate real, reactive and apparent power plus power factor for each.

  • Draw and interpret phasor diagrams for at least 3 circuits, showing the phase relationship between supply voltage and current.

  • Analyse a balanced three-phase star and delta load, computing line and phase currents and total power.

Your checkpoint

A one-page AC summary sheet (impedance, phasor rules, power triangle, three-phase relations) plus 10 solved AC problems, at least 3 of them three-phase.

Week 3

Electrical machines and transformers

  • Derive and use the transformer EMF equation, and calculate turns ratio, secondary voltage and current for ideal and practical transformers.

  • Compute equivalent resistance and reactance referred to primary and secondary, and use them to estimate regulation at a stated load power factor.

  • Describe the tests used to obtain transformer parameters (open-circuit and short-circuit tests) and state which losses each test represents.

  • Solve problems on DC machine EMF and torque equations, and on induction motor slip, synchronous speed and rotor frequency.

Your checkpoint

A worked transformer design-check calculation: given rated kVA, voltages and test data, produce full equivalent circuit parameters referred to one side and the predicted efficiency at 50% and 100% load.

Week 4

Electrical machines and transformers & Electrical installations and wiring regulations

  • Compare starting methods for induction motors (direct-on-line, star-delta, autotransformer, soft starter) and select the appropriate one for 3 stated load and supply scenarios.

  • Interpret a motor nameplate fully, including duty, insulation class, IP rating and connection, and state what each entry constrains.

  • Apply cable current-carrying capacity, derating factors and voltage-drop limits to select a conductor size for 4 given circuits.

  • Identify the purpose of protective devices and the required disconnection times for final circuits in the relevant wiring regulation framework.

Your checkpoint

A cable-sizing worksheet covering 4 circuits, showing design current, protective device rating, correction factors, selected conductor size and calculated voltage drop against the permitted limit.

Week 5

Electrical installations and wiring regulations & Protection, earthing and electrical safety

  • Classify earthing systems (TN-S, TN-C-S, TT, IT) and state the fault path, protective device relied upon and key hazard for each.

  • Calculate earth-fault loop impedance and verify that the protective device will disconnect within the required time for 3 example installations.

  • Specify residual current device ratings and types for given applications, including discrimination between series devices.

  • Explain equipotential bonding and the role of main and supplementary bonding in limiting touch voltage.

Your checkpoint

An earthing and protection report for a small installation: chosen earthing system, loop impedance calculation, protective device selection with disconnection time check, and RCD schedule.

Week 6

Power electronics and motor drives

  • Explain the conduction states and switching behaviour of diodes, thyristors and IGBTs, and match each device to a suitable application.

  • Analyse single-phase half-wave and full-wave rectifiers with resistive and inductive loads, calculating average and RMS output voltage and ripple.

  • Describe the principle of pulse-width modulation and compute duty cycle, average output voltage and ripple for a buck converter.

  • Compare variable-frequency drive control strategies (voltage/frequency, vector control) and state where each is appropriate.

Your checkpoint

A drive selection note for 3 industrial loads (pump, conveyor, hoist), each with the chosen converter topology, control method, justification and a worked duty-cycle or rectifier calculation.

Week 7

Electrical measurements, instrumentation and testing & Generation, transmission and distribution of electrical energy

  • Select instruments for measuring voltage, current, power and resistance, and state the effect of meter loading and burden on the reading.

  • Compute the uncertainty of a measurement that combines several instrument readings, and identify which reading dominates.

  • Describe the purpose and procedure of insulation resistance, continuity and earth electrode resistance tests, including safe isolation before testing.

  • Outline the structure of a generation-transmission-distribution system and explain why high voltage is used for bulk transmission.

Your checkpoint

A test schedule and measurement plan for one installation, listing each test, the instrument, the expected result, the acceptance criterion and the dominant uncertainty source.

Week 8

Technical drawing, schematics and documentation & Electrical circuits and network analysis (DC and AC) & Electrical machines and transformers & Electrical installations and wiring regulations & Power electronics and motor drives & Electrical measurements, instrumentation and testing & Protection, earthing and electrical safety & Generation, transmission and distribution of electrical energy

  • Read and produce schematic and wiring diagrams using standard symbols, and cross-reference them to a component list.

  • Complete two timed mock papers under exam conditions and mark them against the official answer key or a self-built rubric.

  • Rank your weakest three sub-topics from the mock results and rework 5 problems in each.

  • Consolidate all formula sheets into a single revision sheet you can reproduce from memory.

Your checkpoint

A full timed mock exam result with a scored breakdown by domain, plus a written list of the three weakest sub-topics and the corrective problems solved.

Milestones

Week 2: Without notes, solve one DC network problem and one AC phasor problem correctly in under 15 minutes each.

Week 4: Score at least 70% on a self-made 20-question test covering machines and cable sizing, and correctly size a cable for an unseen circuit.

Week 6: Explain the chosen earthing system and protective device for an unseen installation, and complete a rectifier or converter calculation without reference material.

Week 8: Achieve at least 65% overall on a full timed mock paper with no domain scoring below 50%.