Egypt Engineering Consultant Mechanical · Give each week a clear focus.

8 weeks · About 7 hours per week

Week 1

HVAC and Refrigeration Systems Design & Thermodynamics, Heat Transfer and Fluid Mechanics

  • Derive the psychrometric process path (sensible heat ratio, apparatus dew point, bypass factor) for three sample cooling-coil cases and calculate supply air volume flow for each.

  • Compute room cooling and heating loads by assembling a manual load sheet covering conduction, solar gain, internal gains, and ventilation/infiltration, then cross-check the total against a rule-of-thumb estimate.

  • Size duct mains and branches using the equal-friction and velocity-reduction methods, and verify static pressure drop across the longest run including fittings.

  • Explain how refrigerant pressure-enthalpy diagrams map to compressor, condenser, evaporator, and expansion device selection, and calculate COP for two operating points.

  • Solve five fluid-mechanics problems on duct and pipe friction (Darcy-Weisbach, Moody chart) and pump/fan affinity laws.

Your checkpoint

A single worked calculation pack (8-12 pages) containing one complete cooling load sheet, one duct sizing table with pressure drop totals, and one refrigeration cycle calculation with annotated P-h sketch.

Week 2

HVAC and Refrigeration Systems Design

  • Select chiller type (air-cooled vs water-cooled, centrifugal vs screw vs scroll) for three building scenarios and justify each choice on part-load efficiency and condenser water availability.

  • Lay out a chilled water distribution scheme with primary/secondary pumping, and size the expansion tank and pump heads.

  • Design a ventilation strategy for a commercial kitchen, a car park, and an office floor, calculating fresh-air rates and exhaust balances for each.

  • Compare constant air volume and variable air volume systems on energy use and control complexity for a mid-rise office, and specify terminal units.

  • Check a refrigerant quantity and occupied-space concentration limit against safety classification for a direct-expansion system.

Your checkpoint

A design basis document for a hypothetical 10-storey office tower: system selection matrix, chilled water schematic, and ventilation schedule with calculated airflow rates.

Week 3

Plumbing, Drainage and Fire Protection Systems & Engineering Codes, Standards and Egyptian Regulations

  • Size cold water supply pipes and storage tanks for a mixed-use building using fixture unit loading and demand curves, showing the calculation steps.

  • Design soil, waste, and vent stacks for a multi-storey building, checking stack capacity, trap arm lengths, and vent sizing.

  • Lay out a fire sprinkler and standpipe system for a warehouse and an office floor, calculating hazard classification, design density, and pump duty.

  • Identify the governing Egyptian code requirements and authority approval path for water supply, drainage, and fire protection submissions, and list the documents each authority expects.

  • Compare local code provisions with widely referenced international standards on one topic (e.g., sprinkler design density) and note where the stricter requirement governs.

Your checkpoint

A plumbing and fire protection design package: riser diagrams for water, drainage, and sprinkler systems, plus a one-page code-compliance matrix citing clause references.

Week 4

Mechanical Power Systems and Energy Conversion & Thermodynamics, Heat Transfer and Fluid Mechanics

  • Evaluate prime mover options (diesel generator, gas engine, turbine, grid supply) for a facility load profile and calculate fuel consumption and annual operating cost for each.

  • Compute heat exchanger duty and effectiveness for a shell-and-tube and a plate unit using the log-mean temperature difference and effectiveness-NTU methods.

  • Analyze a simple gas turbine or Rankine cycle: calculate thermal efficiency, specific work, and the effect of regeneration or reheat.

  • Size a compressed air system including receiver volume, dryer selection, and distribution pressure drop for a workshop load.

  • Interpret a pump and system curve intersection and determine the effect of throttling versus variable speed control on power.

Your checkpoint

An energy conversion comparison report with a load duration curve, three prime-mover cost tables, and two fully worked cycle/heat-exchanger problems with conclusions.

Week 5

Electrical, Control and Building Automation Interfaces & HVAC and Refrigeration Systems Design

  • Specify the control sequence of operation for an air handling unit and a chilled water plant, writing each sequence in plain narrative with setpoints and fail-safe positions.

  • Map mechanical equipment to electrical loads: calculate motor full-load current, starting method, protection coordination needs, and generator/ATS interface for chillers and fire pumps.

  • Define the points list and network architecture (BACnet/IP backbone, field bus, gateways) for a building automation system covering HVAC, plumbing, and fire interfaces.

  • Explain fire alarm and fire pump interface requirements with HVAC shutdown, damper control, and smoke management, and identify the signals that must be hard-wired.

  • Review a sample control schematic and mark up three errors in sensor placement, valve failure position, or interlock logic.

Your checkpoint

A controls specification section with sequences of operation for two systems, a points schedule of at least 40 points, and a marked-up schematic showing corrections.

Week 6

Engineering Codes, Standards and Egyptian Regulations & Health, Safety and Environmental Practice

  • Build a personal index of the Egyptian codes and ministerial decrees relevant to mechanical works, recording issuing body, scope, and where each is referenced in a submission.

  • Outline the approval workflow from design to occupancy for a new building, naming the authorities and the mechanical inspections at each stage.

  • Perform a hazard identification and risk assessment for a plant room (refrigerant, fuel, electrical, confined space) and assign controls by hierarchy.

  • Specify refrigerant safety measures, ventilation rates, gas detection, and emergency shutdown for a machine room, and check against the applicable standard.

  • Draft a waste management and environmental controls plan for a construction site covering dust, noise, and refrigerant recovery.

Your checkpoint

A compliance and HSE handbook (10-15 pages): code index table, approval flowchart, one completed risk assessment with hierarchy-of-controls matrix, and a site environmental plan.

Week 7

Project Management, Contracts and Cost Estimation & Professional Ethics, Liability and Consultant Practice

  • Prepare a quantity take-off and cost estimate for a mechanical package (HVAC and plumbing) with rates, preliminaries, contingency, and escalation.

  • Compare lump-sum, remeasured, and design-build contract forms on risk allocation for the consultant, and identify clauses that shift design liability.

  • Draft a variation and claim assessment for a delayed equipment delivery, showing time impact and cost build-up.

  • Analyze three ethics scenarios (conflict of interest in specification, pressure to certify non-compliant work, unpaid fee and withholding of documents) and state the correct professional response.

  • Define the consultant's standard of care, professional indemnity coverage, and record-keeping that supports a defense against a negligence claim.

Your checkpoint

A contract and ethics file: one cost estimate with take-off backup, one claim assessment memo, and three written ethics case responses each ending in a defensible action plan.

Week 8

HVAC and Refrigeration Systems Design & Plumbing, Drainage and Fire Protection Systems & Thermodynamics, Heat Transfer and Fluid Mechanics & Mechanical Power Systems and Energy Conversion & Electrical, Control and Building Automation Interfaces & Engineering Codes, Standards and Egyptian Regulations & Project Management, Contracts and Cost Estimation & Health, Safety and Environmental Practice & Professional Ethics, Liability and Consultant Practice

  • Sit two full-length timed mock exams under exam conditions and record the score by domain to expose weak areas.

  • Re-work every missed item from the mocks to root cause (knowledge gap, misread, calculation error) and close each gap with a targeted reference check.

  • Recite from memory the key design values, code thresholds, and safety limits you are most likely to be tested on, and verify each against source.

  • Rehearse a 10-minute verbal defense of one design decision in each of HVAC, plumbing/fire, and power systems as if presenting to an approving authority.

  • Assemble a one-page personal formula and reference sheet for final review.

Your checkpoint

A mock exam scorecard with domain breakdown, a closed-gap list showing every corrected item, and a final one-page formula/reference sheet.

Milestones

Week 2: Can complete a full cooling load and duct sizing calculation unaided within 90 minutes, and justify system selection for a given building brief in writing.

Week 4: Scores at least 65% on a self-made 40-question set covering domains 1-4, with plumbing/fire riser diagrams and a code matrix already produced.

Week 6: Can name the authority and approval stage for each mechanical submission without notes, and has a completed risk assessment that passes self-review against the hierarchy of controls.

Week 7: Produces a mechanical cost estimate within 15% of a benchmark and articulates the consultant's liability position in two contract scenarios.

Week 8: Mock exam average at or above 70% overall with no domain below 60%, and every missed item closed with a documented correction.