- DC contractor license expiration
- DC contractor licenses expire on August 31 of even-numbered years. Renewal requires continuing education and payment of fees before the expiration date to avoid a lapse.
- DC general contractor bond
- A DC general contractor license requires a $25,000 surety bond filed with DLCP. The bond protects consumers from certain violations of the licensing law.
- Home improvement contract threshold
- In DC, home improvement contracts for $300 or more must be written and signed. The contract must include the license number, scope, dates, and cancellation notice.
- Three-day cancellation right
- DC home improvement buyers may cancel a contract within three business days of signing. The contractor must give written notice of this right at signing.
- Wage payment frequency
- DC's Wage Payment Act requires employers to pay wages at least twice per month. The final paycheck is due on the next regular payday after separation.
- Workplace Fraud Amendment Act
- DC law presumes workers are employees unless the employer proves the ABC test. Misclassification can trigger penalties, back wages, and license suspension.
- Prompt Payment Act timing
- DC's Prompt Payment Act requires owners to pay prime contractors within 15 days of a proper invoice. Primes must pay subs within 7 days of receipt.
- DC minimum wage indexing
- DC's Minimum Wage Revision Act indexes the minimum wage annually to inflation. The Living Wage Act sets higher rates for covered government contracts.
- License number display rule
- DC licensed contractors must display their license number on advertisements, contracts, permits, and business vehicles. Failure to display is a fineable violation.
- DLCP licensing authority
- The Department of Licensing and Consumer Protection (DLCP), formerly DCRA, issues and enforces DC contractor licenses and investigates consumer complaints against contractors.
- DC continuing education requirement
- DC contractors must complete 8 hours of continuing education per two-year license cycle. The coursework includes DC-specific code and business topics.
- DC Construction Codes basis
- DC adopts the International Code Council family of codes with local amendments. The DC Green Building Act applies to projects over 50,000 square feet.
- Concrete 28-day strength
- Concrete compressive strength is verified at 28 days per ACI 318. Standard cylinders are tested at 7 and 28 days; residential slabs typically require 2,500 psi minimum.
- Joist notching limits
- IRC limits joist notching to one-sixth of the member depth. Boring is limited to one-third of depth and never within 2 inches of top or bottom edges.
- Egress window dimensions
- Emergency escape windows require 5.7 square feet net clear opening. Minimum dimensions are 24 inches high by 20 inches wide with a 44-inch maximum sill height.
- OSHA Focus Four hazards
- The Focus Four are falls, struck-by, caught-in/between, and electrical hazards. They cause the majority of construction fatalities and are the focus of OSHA training.
- Fall protection trigger height
- OSHA requires fall protection in construction at 6 feet or more. Acceptable systems include guardrails, safety nets, and personal fall arrest systems.
- Stair riser and tread limits
- IRC limits riser height to 7.75 inches and requires tread depth of at least 10 inches. Headroom must be at least 6 feet 8 inches.
- Handrail height range
- IRC requires handrails on at least one side of stairs, with height between 34 and 38 inches measured vertically from the stair nosing.
- GFCI protection locations
- GFCI protection is required in bathrooms, kitchens, garages, outdoors, and within 6 feet of sinks. It protects against shock from ground faults.
- AFCI protection scope
- AFCI protection is required for most 120-volt branch circuits in dwelling units under current NEC editions. It detects arc faults that can start fires.
- Trap arm slope
- Plumbing trap arms for pipes 2 inches or smaller must slope at least 1/4 inch per foot. Larger pipes may slope at 1/8 inch per foot.
- Water closet clearances
- Water closets require at least 15 inches of center-to-side clearance and 21 inches of clearance in front. These dimensions ensure usable and code-compliant fixtures.
- Trench protective system rule
- Trenches 5 feet or deeper require a protective system unless entirely in stable rock. A competent person must inspect daily and after rain.
- Competent person definition
- A competent person is capable of identifying hazards and authorized to take prompt corrective action. OSHA requires one for excavations and scaffolding.
- Scaffold guardrail requirements
- Scaffolds over 10 feet require guardrails and toeboards. The top rail is installed between 38 and 45 inches above the platform.
- Ladder angle rule
- Extension ladders must be set at a 4:1 ratio, meaning 1 foot of base offset for every 4 feet of working height. Ladders must extend 3 feet above the landing.
- Concrete formwork removal
- Formwork for structural members may be removed when concrete has attained sufficient strength. Typically, slab forms are removed at 7 days and beam forms at 14 days.
- Damp-proofing versus waterproofing
- Damp-proofing resists moisture vapor and is applied to foundation walls. Waterproofing resists hydrostatic pressure and is required where groundwater is present.
- Fire-resistance rating assembly
- Fire-resistance ratings are expressed in hours and verified by tested assemblies. Common ratings are 1-hour and 2-hour walls, floors, and shaft enclosures.
- Energy code envelope requirement
- The IECC sets minimum insulation R-values and window U-factors. DC amends the IECC and enforces envelope, HVAC, and lighting efficiency requirements.
- Site plan review submission
- DC permit applications require a site plan, construction drawings, and a plat. Plans must be sealed by a licensed architect or engineer for commercial work.