ESEGH: Renewable Energy Technologies

ESEGH · Work through your exam, one topic at a time.

All guide sections

Renewable Energy Technologies

This domain tests conversion physics, resource assessment and performance rating for solar, wind, hydro, geothermal, biomass and heat pumps. Most questions ask you to take a rated value, apply the real-world derates and produce a defensible energy estimate.

Core rules and concepts

  • PV rating conditions. Standard test conditions are 1,000 W/m² irradiance, 25 °C cell temperature and AM 1.5 spectrum. The power temperature coefficient for crystalline silicon is typically -0.25 to -0.45 %/°C, so hot modules lose output even in strong sun.
  • PV system losses. The performance ratio, usually 0.75-0.85, bundles soiling, mismatch, wiring, inverter and availability losses. Bifacial modules add a 5-15% rear-side gain depending on albedo and mounting height; single-axis tracking adds a further 15-25% over fixed tilt in high-DNI sites.
  • Wind physics. Power in the wind is 0.5·ρ·A·v³. The Betz limit is 16/27, about 59.3%; modern turbines reach Cp of 0.35-0.50. Typical cut-in is 3 m/s, rated power at 11-14 m/s, cut-out at 25 m/s. Because output scales with the cube of speed, a 10% wind resource error is a 33% energy error.
  • Resource extrapolation. Hub-height wind is estimated from measured height using a shear exponent, commonly 0.10-0.25 offshore and land, and 0.14 for the one-seventh power law. Wake losses of 5-15% apply within arrays.
  • Other technologies. Hydro output is proportional to head times flow. CSP with thermal storage is dispatchable and has a high capacity credit. Geothermal runs at 85-95% capacity factor. A heat pump with COP 3-4 delivers three to four units of heat per unit of electricity.

Worked example

A 450 W module with a -0.35 %/°C power coefficient operates at 55 °C cell temperature under 900 W/m² plane-of-array irradiance. Irradiance factor = 900/1,000 = 0.90. Temperature derate = (55 - 25) × -0.35% = -10.5%, so the factor is 0.895. Output = 450 × 0.90 × 0.895 ≈ 362 W. Adding a 97% inverter efficiency and 3% wiring loss gives roughly 341 W at the meter, about 76% of nameplate.

Traps that cost marks

  • Using ambient air temperature instead of cell temperature; cells run 20-30 °C above ambient at full sun.
  • Applying the temperature coefficient to irradiance changes as well as temperature.
  • Quoting the Betz limit as an achieved efficiency.
  • Extrapolating wind speed with the wrong shear exponent or from the wrong measurement height.
  • Comparing capacity factors across technologies without noting dispatchability and firmness.