Dell VxRail Deploy study materials
Dell VxRail Deploy study resources

Dell VxRail Deploy cheat sheet

Dell VxRail Deploy · Keep the key ideas within reach.

Quick reference

VxRail Deployment Planning

  • VxRail is a hyperconverged system co-engineered by Dell and VMware; each node runs ESXi with vSAN providing the distributed datastore, and VxRail Manager runs as a VM on the cluster.

  • Minimum viable cluster is 3 nodes; 2-node clusters require a witness appliance placed at a third site or fault domain, and stretched clusters use 2+2 nodes plus a witness.

  • All nodes in a VxRail cluster must be the same model and same or comparable drive configuration; mixing models within one cluster is not supported for initial build.

  • Sizing rule: usable vSAN capacity = raw capacity minus vSAN overhead, minus the failure tolerance (FTT=1 reserves one copy equivalent), minus ~30% free-space headroom target.

  • RAID-5 erasure coding in vSAN requires a minimum of 4 nodes; RAID-6 requires a minimum of 6 nodes; below those thresholds FTT is achieved with RAID-1 mirroring.

  • Network planning: separate VLANs for management, vMotion, vSAN, VM traffic, and VxRail Manager; 10 GbE minimum per node, 25 GbE recommended for all-flash.

  • VxRail Manager must resolve by FQDN from every node and from the deployment client; DNS records and PTR records for all management addresses are prerequisites.

  • The deployment client (browser host) must reach VxRail Manager and the ESXi management addresses; a flat L2 path or routed access with correct firewall openings is required.

  • NTP is mandatory: one or more reachable NTP sources must be defined so that vCenter, ESXi, and VxRail Manager stay time-synchronized; external vCenter is supported for VxRail 7.x and later.

Quick reference

VxRail Hardware Installation and Configuration

  • Rack nodes front-to-back with cold aisle at the front; leave 1U of clearance above and below for airflow if the rack permits, and install rails before lifting the chassis.

  • Power each node from redundant PDUs on separate feeds; the PSUs are hot-swappable and each node should draw from both A and B feeds.

  • Connect the iDRAC (or equivalent BMC) port to the management network first; iDRAC gives remote console and virtual media access for the rest of the build.

  • Set iDRAC IPs statically or via DHCP reservation before power-on; each node needs a unique management IP and hostname that matches DNS.

  • Boot order and boot device: VxRail uses a dedicated boot device (BOSS card or M.2 RAID-1) separate from vSAN capacity and cache drives; confirm the boot device is healthy before install.

  • vSAN cache tier: one cache drive per disk group; all-flash nodes use write-buffer semantics, hybrid nodes use read/write cache; disk groups are created by the VxRail build process.

  • Cabling: use the supported SFP+/SFP28 optics and DAC cables for the model; uplinks typically go to a pair of top-of-rack switches in a redundant topology (LACP or active/standby).

  • Verify hardware health in iDRAC (PSU, fans, memory, drives) before starting the VxRail deployment; a failed drive or PSU will halt or degrade the build.

  • Firmware baseline: VxRail bundles a validated firmware/software bundle; do not upgrade individual components outside the VxRail bundle unless directed by support.

Quick reference

VxRail Cluster Deployment and Network Configuration

  • Deployment flow: power on nodes, access VxRail Manager via the initial wizard (Mystic), supply vCenter credentials, network settings, and the VxRail bundle, then let the automated build run.

  • VxRail Manager initial access uses a temporary bootstrap address; the permanent address and FQDN are set during the wizard and must match DNS.

  • The vCenter used may be the embedded VxRail vCenter (VxRail-managed) or an external customer-supplied vCenter; external vCenter requires the correct permissions and version compatibility.

  • VDS (vSphere Distributed Switch) is the default networking model for VxRail 7.x; standard vSwitch is used only in specific/legacy configurations.

  • Uplink assignment: map physical NICs to VDS uplinks, then create port groups for management, vMotion, vSAN, and VM networks with the correct VLAN IDs.

  • MTU: vSAN and vMotion port groups typically use jumbo frames (MTU 9000); the entire L2 path (physical switches, VDS, VMkernel) must match or frames are dropped.

  • IP pool planning: each VMkernel service needs its own IP per node; reserve contiguous ranges for vSAN and vMotion VMkernels before running the wizard.

  • Stretched and 2-node clusters require witness traffic separation: a dedicated witness VMkernel and VLAN, and the witness appliance placed at a third site.

  • Post-build validation: confirm cluster health in VxRail Manager, vSAN health in vCenter, all nodes in the cluster, and no configuration drift in the VxRail plugin.

Quick reference

VxRail Post-Deployment Operations and Troubleshooting

  • VxRail Manager is the single pane for lifecycle: bundle upgrades, health checks, and log bundles; the VxRail plugin surfaces this inside vCenter.

  • Upgrade order for a VxRail bundle: VxRail Manager pre-checks, then vCenter (if embedded), then ESXi nodes one at a time (vSAN rebuild between nodes), then VxRail Manager itself.

  • Before any upgrade, run the VxRail pre-upgrade health check and confirm no degraded vSAN objects, no failed disks, and sufficient free capacity for rebuilds.

  • Log collection: use the VxRail Manager log bundle (or the CLI) to gather ESXi, vCenter, and VxRail Manager logs for support; the bundle is the standard first troubleshooting artifact.

  • vSAN health in vCenter: check cluster > monitor > vSAN > health for object health, disk balance, and network checks; a failing network check points to MTU or VLAN mismatch.

  • Node replacement: put the node in maintenance mode with 'ensure accessibility' or 'full data migration' depending on capacity; full migration requires enough free space to rebuild.

  • VxRail Manager unreachable: verify the VxRail Manager VM is powered on in vCenter, check its IP/DNS, and confirm the plugin service is running; a common cause is a DNS or certificate change.

  • Configuration drift: if the VxRail plugin reports drift, run the reconcile/resync operation from VxRail Manager rather than editing vCenter objects manually.

  • Capacity alerts: monitor vSAN capacity and the VxRail 'cluster expansion' readiness; add a node or expansion shelf before usable capacity drops below the rebuild reserve.