EPA 608 study plan
EPA 608 · Give each week a clear focus.
8 weeks · About 6 hours per week
Universal (Types I, II, and III) & Type I - Small Appliances
Define ozone depletion potential (ODP) and global warming potential (GWP) and rank CFCs, HCFCs, HFCs, and HFOs by each metric
State the Clean Air Act venting prohibition and name the four permitted exceptions for knowingly releasing refrigerant
Identify the Section 608 certification categories and the sale, purchase, and recordkeeping rules that apply to refrigerant and recovery equipment
Distinguish recovery, recycling, and reclamation and name where each may legally occur
Recognize the definition and examples of a small appliance (hermetic, factory-sealed, 5 lb charge or less) and the recovery-evacuation level that applies to it
Your checkpoint
Closed-book 40-question Core + Type I quiz scored at 80% or higher, with every missed item logged alongside the correct rule.
Type II - High-Pressure Appliances
Explain why high-pressure systems are recovered liquid first, then vapor, and describe the equipment setup for each phase
Apply recovery cylinder rules: the 80% fill limit, DOT marking, requalification intervals, and safe transfer procedures
Apply the evacuation level table by appliance type and charge size (0 psig, 10 in Hg vacuum, 25 mm Hg absolute)
Select the correct recovery machine, hoses, and cylinder for R-410A and other high-pressure blends
Describe the standing vacuum and vacuum-decay tests used to confirm a leak-free, moisture-free system
Your checkpoint
A one-page evacuation-level reference sheet reproduced from memory plus a 30-item evacuation-level drill scored at 90% or higher.
Type II - High-Pressure Appliances & Type I - Small Appliances
Calculate leak rates and match them to the 15%, 20%, and 35% thresholds for industrial process refrigeration, commercial refrigeration, and comfort cooling, including the applicable repair and verification deadlines
Determine when an appliance must be retrofitted or retired instead of repaired
Choose between charging by weight, by subcooling, and by superheat for a given system and explain why the other methods are wrong
Describe the handling differences for R-410A and A2L refrigerants in pressure, lubricant, and leak-detection behavior
List the documentation required when refrigerant is added to or removed from an appliance
Your checkpoint
Type II section simulator (40 questions) scored at 85% or higher, supported by a five-scenario leak-rate calculation worksheet showing each step.
Type III - Low-Pressure Appliances
Describe the operating characteristics of low-pressure centrifugal chillers, including evaporator pressures below atmospheric and the air/moisture ingress problem
Apply the 25 mm Hg absolute evacuation requirement to low-pressure appliances
Explain the purpose, operation, and efficiency testing of purge units
Describe rupture disc function, relief device settings, and the safe isolation of low-pressure vessels before service
Outline leak detection and charging methods for chillers, including charging refrigerant as a vapor and dehydrating a wet system
Your checkpoint
Type III section simulator scored at 85% or higher plus a text-described logic diagram linking chiller pressure, purge operation, and rupture-disc protection.
Type III - Low-Pressure Appliances & Type II - High-Pressure Appliances
Compare low-pressure and high-pressure recovery and evacuation requirements side by side in a single table
Solve mixed scenarios in which the appliance type, charge size, and manufacture date all change the correct answer
Distinguish system-dependent from self-contained recovery equipment and identify when each is permitted
Explain the purity standards behind recycled versus reclaimed refrigerant and who may perform each
Your checkpoint
Timed 50-question mixed Type II/Type III exam scored at 85% or higher, with the comparison table submitted as the study artifact.
Universal (Types I, II, and III)
Combine Core, Type I, Type II, and Type III rules into single decisions on whole-system scenarios
Identify safety hazards and controls: frostbite, asphyxiation, oxygen displacement, cylinder hydrostatic testing, and overfilling
Recognize refrigerant cylinder markings, colors, DOT transport rules, and storage limits
Apply date-based and refrigerant-based distinctions, including appliances built before and after November 15, 1993, and very high-pressure systems
Your checkpoint
Full-length 80-question Universal practice exam scored at 80% or higher with an item-by-item error log.
Universal (Types I, II, and III) & Type II - High-Pressure Appliances & Type III - Low-Pressure Appliances
Rank weak topics by error frequency from the practice exam log
Re-drill the top three weak topics to 90% accuracy or better
Memorize the numeric threshold table (5 lb, 200 lb, 15/20/35%, 0 psig, 10 in Hg, 25 mm Hg) using spaced recall
Answer 25 questions in 20 minutes to build exam pacing
Your checkpoint
An error log showing every previously missed item answered correctly on two separate attempts.
Universal (Types I, II, and III) & Type I - Small Appliances & Type II - High-Pressure Appliances & Type III - Low-Pressure Appliances
Complete two full-length timed Universal practice exams under test-day conditions
Write a one-line rationale for every flagged or guessed item
Re-verify the numeric thresholds and venting exceptions one final time without notes
Confirm test-day logistics: appointment, identification, and certification paperwork
Your checkpoint
Two consecutive Universal practice exams scored at 90% or higher.
Milestones
Week 2: Core + Type I quiz at 80% or higher, and the evacuation-level reference sheet recreated from memory without errors.
Week 4: Half-length mock covering Domains 1, 2, and 3 scored at 80% or higher.
Week 6: Full-length Universal practice exam at 80% or higher with every error logged and categorized.
Week 8: Two consecutive timed Universal practice exams at 90% or higher.