ESEGH flashcards
ESEGH · Build recall with a focused review session.
33 cards. Read the term and the definition here. The deck at the top of this page is optional.
- Betz limit
- The theoretical maximum fraction of wind kinetic energy an ideal rotor can extract, equal to 16/27 or about 0.593 of the incoming wind power.
- Tip-speed ratio
- The ratio of blade tip speed to wind speed, lambda = omega*R/v. Turbines operate near an optimal value, typically 6 to 8 for three-blade machines.
- Per-unit system
- A normalization method where quantities are divided by base values (Z_base = V_base^2/S_base), making per-unit impedances identical across transformer voltage levels in power flow studies.
- Swing equation
- The differential equation (2H/omega_s)*d2delta/dt2 = P_m - P_e relating generator rotor angle acceleration to the imbalance between mechanical and electrical power.
- Surge impedance loading
- The power a transmission line delivers when its reactive losses equal reactive generation, approximately V_LL^2/Z_c, typically near 400 ohms overhead.
- Droop control
- A governor or inverter control where frequency deviation is proportional to power change, e.g., 5% droop means full power change for a 5% frequency change.
- SAIDI and SAIFI
- Reliability indices: SAIDI is customer-minutes interrupted divided by total customers; SAIFI is customer interruptions divided by total customers.
- PV temperature coefficient
- The rate at which module power decreases per degree Celsius above 25 C STC, typically -0.3% to -0.45% per degree C for crystalline silicon.
- Fill factor
- The ratio of maximum PV power to the product of open-circuit voltage and short-circuit current, FF = P_max/(V_oc*I_sc), indicating cell quality.
- Air mass AM1.5
- The standard solar spectrum reference where sunlight travels 1.5 times the vertical atmospheric path, used for testing and rating PV modules.
- Pumped storage efficiency
- The round-trip efficiency of pumping water uphill and generating on release, typically 70 to 80 percent, making it the largest form of grid storage.
- Coefficient of performance
- The ratio of useful heating or cooling output to electrical input in kilowatts; COP approximately equals EER divided by 3.412.
- Load factor
- The ratio of average load to peak load over a period. Low values indicate peaky consumption and higher per-kWh delivery costs.
- Affinity laws
- For fans and pumps, flow scales with speed, head with speed squared, and power with speed cubed, so reducing speed cuts power sharply.
- Demand response types
- Price-based programs (time-of-use, real-time, critical-peak pricing) and incentive-based programs (direct load control, demand bidding, interruptible tariffs) shift or curtail load.
- IPMVP options
- Measurement and verification options A (retrofit isolation, key parameters), B (retrofit isolation, all parameters), C (whole facility), and D (calibrated simulation).
- U-value and R-value
- U-value is thermal transmittance in W/m2-K; R-value is its reciprocal. Lower U-value and higher R-value indicate better insulation.
- Life-cycle assessment
- A method per ISO 14040/14044 with four stages: goal and scope, inventory analysis, impact assessment, and interpretation, used to quantify environmental burdens.
- Global warming potential
- A factor converting a gas mass to CO2-equivalent over a time horizon; methane GWP100 is about 28 to 30 and nitrous oxide about 265 to 298.
- Grid emission factor
- Total GHG emissions from electricity generation divided by total generation, expressed in kg CO2e per kWh, used for location-based Scope 2 accounting.
- Environmental impact assessment
- A structured process of screening, scoping, baseline study, impact prediction, mitigation design, and monitoring applied before approving major projects.
- LCOE formula
- Levelized cost of energy equals the discounted sum of investment, O&M, and fuel costs divided by discounted energy output, giving a per-kWh lifetime cost.
- Merit order effect
- Low-marginal-cost renewable generation displaces higher-cost plants in dispatch, lowering wholesale electricity prices and shifting the supply curve.
- Net metering vs net billing
- Net metering credits exports at the retail rate; net billing credits exports at avoided cost or wholesale rate, reducing the value of behind-the-meter generation.
- Feed-in tariff
- A policy paying a fixed, above-market price per kWh for renewable generation over a long contract, contrasting with competitive auctions and renewable portfolio standards.
- GHG Protocol scopes
- Scope 1 covers direct emissions, Scope 2 purchased electricity and heat, and Scope 3 all upstream and downstream value-chain emissions.
- Scope 2 dual reporting
- Reporting purchased electricity emissions both location-based (grid average factor) and market-based (contractual instruments such as RECs and PPAs).
- Emission calculation identity
- Emissions equal activity data multiplied by an emission factor, for example kWh times kg CO2e per kWh, or liters of fuel times kg CO2 per liter.
- ISO 14064-1
- The standard specifying principles and requirements for organizational GHG inventories: relevance, completeness, consistency, accuracy, and transparency.
- Climate risk equation
- Climate risk equals hazard multiplied by exposure multiplied by vulnerability, where hazard is the event, exposure the assets at risk, and vulnerability the susceptibility.
- TCFD pillars
- The four disclosure pillars: governance, strategy, risk management, and metrics and targets, covering physical and transition climate risks.
- SSP5-8.5 scenario
- A high-emissions Shared Socioeconomic Pathway used in climate stress testing, representing fossil-fuel-intensive development and strong warming.
- Stranded assets
- Fossil fuel reserves or carbon-intensive infrastructure that may lose value under decarbonization policy, demand shifts, or technology change.